This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.215
66.154%
0.037
5.107V
0.325
115.05V
2
0.088A
0.447
73.159%
0.068
5.106V
0.611
115.05V
3
0.533A
2.707
80.136%
0.283
5.085V
3.378
115.06V
4
2.502A
12.500
79.547%
0.481
4.997V
15.714
115.05V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.541A
1.985A
1.979A
0.991A
64.806
85.403%
732
24.3
38.60°C
0.951
12.205V
5.033V
3.332V
5.049V
75.883
41.03°C
115.08V
2
8.109A
2.975A
2.970A
1.191A
129.770
89.518%
732
24.3
38.80°C
0.983
12.198V
5.033V
3.330V
5.031V
144.966
41.68°C
115.08V
3
13.024A
3.478A
3.482A
1.396A
194.870
90.681%
750
25.1
39.65°C
0.988
12.192V
5.031V
3.328V
5.011V
214.897
42.62°C
115.07V
4
17.940A
3.974A
3.968A
1.601A
259.783
91.010%
860
29.4
39.74°C
0.984
12.185V
5.031V
3.326V
4.993V
285.445
43.15°C
115.07V
5
22.520A
4.970A
4.961A
1.806A
324.718
90.784%
1165
39.9
40.06°C
0.985
12.178V
5.030V
3.323V
4.975V
357.681
43.20°C
115.06V
6
27.109A
5.964A
5.957A
2.016A
389.717
90.252%
1560
43.8
40.41°C
0.988
12.171V
5.030V
3.321V
4.956V
431.812
43.43°C
115.06V
7
31.695A
6.959A
6.958A
2.226A
454.619
89.584%
1820
51.4
41.21°C
0.990
12.164V
5.029V
3.319V
4.937V
507.480
44.30°C
115.06V
8
36.297A
7.952A
7.956A
2.439A
519.603
88.853%
1990
51.8
41.98°C
0.991
12.156V
5.030V
3.317V
4.915V
584.788
45.13°C
115.06V
9
41.322A
8.456A
8.472A
2.446A
584.648
88.072%
2060
52.4
43.60°C
0.992
12.149V
5.030V
3.316V
4.906V
663.830
47.24°C
115.07V
10
46.306A
8.955A
8.958A
2.551A
649.453
87.412%
2060
52.4
44.03°C
0.992
12.142V
5.028V
3.315V
4.894V
742.981
47.84°C
115.06V
11
51.692A
8.958A
8.962A
2.555A
714.441
86.677%
2060
52.4
45.08°C
0.991
12.134V
5.026V
3.314V
4.887V
824.259
49.59°C
115.06V
CL1
0.099A
12.012A
12.005A
0.005A
101.740
84.406%
1600
44.5
42.40°C
0.984
12.210V
5.045V
3.324V
5.078V
120.536
44.99°C
115.10V
CL2
53.970A
1.003A
1.003A
1.003A
667.975
87.736%
2060
52.4
43.51°C
0.992
12.129V
5.020V
3.323V
4.989V
761.350
47.37°C
115.07V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.195A
0.491A
0.478A
0.197A
19.660
71.749%
732
24.3
0.826
12.209V
5.036V
3.336V
5.094V
27.401
115.08V
2
2.415A
0.991A
0.990A
0.391A
39.757
81.354%
732
24.3
0.911
12.207V
5.034V
3.334V
5.081V
48.869
115.08V
3
3.640A
1.482A
1.500A
0.591A
59.881
85.241%
732
24.3
0.947
12.205V
5.033V
3.333V
5.071V
70.249
115.09V
4
4.853A
1.985A
1.979A
0.792A
79.812
87.351%
732
24.3
0.973
12.203V
5.033V
3.332V
5.058V
91.369
115.08V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.8 mV
4.9 mV
5.7 mV
6.9 mV
Pass
20% Load
10.8 mV
4.1 mV
6.3 mV
6.9 mV
Pass
30% Load
14.1 mV
4.4 mV
9.1 mV
7.9 mV
Pass
40% Load
16.3 mV
4.6 mV
8.0 mV
9.1 mV
Pass
50% Load
18.3 mV
4.9 mV
9.1 mV
9.5 mV
Pass
60% Load
18.5 mV
5.2 mV
10.0 mV
11.6 mV
Pass
70% Load
18.8 mV
5.3 mV
10.0 mV
11.5 mV
Pass
80% Load
20.3 mV
5.3 mV
10.1 mV
11.6 mV
Pass
90% Load
23.0 mV
6.1 mV
10.4 mV
11.7 mV
Pass
100% Load
26.6 mV
7.2 mV
12.1 mV
15.0 mV
Pass
110% Load
29.2 mV
7.5 mV
12.9 mV
16.1 mV
Pass
Crossload 1
10.0 mV
5.4 mV
6.9 mV
7.0 mV
Pass
Crossload 2
27.0 mV
7.1 mV
11.8 mV
11.8 mV
Pass
The results above are not used in the certification process