ErP Lot 6 2010: ✓
ErP Lot 6 2013: Partially
ErP Lot 3 2014: ✓
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
Efficiency Rating
PLATINUM
Noise Rating
Standard++
Average Efficiency (>1450 load combinations)
89.416%
Average Noise Output (>1450 Load Combinations)
33.81dBA
Average PF (>1450 Load Combinations)
0.986
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1446W
12V Ripple (Full Load)
12.48mV
5V Ripple (Full Load)
5.99mV
3.3V Ripple (Full Load)
7.59mV
5VSB Ripple (Full Load)
11.83mV
12V Load Regulation
0.36%
5V Load Regulation
0.16%
3.3V Load Regulation
0.24%
5VSB Load Regulation
1.84%
Inrush Current
43.217A
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
16.9
AC Loss to PWR_OK Hold Up Time (ms)
16.1
PWR_OK Inactive to DC Loss Delay (ms)
0.8
Vampire Power
Tables 115V
Graphs 115V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.214
52.195%
0.030
5.102V
0.410
114.98V
2
0.087A
0.444
64.348%
0.051
5.101V
0.690
114.98V
3
0.532A
2.708
76.003%
0.222
5.090V
3.563
114.97V
4
3.002A
15.085
76.302%
0.478
5.025V
19.770
114.97V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.234A
2.004A
1.990A
0.984A
84.791
85.408%
1592
37.2
38.51°C
0.953
12.074V
4.991V
3.316V
5.075V
99.278
40.37°C
115.08V
2
11.503A
3.000A
2.986A
1.179A
169.639
89.250%
1653
38.1
39.86°C
0.976
12.066V
4.990V
3.315V
5.068V
190.072
42.21°C
115.07V
3
18.144A
3.508A
3.498A
1.380A
254.875
90.525%
1688
38.7
40.53°C
0.985
12.059V
4.989V
3.314V
5.060V
281.553
43.47°C
115.12V
4
24.774A
4.009A
3.980A
1.581A
339.724
90.885%
1750
39.3
41.19°C
0.990
12.051V
4.988V
3.313V
5.054V
373.794
44.67°C
115.22V
5
31.062A
5.009A
4.977A
1.780A
424.622
90.807%
1790
40.4
42.06°C
0.992
12.046V
4.988V
3.312V
5.045V
467.607
46.14°C
115.24V
6
37.354A
6.015A
5.976A
1.981A
509.630
90.372%
1835
41.7
42.51°C
0.994
12.043V
4.988V
3.312V
5.038V
563.924
47.30°C
115.09V
7
43.638A
7.016A
6.975A
2.185A
594.558
89.913%
1890
42.6
43.39°C
0.995
12.042V
4.986V
3.311V
5.031V
661.260
48.68°C
115.12V
8
49.934A
8.024A
7.975A
2.386A
679.546
89.242%
1910
42.8
43.77°C
0.996
12.039V
4.986V
3.310V
5.023V
761.462
50.00°C
115.09V
9
56.665A
8.523A
8.491A
2.390A
764.610
88.777%
1981
44.0
44.67°C
0.996
12.036V
4.985V
3.310V
5.020V
861.275
51.64°C
115.11V
10
63.133A
9.035A
8.976A
2.997A
849.382
88.024%
2045
44.7
45.55°C
0.996
12.033V
4.983V
3.308V
5.001V
964.944
53.48°C
115.18V
11
70.211A
9.042A
8.983A
3.000A
934.374
87.293%
2124
45.5
46.67°C
0.996
12.030V
4.981V
3.307V
4.997V
1070.390
55.29°C
115.09V
CL1
0.099A
14.024A
14.005A
0.003A
118.149
82.328%
1981
44.0
44.16°C
0.974
12.064V
5.012V
3.331V
5.092V
143.510
48.03°C
115.09V
CL2
70.794A
1.002A
1.003A
1.001A
864.929
88.437%
2019
44.6
46.23°C
0.996
12.029V
4.968V
3.299V
5.055V
978.020
53.70°C
115.11V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.210A
0.501A
0.478A
0.197A
19.687
74.106%
0
<6.0
0.743
12.065V
4.989V
3.315V
5.095V
26.566
115.07V
2
2.445A
1.000A
0.996A
0.390A
39.788
78.830%
1615
37.5
0.875
12.070V
4.989V
3.315V
5.092V
50.473
115.07V
3
3.678A
1.496A
1.507A
0.586A
59.863
83.104%
1542
37.5
0.924
12.077V
4.991V
3.316V
5.086V
72.034
115.07V
4
4.901A
2.004A
1.990A
0.786A
79.768
85.165%
1565
36.8
0.947
12.074V
4.991V
3.316V
5.080V
93.663
115.08V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.6 mV
3.0 mV
4.2 mV
8.0 mV
Pass
20% Load
7.4 mV
3.5 mV
4.3 mV
7.7 mV
Pass
30% Load
8.6 mV
3.5 mV
4.4 mV
10.6 mV
Pass
40% Load
8.5 mV
4.6 mV
4.7 mV
10.8 mV
Pass
50% Load
9.0 mV
3.8 mV
5.1 mV
10.6 mV
Pass
60% Load
9.2 mV
4.3 mV
5.4 mV
10.7 mV
Pass
70% Load
9.7 mV
4.4 mV
6.1 mV
12.0 mV
Pass
80% Load
10.3 mV
4.5 mV
6.6 mV
10.2 mV
Pass
90% Load
10.6 mV
4.8 mV
7.1 mV
11.7 mV
Pass
100% Load
12.5 mV
6.0 mV
7.6 mV
11.8 mV
Pass
110% Load
13.0 mV
6.1 mV
8.2 mV
14.4 mV
Pass
Crossload 1
7.4 mV
4.3 mV
4.5 mV
20.5 mV
Pass
Crossload 2
11.2 mV
5.6 mV
7.3 mV
11.9 mV
Pass
The results above are not used in the certification process
EVGA SuperNOVA 850 G3
Top side
Labels on the unit`s bottom side
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted