This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.215
66.154%
0.037
5.107V
0.325
115.05V
2
0.088A
0.447
73.159%
0.068
5.106V
0.611
115.05V
3
0.533A
2.707
80.136%
0.283
5.085V
3.378
115.06V
4
2.502A
12.500
79.547%
0.481
4.997V
15.714
115.05V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.374A
1.996A
1.983A
0.991A
74.800
86.790%
732
24.3
38.43°C
0.971
12.160V
5.021V
3.324V
5.044V
86.185
41.94°C
115.14V
2
9.783A
2.981A
2.978A
1.191A
149.742
90.182%
732
24.3
39.14°C
0.991
12.153V
5.021V
3.323V
5.025V
166.045
42.80°C
115.12V
3
15.542A
3.489A
3.488A
1.397A
224.860
91.095%
770
27.4
39.25°C
0.986
12.146V
5.020V
3.320V
5.005V
246.841
43.19°C
115.11V
4
21.300A
3.985A
3.975A
1.601A
299.738
91.215%
968
32.5
39.60°C
0.986
12.139V
5.020V
3.319V
4.985V
328.605
43.78°C
115.10V
5
26.727A
4.980A
4.974A
1.812A
374.738
90.864%
1183
40.3
40.35°C
0.989
12.132V
5.019V
3.316V
4.966V
412.417
44.82°C
115.10V
6
32.154A
5.977A
5.973A
2.020A
449.649
90.265%
1577
44.1
40.59°C
0.990
12.125V
5.019V
3.314V
4.945V
498.142
45.35°C
115.09V
7
37.588A
6.981A
6.975A
2.232A
524.661
89.563%
1800
50.8
41.60°C
0.991
12.119V
5.019V
3.312V
4.925V
585.804
46.83°C
115.09V
8
43.031A
7.972A
7.975A
2.447A
599.550
88.690%
2061
52.4
42.95°C
0.991
12.111V
5.019V
3.310V
4.901V
676.003
48.73°C
115.08V
9
48.911A
8.474A
8.495A
2.451A
674.636
88.071%
2061
52.4
43.93°C
0.989
12.104V
5.018V
3.308V
4.893V
766.016
50.24°C
115.06V
10
54.748A
8.975A
8.981A
2.559A
749.452
87.341%
2061
52.4
44.79°C
0.982
12.096V
5.017V
3.307V
4.882V
858.076
51.60°C
115.05V
11
60.967A
8.979A
8.984A
2.560A
824.310
86.326%
2061
52.4
45.34°C
0.968
12.090V
5.016V
3.306V
4.875V
954.876
52.71°C
115.02V
CL1
0.100A
12.012A
12.005A
0.004A
101.537
83.524%
2043
52.0
43.52°C
0.985
12.169V
5.036V
3.316V
5.082V
121.566
47.92°C
115.11V
CL2
61.948A
1.004A
1.003A
1.002A
762.053
87.806%
2061
52.4
43.78°C
0.986
12.086V
5.009V
3.317V
4.984V
867.883
49.87°C
115.06V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.200A
0.494A
0.480A
0.197A
19.681
72.487%
732
24.3
0.825
12.164V
5.026V
3.331V
5.094V
27.151
115.14V
2
2.422A
0.991A
0.991A
0.392A
39.724
81.765%
732
24.3
0.914
12.162V
5.023V
3.329V
5.080V
48.583
115.15V
3
3.653A
1.488A
1.502A
0.591A
59.876
85.492%
732
24.3
0.950
12.160V
5.021V
3.325V
5.068V
70.037
115.15V
4
4.869A
1.996A
1.984A
0.791A
79.817
87.466%
732
24.3
0.973
12.159V
5.021V
3.324V
5.055V
91.255
115.16V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.5 mV
4.1 mV
5.6 mV
7.4 mV
Pass
20% Load
12.0 mV
4.3 mV
6.0 mV
7.9 mV
Pass
30% Load
15.8 mV
4.4 mV
7.2 mV
9.2 mV
Pass
40% Load
17.8 mV
5.1 mV
8.0 mV
11.1 mV
Pass
50% Load
10.9 mV
4.4 mV
8.2 mV
12.7 mV
Pass
60% Load
11.8 mV
4.5 mV
9.0 mV
14.7 mV
Pass
70% Load
12.6 mV
5.0 mV
8.5 mV
18.3 mV
Pass
80% Load
15.1 mV
5.1 mV
9.9 mV
19.9 mV
Pass
90% Load
17.3 mV
5.1 mV
11.0 mV
21.0 mV
Pass
100% Load
19.4 mV
5.8 mV
13.0 mV
26.7 mV
Pass
110% Load
23.6 mV
6.2 mV
13.4 mV
27.2 mV
Pass
Crossload 1
12.6 mV
4.8 mV
8.4 mV
6.9 mV
Pass
Crossload 2
18.9 mV
4.9 mV
11.2 mV
18.8 mV
Pass
The results above are not used in the certification process