This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228
73.548%
0.051
5.086V
0.310
115.04V
2
0.090A
0.457
76.936%
0.095
5.085V
0.594
115.05V
3
0.550A
2.793
80.259%
0.319
5.078V
3.480
115.04V
4
1.000A
5.071
81.032%
0.382
5.071V
6.258
115.04V
5
1.500A
7.595
79.446%
0.419
5.063V
9.560
115.04V
6
3.000A
15.122
78.491%
0.466
5.041V
19.266
115.04V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.229
66.570%
0.017
5.086V
0.344
230.18V
2
0.090A
0.457
72.540%
0.031
5.085V
0.630
230.18V
3
0.550A
2.793
78.301%
0.155
5.078V
3.567
230.16V
4
1.000A
5.071
80.149%
0.230
5.071V
6.327
230.16V
5
1.500A
7.596
80.169%
0.284
5.063V
9.475
230.16V
6
3.000A
15.120
79.633%
0.359
5.040V
18.987
230.17V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.522A
1.982A
2.001A
0.988A
39.988
80.699%
654
10.7
34.68°C
0.950
12.088V
5.046V
3.293V
5.061V
49.552
41.32°C
115.11V
2
4.038A
2.975A
3.006A
1.188A
79.668
85.086%
655
10.7
34.82°C
0.970
12.078V
5.043V
3.291V
5.052V
93.632
42.08°C
115.10V
3
6.896A
3.473A
3.496A
1.388A
119.198
86.352%
648
10.5
35.16°C
0.976
12.064V
5.041V
3.288V
5.045V
138.037
43.58°C
115.10V
4
9.820A
3.971A
4.014A
1.589A
159.608
86.732%
653
10.7
35.38°C
0.982
12.058V
5.037V
3.287V
5.036V
184.024
45.44°C
115.10V
5
12.384A
4.967A
5.023A
1.791A
199.723
86.480%
659
10.7
35.74°C
0.986
12.050V
5.033V
3.284V
5.026V
230.946
47.54°C
115.10V
6
14.952A
5.962A
6.030A
1.994A
239.845
85.928%
663
10.8
36.15°C
0.988
12.042V
5.031V
3.283V
5.016V
279.122
49.90°C
115.10V
7
17.489A
6.963A
7.040A
2.198A
279.554
85.080%
881
17.8
36.73°C
0.990
12.033V
5.028V
3.281V
5.005V
328.577
51.20°C
115.10V
8
20.098A
7.961A
8.051A
2.403A
320.045
84.240%
1165
26.8
37.15°C
0.991
12.023V
5.025V
3.279V
4.995V
379.919
52.42°C
115.10V
9
23.047A
8.465A
8.546A
2.406A
359.375
83.478%
1472
33.4
37.58°C
0.992
12.013V
5.022V
3.276V
4.989V
430.505
53.89°C
115.10V
10
25.837A
8.968A
9.071A
3.016A
399.781
82.511%
1829
39.3
38.04°C
0.993
12.001V
5.019V
3.274V
4.974V
484.520
55.34°C
115.18V
11
30.033A
8.972A
9.075A
3.020A
449.797
81.473%
1831
39.3
39.55°C
0.994
11.990V
5.016V
3.272V
4.968V
552.084
57.55°C
115.09V
CL1
0.137A
12.000A
12.000A
0.000A
101.362
81.335%
675
11.3
35.78°C
0.977
12.074V
5.028V
3.281V
5.048V
124.623
48.00°C
115.12V
CL2
32.007A
1.001A
0.998A
1.000A
397.670
83.781%
1828
39.3
38.12°C
0.993
12.008V
5.027V
3.282V
5.022V
474.655
55.83°C
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.518A
1.981A
2.002A
0.988A
39.937
82.158%
652
10.6
34.48°C
0.827
12.087V
5.046V
3.293V
5.061V
48.610
40.45°C
230.27V
2
4.035A
2.974A
3.007A
1.188A
79.626
86.815%
654
10.7
34.63°C
0.913
12.077V
5.043V
3.291V
5.052V
91.719
41.53°C
230.27V
3
6.893A
3.469A
3.495A
1.388A
119.161
88.267%
655
10.7
35.20°C
0.942
12.068V
5.040V
3.288V
5.044V
135.001
42.55°C
230.27V
4
9.815A
3.972A
4.015A
1.589A
159.564
88.681%
655
10.7
35.37°C
0.957
12.059V
5.037V
3.287V
5.035V
179.930
44.81°C
230.27V
5
12.381A
4.967A
5.021A
1.791A
199.680
88.603%
657
10.7
35.57°C
0.967
12.050V
5.033V
3.284V
5.026V
225.366
46.22°C
230.27V
6
14.948A
5.964A
6.031A
1.994A
239.795
88.265%
661
10.8
35.88°C
0.971
12.041V
5.031V
3.283V
5.016V
271.676
48.61°C
230.27V
7
17.485A
6.963A
7.038A
2.198A
279.500
87.656%
836
16.5
36.94°C
0.975
12.033V
5.028V
3.281V
5.005V
318.859
50.16°C
230.27V
8
20.095A
7.963A
8.051A
2.403A
320.002
87.032%
1164
26.8
37.07°C
0.979
12.023V
5.024V
3.278V
4.995V
367.682
52.22°C
230.28V
9
23.043A
8.465A
8.547A
2.406A
359.322
86.533%
1463
33.2
37.57°C
0.982
12.013V
5.021V
3.276V
4.989V
415.245
53.93°C
230.27V
10
25.829A
8.967A
9.070A
3.016A
399.729
85.826%
1829
39.3
38.76°C
0.983
12.003V
5.019V
3.274V
4.974V
465.746
55.29°C
230.28V
11
30.025A
8.972A
9.075A
3.020A
449.731
85.226%
1831
39.3
39.62°C
0.985
11.991V
5.016V
3.272V
4.968V
527.695
57.38°C
230.28V
CL1
0.133A
11.999A
11.999A
0.000A
101.293
83.056%
675
11.3
35.53°C
0.936
12.073V
5.027V
3.281V
5.048V
121.957
46.38°C
230.28V
CL2
32.000A
1.003A
0.999A
1.000A
397.597
87.149%
1694
37.3
38.75°C
0.983
12.008V
5.026V
3.282V
5.022V
456.227
55.90°C
230.27V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.199A
0.496A
0.482A
0.197A
19.591
73.803%
645
10.5
0.922
12.091V
5.051V
3.296V
5.080V
26.545
115.12V
2
2.457A
0.991A
0.998A
0.394A
39.986
81.835%
648
10.5
0.948
12.086V
5.048V
3.295V
5.073V
48.862
115.11V
3
3.645A
1.487A
1.486A
0.592A
59.434
84.426%
650
10.6
0.967
12.082V
5.046V
3.293V
5.067V
70.398
115.11V
4
4.906A
1.982A
2.002A
0.790A
79.837
85.752%
652
10.6
0.970
12.077V
5.045V
3.292V
5.061V
93.102
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.192A
0.493A
0.483A
0.197A
19.496
74.783%
648
10.5
0.687
12.092V
5.050V
3.296V
5.079V
26.070
230.27V
2
2.450A
0.991A
1.000A
0.394A
39.910
83.361%
649
10.6
0.825
12.087V
5.048V
3.295V
5.073V
47.876
230.27V
3
3.641A
1.486A
1.484A
0.592A
59.375
86.016%
650
10.6
0.881
12.082V
5.046V
3.293V
5.067V
69.028
230.27V
4
4.902A
1.982A
2.002A
0.790A
79.788
87.519%
652
10.6
0.912
12.077V
5.044V
3.292V
5.061V
91.167
230.27V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.2 mV
6.7 mV
10.6 mV
7.7 mV
Pass
20% Load
8.6 mV
7.1 mV
10.1 mV
8.7 mV
Pass
30% Load
10.2 mV
7.6 mV
11.5 mV
8.5 mV
Pass
40% Load
10.3 mV
7.9 mV
11.6 mV
9.0 mV
Pass
50% Load
11.8 mV
7.8 mV
11.8 mV
15.3 mV
Pass
60% Load
19.7 mV
7.8 mV
13.3 mV
11.4 mV
Pass
70% Load
15.5 mV
9.4 mV
14.4 mV
12.3 mV
Pass
80% Load
16.9 mV
9.5 mV
15.4 mV
16.4 mV
Pass
90% Load
19.4 mV
10.2 mV
16.2 mV
17.3 mV
Pass
100% Load
33.2 mV
10.4 mV
17.6 mV
15.1 mV
Pass
110% Load
39.7 mV
10.5 mV
17.8 mV
15.4 mV
Pass
Crossload 1
12.4 mV
7.9 mV
18.6 mV
8.3 mV
Pass
Crossload 2
30.7 mV
10.5 mV
11.7 mV
10.6 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
4.8 mV
5.0 mV
8.3 mV
5.9 mV
Pass
20% Load
5.4 mV
5.7 mV
8.7 mV
6.5 mV
Pass
30% Load
5.9 mV
5.2 mV
8.5 mV
6.0 mV
Pass
40% Load
7.1 mV
5.2 mV
9.1 mV
6.1 mV
Pass
50% Load
8.3 mV
5.6 mV
8.8 mV
7.2 mV
Pass
60% Load
9.8 mV
5.4 mV
9.3 mV
6.5 mV
Pass
70% Load
12.4 mV
5.6 mV
9.4 mV
6.4 mV
Pass
80% Load
14.4 mV
5.8 mV
10.8 mV
7.4 mV
Pass
90% Load
16.5 mV
6.0 mV
10.3 mV
7.5 mV
Pass
100% Load
19.3 mV
6.9 mV
11.4 mV
8.0 mV
Pass
110% Load
22.3 mV
6.8 mV
12.1 mV
8.3 mV
Pass
Crossload 1
8.4 mV
5.5 mV
12.2 mV
7.2 mV
Pass
Crossload 2
19.1 mV
6.4 mV
11.2 mV
7.6 mV
Pass
The results above are not used in the certification process
be quiet! System Power U9 400W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted