Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan )
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
温度范围 (°C /°F)
30-32 / 86-89.6
符合ErP Lot3/6规范
✓
符合(EU) No 617/2013规范
✓
Performance Summary 230V
效率等级
SILVER
噪音等级
Standard+
平均效率 (>1450 load combinations)
87.201%
Average Noise Output (>1450 Load Combinations)
37.06dBA
PF平均值 (>1450 Load Combinations)
0.927
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
待机功率耗损
0.1856W
12V Ripple (Full Load)
40.19mV
5V Ripple (Full Load)
26.26mV
3.3V Ripple (Full Load)
23.71mV
5VSB Ripple (Full Load)
41.38mV
12V Load Regulation
1.71%
5V Load Regulation
3.12%
3.3V Load Regulation
3.66%
5VSB Load Regulation
3.99%
Inrush Current
88.906A
保持时间 & PG信号
22.00ms
AC Loss to PWR_OK Hold Up Time
70.00ms
PWR_OK Inactive to DC Loss Delay
-48.00ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
120.15%
0.00%
保持时间 & PG信号
Hold-Up Time (ms)
22
AC Loss to PWR_OK Hold Up Time (ms)
70
PWR_OK Inactive to DC Loss Delay (ms)
-48
待机电源
Tables 230V
Graphs 230V
资讯
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
转换效率图表
230V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
噪音值图表
230V
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 230V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.233
46.600%
0.009
5.171V
0.500
230.28V
2
0.090A
0.466
59.363%
0.014
5.170V
0.785
230.26V
3
0.550A
2.837
77.051%
0.066
5.156V
3.682
230.26V
4
1.000A
5.143
78.856%
0.114
5.143V
6.522
230.27V
5
1.500A
7.692
79.537%
0.161
5.128V
9.671
230.27V
6
3.000A
15.246
79.064%
0.267
5.082V
19.283
230.28V
Protection Features
Supplementary Tests (For Reference)
10-110%负载测试 230V
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
1
4.370A
2.006A
1.965A
0.975A
74.490
77.205%
1077
23.2
34.51°C
0.679
12.102V
4.988V
3.358V
5.129V
96.484
40.29°C
230.29V
2
9.807A
3.019A
2.959A
1.174A
149.381
87.438%
1169
25.7
35.26°C
0.839
12.081V
4.970V
3.345V
5.112V
170.842
41.37°C
230.29V
3
15.674A
3.531A
3.447A
1.374A
224.900
89.912%
1157
25.4
35.99°C
0.915
12.052V
4.957V
3.334V
5.095V
250.134
42.50°C
230.29V
4
21.493A
4.047A
3.973A
1.576A
299.680
90.055%
1340
30.2
36.56°C
0.941
12.026V
4.943V
3.322V
5.077V
332.773
43.44°C
230.29V
5
26.993A
5.077A
4.988A
1.779A
374.592
89.717%
1772
38.2
36.95°C
0.949
12.006V
4.926V
3.309V
5.059V
417.526
44.56°C
230.29V
6
32.518A
6.112A
6.009A
1.985A
449.497
89.183%
1893
38.4
37.21°C
0.967
11.984V
4.908V
3.295V
5.040V
504.017
45.49°C
230.29V
7
38.097A
7.161A
7.040A
2.192A
524.831
88.483%
2106
41.5
37.90°C
0.975
11.962V
4.889V
3.281V
5.021V
593.144
46.64°C
230.29V
8
43.692A
8.214A
8.080A
2.400A
600.133
87.682%
2358
44.3
38.28°C
0.978
11.941V
4.871V
3.267V
5.000V
684.443
47.49°C
230.29V
9
49.678A
8.753A
8.602A
2.407A
674.680
86.829%
2406
45.1
39.09°C
0.980
11.920V
4.857V
3.255V
4.988V
777.024
48.59°C
230.28V
10
55.487A
9.296A
9.159A
3.028A
749.892
85.725%
2407
45.1
39.44°C
0.978
11.898V
4.842V
3.242V
4.955V
874.762
49.81°C
230.29V
11
61.923A
9.316A
9.191A
3.036A
825.123
84.431%
2400
45.1
39.88°C
0.976
11.876V
4.832V
3.232V
4.942V
977.277
51.11°C
230.29V
CL1
0.146A
14.004A
13.999A
0.000A
116.578
77.537%
1944
40.1
36.61°C
0.787
12.074V
4.887V
3.313V
5.126V
150.352
44.45°C
230.29V
CL2
62.011A
1.002A
1.000A
1.000A
751.724
86.546%
2414
45.3
39.35°C
0.979
11.909V
4.914V
3.275V
5.036V
868.585
49.36°C
230.29V
The results above are not used in the certification process
20-80瓦负载测试 230V
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
PF/AC 电压
1
1.196A
0.499A
0.475A
0.194A
19.533
78.626%
0
<6.0
0.335
12.065V
5.010V
3.373V
5.163V
24.843
230.26V
2
2.458A
0.998A
0.980A
0.388A
39.961
84.525%
0
<6.0
0.531
12.070V
5.003V
3.368V
5.154V
47.277
230.27V
3
3.639A
1.502A
1.457A
0.583A
59.451
74.373%
928
19.4
0.645
12.105V
4.994V
3.363V
5.144V
79.936
230.28V
4
4.899A
2.006A
1.963A
0.779A
79.874
78.735%
1065
23.0
0.699
12.100V
4.987V
3.358V
5.134V
101.446
230.28V
The results above are not used in the certification process
纹波测量 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
11.5 mV
15.9 mV
10.6 mV
20.7 mV
Pass
20% Load
13.0 mV
16.5 mV
12.6 mV
22.5 mV
Pass
30% Load
33.5 mV
16.6 mV
13.9 mV
25.6 mV
Pass
40% Load
30.7 mV
17.9 mV
14.7 mV
26.9 mV
Pass
50% Load
28.8 mV
19.5 mV
15.4 mV
29.1 mV
Pass
60% Load
27.8 mV
19.3 mV
16.7 mV
30.6 mV
Pass
70% Load
25.8 mV
20.0 mV
19.3 mV
32.7 mV
Pass
80% Load
34.2 mV
22.4 mV
20.9 mV
33.5 mV
Pass
90% Load
27.4 mV
24.3 mV
21.6 mV
33.7 mV
Pass
100% Load
40.2 mV
26.3 mV
23.7 mV
41.4 mV
Pass
110% Load
42.0 mV
28.2 mV
24.7 mV
44.2 mV
Pass
Crossload 1
18.1 mV
26.9 mV
22.1 mV
22.9 mV
Pass
Crossload 2
38.8 mV
24.0 mV
18.0 mV
40.5 mV
Pass
The results above are not used in the certification process