This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.102A
0.518
74.106%
0.075
5.110V
0.699
115.07V
2
0.252A
1.284
78.725%
0.162
5.104V
1.631
115.07V
3
1.002A
5.081
80.281%
0.377
5.071V
6.329
115.07V
4
3.002A
14.979
78.891%
0.495
4.990V
18.987
115.07V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
8.020A
1.983A
1.985A
0.986A
119.805
87.769%
769
27.4
38.52°C
0.982
12.246V
5.049V
3.323V
5.055V
136.500
43.85°C
115.10V
2
17.064A
2.969A
2.978A
1.190A
239.650
90.853%
1007
33.6
39.35°C
0.984
12.235V
5.049V
3.321V
5.036V
263.777
44.89°C
115.09V
3
26.481A
3.466A
3.494A
1.395A
359.845
91.406%
1349
42.1
39.98°C
0.989
12.226V
5.048V
3.319V
5.015V
393.679
45.86°C
115.08V
4
35.898A
3.964A
3.976A
1.600A
479.643
91.147%
1808
51.2
40.88°C
0.993
12.214V
5.047V
3.317V
4.994V
526.233
46.61°C
115.09V
5
44.991A
4.959A
4.974A
1.806A
599.565
90.641%
2061
52.4
41.67°C
0.995
12.204V
5.046V
3.315V
4.974V
661.470
48.01°C
115.10V
6
54.110A
5.943A
5.975A
2.015A
719.468
90.181%
2061
52.4
42.55°C
0.996
12.192V
5.046V
3.312V
4.953V
797.804
49.46°C
115.10V
7
63.229A
6.938A
6.978A
2.229A
839.365
89.649%
2061
52.4
43.70°C
0.997
12.182V
5.047V
3.310V
4.933V
936.282
51.95°C
115.11V
8
72.369A
7.925A
7.977A
2.441A
959.236
88.859%
2061
52.4
44.37°C
0.997
12.172V
5.047V
3.307V
4.909V
1079.504
53.82°C
115.12V
9
81.963A
8.433A
8.501A
2.448A
1079.285
88.017%
2061
52.4
45.23°C
0.998
12.160V
5.043V
3.305V
4.898V
1226.225
55.72°C
115.12V
10
91.313A
8.928A
8.991A
3.084A
1199.062
87.030%
2061
52.4
45.52°C
0.998
12.149V
5.043V
3.303V
4.857V
1377.763
56.76°C
115.12V
11
101.360A
8.937A
8.999A
3.091A
1319.107
86.320%
2061
52.4
45.58°C
0.998
12.129V
5.038V
3.300V
4.850V
1528.165
58.01°C
115.11V
CL1
0.099A
15.019A
15.006A
0.005A
127.176
84.037%
1349
42.1
39.53°C
0.991
12.256V
5.074V
3.314V
5.081V
151.333
44.95°C
115.11V
CL2
99.941A
1.003A
1.002A
1.002A
1225.824
87.099%
2061
52.4
43.49°C
0.998
12.132V
5.030V
3.312V
4.965V
1407.386
54.91°C
115.12V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.190A
0.492A
0.479A
0.197A
19.666
65.696%
732
24.3
0.852
12.252V
5.052V
3.329V
5.099V
29.935
115.10V
2
2.408A
0.985A
0.989A
0.391A
39.751
77.143%
732
24.3
0.929
12.250V
5.050V
3.326V
5.089V
51.529
115.10V
3
3.625A
1.478A
1.501A
0.591A
59.868
82.050%
732
24.3
0.954
12.251V
5.049V
3.324V
5.078V
72.965
115.10V
4
4.835A
1.982A
1.983A
0.785A
79.802
85.147%
750
25.1
0.975
12.249V
5.050V
3.324V
5.068V
93.723
115.10V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.2 mV
4.4 mV
6.0 mV
6.8 mV
Pass
20% Load
11.1 mV
4.6 mV
6.6 mV
9.2 mV
Pass
30% Load
10.5 mV
5.0 mV
7.0 mV
9.7 mV
Pass
40% Load
9.4 mV
4.9 mV
7.8 mV
11.5 mV
Pass
50% Load
9.8 mV
4.9 mV
7.9 mV
14.0 mV
Pass
60% Load
10.6 mV
5.7 mV
8.3 mV
16.3 mV
Pass
70% Load
11.8 mV
5.7 mV
9.5 mV
18.7 mV
Pass
80% Load
13.0 mV
8.1 mV
11.2 mV
21.7 mV
Pass
90% Load
14.0 mV
8.3 mV
11.8 mV
24.4 mV
Pass
100% Load
16.1 mV
10.5 mV
13.8 mV
28.5 mV
Pass
110% Load
31.0 mV
17.2 mV
14.3 mV
40.1 mV
Pass
Crossload 1
9.9 mV
5.9 mV
8.2 mV
7.7 mV
Pass
Crossload 2
15.6 mV
7.4 mV
12.7 mV
25.8 mV
Pass
The results above are not used in the certification process