This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.212
65.231%
0.036
5.128V
0.325
115.09V
2
0.087A
0.446
73.115%
0.067
5.126V
0.610
115.09V
3
0.532A
2.716
80.785%
0.271
5.106V
3.362
115.09V
4
3.001A
14.997
79.148%
0.477
4.997V
18.948
115.09V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
6.476A
1.984A
1.990A
0.986A
99.815
89.341%
698
24.1
36.97°C
0.979
12.082V
5.028V
3.316V
5.069V
111.723
40.99°C
115.05V
2
13.984A
2.979A
2.984A
1.186A
199.688
91.758%
698
24.1
37.49°C
0.986
12.073V
5.028V
3.314V
5.052V
217.625
42.29°C
115.04V
3
21.867A
3.486A
3.499A
1.390A
299.928
92.261%
732
24.3
38.07°C
0.986
12.065V
5.025V
3.312V
5.033V
325.086
43.73°C
115.03V
4
29.743A
3.980A
3.983A
1.596A
399.736
92.094%
882
31.7
38.86°C
0.990
12.055V
5.024V
3.311V
5.013V
434.051
44.62°C
115.03V
5
37.290A
4.974A
4.986A
1.802A
499.676
91.492%
1339
42
39.10°C
0.993
12.046V
5.024V
3.308V
4.993V
546.140
45.14°C
115.04V
6
44.848A
5.972A
5.987A
2.010A
599.634
90.512%
1870
50.1
40.32°C
0.995
12.037V
5.025V
3.306V
4.973V
662.492
46.70°C
115.04V
7
52.418A
6.970A
6.992A
2.217A
699.533
89.691%
2043
52.0
40.95°C
0.996
12.027V
5.024V
3.304V
4.954V
779.940
47.50°C
115.05V
8
59.996A
7.965A
7.998A
2.430A
799.447
88.891%
2043
52.0
42.32°C
0.996
12.018V
5.024V
3.302V
4.934V
899.360
49.23°C
115.06V
9
68.019A
8.467A
8.516A
2.435A
899.453
88.082%
2043
52.0
43.81°C
0.997
12.009V
5.023V
3.299V
4.924V
1021.154
51.22°C
115.07V
10
75.797A
8.970A
9.005A
3.070A
999.281
86.961%
2043
52.0
45.16°C
0.997
12.000V
5.020V
3.298V
4.882V
1149.115
53.18°C
115.08V
11
84.190A
8.974A
9.010A
3.076A
1099.153
85.822%
2043
52.0
45.94°C
0.997
11.990V
5.018V
3.296V
4.872V
1280.743
55.79°C
115.09V
CL1
0.099A
15.020A
15.004A
0.004A
126.643
84.306%
1989
51.8
42.67°C
0.988
12.099V
5.045V
3.309V
5.096V
150.218
47.16°C
115.11V
CL2
82.934A
1.003A
1.004A
1.002A
1007.567
87.409%
2043
52.0
43.45°C
0.997
11.988V
5.013V
3.309V
4.995V
1152.704
51.11°C
115.10V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.209A
0.491A
0.482A
0.195A
19.684
74.363%
0
0
0.821
12.087V
5.034V
3.323V
5.115V
26.470
115.04V
2
2.445A
0.989A
0.992A
0.390A
39.812
83.374%
0
0
0.918
12.087V
5.031V
3.321V
5.101V
47.751
115.04V
3
3.678A
1.486A
1.505A
0.586A
59.903
87.087%
0
0
0.953
12.086V
5.029V
3.318V
5.092V
68.785
115.04V
4
4.903A
1.983A
1.989A
0.786A
79.808
88.204%
698
24.1
0.970
12.084V
5.028V
3.317V
5.080V
90.481
115.04V
The results above are not used in the certification process
115V
Test
12V
5V
.3V
5VSB
Pass/Fail
10% Load
10.8 mV
5.1 mV
5.6 mV
7.0 mV
Pass
20% Load
13.7 mV
5.4 mV
5.7 mV
8.1 mV
Pass
30% Load
15.3 mV
5.8 mV
6.6 mV
9.5 mV
Pass
40% Load
13.1 mV
5.6 mV
7.2 mV
11.2 mV
Pass
50% Load
11.3 mV
5.5 mV
8.9 mV
13.4 mV
Pass
60% Load
10.8 mV
6.0 mV
10.2 mV
15.6 mV
Pass
70% Load
12.1 mV
6.7 mV
10.7 mV
17.1 mV
Pass
80% Load
13.5 mV
7.0 mV
11.6 mV
19.7 mV
Pass
90% Load
14.6 mV
7.2 mV
12.8 mV
22.5 mV
Pass
100% Load
15.3 mV
7.5 mV
14.0 mV
22.4 mV
Pass
110% Load
22.9 mV
8.7 mV
14.3 mV
25.0 mV
Pass
Crossload 1
10.3 mV
6.6 mV
6.9 mV
7.1 mV
Pass
Crossload 2
15.4 mV
7.1 mV
13.8 mV
20.7 mV
Pass
The results above are not used in the certification process