This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
74.194%
0.021
5.095V
0.310
115.10V
2
0.090A
0.459
78.866%
0.039
5.093V
0.582
115.08V
3
0.550A
2.792
82.996%
0.195
5.075V
3.364
115.08V
4
1.000A
5.057
82.888%
0.298
5.057V
6.101
115.09V
5
1.500A
7.557
82.266%
0.369
5.037V
9.186
115.10V
6
3.000A
14.939
78.784%
0.469
4.980V
18.962
115.10V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
63.187%
0.007
5.095V
0.364
230.24V
2
0.090A
0.459
72.170%
0.013
5.093V
0.636
230.24V
3
0.550A
2.791
81.134%
0.066
5.074V
3.440
230.24V
4
1.000A
5.057
81.921%
0.114
5.057V
6.173
230.24V
5
1.500A
7.556
82.291%
0.162
5.037V
9.182
230.25V
6
3.000A
14.938
80.533%
0.273
4.979V
18.549
230.25V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
8.908A
2.007A
1.970A
0.990A
129.708
87.479%
648
15.1
39.78°C
0.966
12.135V
4.987V
3.351V
5.050V
148.274
43.72°C
115.13V
2
18.887A
3.011A
2.957A
1.192A
259.813
90.858%
648
15.1
40.97°C
0.958
12.120V
4.983V
3.347V
5.035V
285.956
45.19°C
115.13V
3
29.223A
3.515A
3.438A
1.395A
389.719
91.724%
647
15.1
41.31°C
0.972
12.104V
4.980V
3.344V
5.020V
424.884
47.31°C
115.12V
4
39.586A
4.020A
3.950A
1.599A
519.726
91.808%
649
15.1
41.72°C
0.979
12.088V
4.978V
3.341V
5.005V
566.104
49.52°C
115.12V
5
49.649A
5.028A
4.943A
1.804A
649.871
91.466%
647
15.1
42.32°C
0.984
12.072V
4.974V
3.338V
4.989V
710.507
51.06°C
115.12V
6
59.663A
6.036A
5.937A
2.011A
779.998
90.468%
882
24.1
43.06°C
0.987
12.071V
4.971V
3.335V
4.973V
862.177
52.88°C
115.11V
7
69.760A
7.048A
6.934A
2.220A
910.080
89.777%
1201
32.4
43.84°C
0.989
12.055V
4.968V
3.332V
4.957V
1013.709
54.29°C
115.11V
8
79.903A
8.060A
7.932A
2.430A
1040.203
88.947%
1633
39.7
44.17°C
0.990
12.037V
4.964V
3.328V
4.940V
1169.466
55.30°C
115.11V
9
90.483A
8.569A
8.423A
2.434A
1169.950
88.083%
2187
47.2
45.44°C
0.992
12.018V
4.961V
3.325V
4.933V
1328.240
57.30°C
115.10V
10
100.852A
9.079A
8.942A
3.063A
1299.948
87.135%
2186
47.2
45.86°C
0.992
12.000V
4.958V
3.322V
4.899V
1491.877
58.39°C
115.10V
11
111.817A
9.082A
8.948A
3.066A
1429.727
86.322%
2188
47.2
46.97°C
0.993
11.984V
4.956V
3.319V
4.893V
1656.272
59.90°C
115.09V
CL1
0.139A
16.004A
15.999A
0.000A
134.695
82.860%
647
15.1
42.33°C
0.966
12.134V
4.969V
3.343V
5.081V
162.557
51.05°C
115.12V
CL2
107.994A
1.002A
1.002A
1.000A
1309.775
87.479%
2185
47.2
45.52°C
0.993
12.005V
4.971V
3.328V
4.992V
1497.248
57.87°C
115.09V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
8.901A
2.006A
1.966A
0.990A
129.605
86.077%
648
15.1
39.83°C
0.811
12.135V
4.986V
3.351V
5.051V
150.569
43.67°C
230.24V
2
18.866A
3.009A
2.956A
1.192A
259.715
91.334%
647
15.1
40.61°C
0.896
12.129V
4.982V
3.348V
5.035V
284.357
45.15°C
230.24V
3
29.189A
3.515A
3.437A
1.395A
389.622
92.269%
648
15.1
41.10°C
0.923
12.115V
4.979V
3.344V
5.020V
422.268
46.25°C
230.23V
4
39.539A
4.020A
3.950A
1.599A
519.705
92.941%
647
15.1
41.83°C
0.938
12.102V
4.976V
3.341V
5.005V
559.176
48.37°C
230.23V
5
49.582A
5.028A
4.943A
1.804A
649.851
93.089%
649
15.1
42.30°C
0.948
12.088V
4.973V
3.338V
4.989V
698.099
49.51°C
230.24V
6
59.668A
6.039A
5.936A
2.012A
780.003
92.808%
913
25.1
42.81°C
0.955
12.070V
4.969V
3.335V
4.973V
840.450
51.19°C
230.25V
7
69.768A
7.050A
6.934A
2.220A
910.094
92.420%
1220
32.7
43.15°C
0.959
12.054V
4.966V
3.331V
4.956V
984.739
52.19°C
230.27V
8
79.910A
8.063A
7.934A
2.430A
1040.207
91.947%
1625
39.6
43.97°C
0.963
12.036V
4.962V
3.327V
4.940V
1131.314
53.83°C
230.27V
9
90.495A
8.573A
8.422A
2.434A
1169.993
91.439%
2154
47.0
44.49°C
0.967
12.017V
4.959V
3.324V
4.933V
1279.527
55.27°C
230.28V
10
100.875A
9.083A
8.945A
3.063A
1300.026
90.919%
2186
47.2
45.65°C
0.970
11.998V
4.956V
3.321V
4.899V
1429.880
56.85°C
230.28V
11
111.867A
9.085A
8.950A
3.067A
1429.983
90.509%
2190
47.2
46.73°C
0.973
11.981V
4.954V
3.318V
4.891V
1579.931
58.67°C
230.28V
CL1
0.151A
16.004A
15.999A
0.000A
134.825
81.474%
647
15.1
42.33°C
0.825
12.134V
4.968V
3.343V
5.080V
165.483
49.53°C
230.28V
CL2
108.016A
1.003A
1.003A
1.000A
1309.613
91.220%
2186
47.2
45.42°C
0.971
12.001V
4.970V
3.328V
4.990V
1435.657
56.73°C
230.28V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.195A
0.503A
0.478A
0.197A
19.630
60.965%
648
15.1
0.759
12.147V
4.990V
3.352V
5.088V
32.199
115.15V
2
2.450A
1.004A
0.985A
0.394A
40.068
74.588%
648
15.1
0.876
12.145V
4.990V
3.352V
5.079V
53.719
115.15V
3
3.632A
1.504A
1.463A
0.592A
59.512
80.219%
648
15.1
0.914
12.143V
4.989V
3.352V
5.070V
74.187
115.15V
4
4.889A
2.007A
1.967A
0.790A
79.960
83.239%
648
15.1
0.939
12.141V
4.988V
3.352V
5.061V
96.061
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.184A
0.501A
0.478A
0.197A
19.494
45.976%
648
15.1
0.480
12.153V
4.988V
3.353V
5.090V
42.400
230.24V
2
2.441A
1.002A
0.984A
0.394A
39.941
68.546%
648
15.1
0.566
12.144V
4.988V
3.352V
5.080V
58.269
230.24V
3
3.623A
1.504A
1.458A
0.592A
59.381
76.085%
648
15.1
0.643
12.142V
4.988V
3.352V
5.071V
78.046
230.23V
4
4.881A
2.005A
1.969A
0.790A
79.847
80.324%
648
15.1
0.706
12.139V
4.987V
3.352V
5.061V
99.406
230.23V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.3 mV
13.7 mV
13.2 mV
13.7 mV
Pass
20% Load
11.3 mV
14.9 mV
13.3 mV
12.6 mV
Pass
30% Load
13.5 mV
14.9 mV
14.8 mV
14.5 mV
Pass
40% Load
15.2 mV
15.2 mV
14.3 mV
15.8 mV
Pass
50% Load
18.0 mV
16.4 mV
15.8 mV
16.2 mV
Pass
60% Load
17.8 mV
16.8 mV
20.2 mV
17.3 mV
Pass
70% Load
19.4 mV
19.2 mV
21.2 mV
16.7 mV
Pass
80% Load
22.1 mV
18.5 mV
19.4 mV
18.5 mV
Pass
90% Load
24.8 mV
19.2 mV
20.3 mV
20.6 mV
Pass
100% Load
28.0 mV
22.4 mV
23.6 mV
24.2 mV
Pass
110% Load
30.9 mV
23.8 mV
24.4 mV
28.4 mV
Pass
Crossload 1
12.5 mV
19.4 mV
19.6 mV
13.4 mV
Pass
Crossload 2
27.5 mV
17.4 mV
19.6 mV
23.6 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.2 mV
14.0 mV
12.6 mV
13.6 mV
Pass
20% Load
11.2 mV
14.8 mV
14.0 mV
12.6 mV
Pass
30% Load
16.1 mV
14.9 mV
14.5 mV
14.1 mV
Pass
40% Load
12.0 mV
15.5 mV
14.6 mV
13.2 mV
Pass
50% Load
14.3 mV
16.0 mV
15.9 mV
15.3 mV
Pass
60% Load
16.5 mV
15.9 mV
20.3 mV
14.2 mV
Pass
70% Load
18.1 mV
17.0 mV
19.6 mV
15.5 mV
Pass
80% Load
20.1 mV
17.5 mV
17.4 mV
16.3 mV
Pass
90% Load
22.4 mV
17.4 mV
17.0 mV
17.0 mV
Pass
100% Load
26.0 mV
20.7 mV
18.0 mV
19.4 mV
Pass
110% Load
27.9 mV
18.9 mV
18.6 mV
20.6 mV
Pass
Crossload 1
13.5 mV
18.6 mV
19.8 mV
11.3 mV
Pass
Crossload 2
25.9 mV
14.6 mV
14.7 mV
17.2 mV
Pass
The results above are not used in the certification process