Thermal Control DF1202512SELN (120mm, 12V, 0.25A, Rifle Bearing Fan)
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
温度范围 (°C /°F)
30-32 / 86-89.6
符合ErP Lot3/6规范
✓
符合(EU) No 617/2013规范
✓
Performance Summary 230V
效率等级
BRONZE
噪音等级
Standard++
平均效率 (>1450 load combinations)
86.182%
Average Noise Output (>1450 Load Combinations)
32.25dBA
PF平均值 (>1450 Load Combinations)
0.913
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
待机功率耗损
0.1818W
12V Ripple (Full Load)
51.42mV
5V Ripple (Full Load)
24.00mV
3.3V Ripple (Full Load)
27.41mV
5VSB Ripple (Full Load)
20.93mV
12V Load Regulation
1.11%
5V Load Regulation
2.27%
3.3V Load Regulation
2.31%
5VSB Load Regulation
3.31%
Inrush Current
67.026A
保持时间 & PG信号
11.00ms
AC Loss to PWR_OK Hold Up Time
13.20ms
PWR_OK Inactive to DC Loss Delay
-2.20ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
保持时间 & PG信号
Hold-Up Time (ms)
11
AC Loss to PWR_OK Hold Up Time (ms)
13.2
PWR_OK Inactive to DC Loss Delay (ms)
-2.2
待机电源
Tables 230V
Graphs 230V
资讯
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
转换效率图表
230V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
噪音值图表
230V
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN55032 & CISPR 32A
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 230V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.233
47.071%
0.010
5.183V
0.495
230.29V
2
0.090A
0.467
59.490%
0.015
5.181V
0.785
230.29V
3
0.550A
2.843
76.796%
0.070
5.168V
3.702
230.29V
4
1.000A
5.155
78.594%
0.118
5.154V
6.559
230.29V
5
1.500A
7.710
79.248%
0.165
5.139V
9.729
230.29V
6
3.000A
15.279
78.644%
0.266
5.093V
19.428
230.28V
Supplementary Tests (For Reference)
10-110%负载测试 230V
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
1
1.911A
2.004A
1.954A
0.973A
44.801
83.441%
0
<6.0
42.23°C
0.617
12.146V
4.985V
3.376V
5.142V
53.692
35.25°C
230.28V
2
4.800A
3.019A
2.942A
1.170A
89.290
85.287%
1114
24.6
35.91°C
0.811
12.165V
4.969V
3.364V
5.128V
104.693
43.53°C
230.28V
3
8.109A
3.529A
3.427A
1.369A
134.419
87.196%
1257
28.8
36.46°C
0.883
12.137V
4.958V
3.356V
5.115V
154.158
44.34°C
230.29V
4
11.422A
4.043A
3.943A
1.569A
179.663
87.747%
1401
31.9
36.88°C
0.919
12.122V
4.947V
3.348V
5.101V
204.750
45.15°C
230.30V
5
14.412A
5.067A
4.942A
1.770A
224.975
87.618%
1539
33.8
37.27°C
0.939
12.106V
4.934V
3.339V
5.086V
256.768
46.23°C
230.31V
6
17.342A
6.096A
5.946A
1.973A
269.503
87.372%
1535
33.8
37.75°C
0.951
12.092V
4.921V
3.330V
5.071V
308.455
47.58°C
230.32V
7
20.346A
7.133A
6.954A
2.177A
314.827
86.835%
1534
33.8
38.10°C
0.959
12.077V
4.908V
3.321V
5.055V
362.559
48.49°C
230.32V
8
23.362A
8.175A
7.969A
2.382A
360.159
86.107%
1536
33.8
38.75°C
0.965
12.060V
4.894V
3.313V
5.039V
418.271
49.63°C
230.33V
9
26.778A
8.701A
8.469A
2.387A
405.074
85.233%
1533
33.7
39.38°C
0.969
12.046V
4.885V
3.306V
5.029V
475.257
50.86°C
230.33V
10
29.940A
9.234A
9.006A
3.000A
449.891
84.100%
1530
33.7
39.74°C
0.973
12.030V
4.874V
3.298V
5.001V
534.947
51.56°C
230.37V
11
33.703A
9.245A
9.021A
3.005A
494.684
83.302%
1533
33.7
40.27°C
0.976
12.016V
4.868V
3.292V
4.994V
593.844
52.63°C
230.34V
CL1
0.143A
12.001A
12.001A
0.000A
100.697
81.507%
1529
33.7
37.12°C
0.847
12.144V
4.909V
3.337V
5.137V
123.544
46.04°C
230.40V
CL2
37.017A
1.003A
0.999A
1.000A
458.816
84.806%
1535
33.8
39.56°C
0.973
12.034V
4.932V
3.325V
5.085V
541.019
51.37°C
230.34V
The results above are not used in the certification process
20-80瓦负载测试 230V
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
PF/AC 电压
1
1.188A
0.500A
0.472A
0.193A
19.508
78.671%
0
<6.0
0.368
12.131V
5.000V
3.384V
5.173V
24.797
230.30V
2
2.441A
1.002A
0.974A
0.387A
39.941
83.716%
0
<6.0
0.577
12.146V
4.993V
3.379V
5.163V
47.710
230.33V
3
3.625A
1.504A
1.450A
0.582A
59.396
85.537%
0
<6.0
0.698
12.139V
4.987V
3.375V
5.153V
69.439
230.34V
4
4.884A
2.008A
1.956A
0.778A
79.812
86.516%
0
<6.0
0.778
12.125V
4.980V
3.371V
5.143V
92.251
230.28V
The results above are not used in the certification process
纹波测量 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
65.9 mV
23.0 mV
15.6 mV
14.0 mV
Pass
20% Load
53.0 mV
20.3 mV
17.3 mV
13.2 mV
Pass
30% Load
46.3 mV
21.0 mV
17.1 mV
13.1 mV
Pass
40% Load
45.1 mV
20.9 mV
17.2 mV
13.2 mV
Pass
50% Load
44.1 mV
20.9 mV
18.9 mV
13.9 mV
Pass
60% Load
48.8 mV
21.3 mV
20.4 mV
14.9 mV
Pass
70% Load
45.8 mV
23.8 mV
21.4 mV
14.9 mV
Pass
80% Load
42.5 mV
22.1 mV
25.0 mV
16.7 mV
Pass
90% Load
42.4 mV
22.0 mV
25.2 mV
17.2 mV
Pass
100% Load
51.4 mV
24.0 mV
27.4 mV
20.9 mV
Pass
110% Load
52.9 mV
24.7 mV
28.4 mV
21.3 mV
Pass
Crossload 1
52.1 mV
22.7 mV
30.8 mV
14.4 mV
Pass
Crossload 2
49.1 mV
21.7 mV
18.1 mV
17.0 mV
Pass
The results above are not used in the certification process