This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.226
69.538%
0.040
5.029V
0.325
115.10V
2
0.090A
0.452
75.083%
0.072
5.028V
0.602
115.10V
3
0.550A
2.761
80.566%
0.289
5.019V
3.427
115.10V
4
1.000A
5.011
80.653%
0.375
5.010V
6.213
115.11V
5
1.500A
7.501
80.491%
0.421
5.000V
9.319
115.10V
6
3.000A
14.912
77.140%
0.483
4.970V
19.331
115.09V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.549A
2.004A
1.980A
0.999A
64.767
83.853%
0
<6.0
45.23°C
0.971
12.166V
4.988V
3.329V
5.008V
77.239
39.22°C
115.11V
2
8.094A
3.011A
2.974A
1.200A
129.287
88.113%
0
<6.0
46.23°C
0.976
12.156V
4.983V
3.326V
5.001V
146.728
39.44°C
115.10V
3
13.041A
3.517A
3.457A
1.402A
194.397
89.204%
436
7.6
40.71°C
0.978
12.146V
4.978V
3.324V
4.994V
217.923
48.05°C
115.10V
4
17.997A
4.024A
3.972A
1.605A
259.613
89.474%
436
7.6
40.82°C
0.983
12.136V
4.972V
3.321V
4.986V
290.155
49.23°C
115.10V
5
22.633A
5.036A
4.970A
1.808A
324.922
89.269%
436
7.6
41.60°C
0.987
12.125V
4.965V
3.318V
4.979V
363.980
50.89°C
115.10V
6
27.211A
6.050A
5.973A
2.012A
389.439
88.738%
608
8.9
42.64°C
0.989
12.114V
4.959V
3.315V
4.971V
438.863
52.36°C
115.10V
7
31.863A
7.070A
6.975A
2.217A
454.752
88.119%
1006
19.8
43.38°C
0.990
12.103V
4.952V
3.312V
4.963V
516.065
53.54°C
115.11V
8
36.523A
8.092A
7.980A
2.422A
520.077
87.338%
1431
31.4
44.12°C
0.991
12.093V
4.944V
3.308V
4.955V
595.473
54.70°C
115.16V
9
41.585A
8.608A
8.471A
2.424A
584.978
86.624%
1785
37.1
45.08°C
0.992
12.083V
4.937V
3.306V
4.952V
675.304
56.26°C
115.10V
10
46.398A
9.127A
8.994A
3.039A
649.821
85.780%
1790
37.2
46.71°C
0.993
12.072V
4.931V
3.302V
4.936V
757.546
58.45°C
115.10V
11
51.815A
9.136A
8.997A
3.041A
714.646
84.910%
1790
37.2
47.15°C
0.993
12.061V
4.927V
3.300V
4.933V
841.654
59.71°C
115.09V
CL1
0.138A
12.000A
11.998A
0.000A
101.114
82.959%
435
7.6
43.96°C
0.984
12.152V
4.970V
3.317V
5.015V
121.884
54.14°C
115.10V
CL2
54.005A
1.002A
0.998A
1.000A
665.364
86.336%
1793
37.2
46.76°C
0.993
12.075V
4.951V
3.314V
4.986V
770.670
58.54°C
115.09V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.187A
0.501A
0.477A
0.199A
19.540
69.602%
0
<6.0
0.869
12.173V
4.994V
3.332V
5.027V
28.074
115.13V
2
2.434A
1.002A
0.988A
0.398A
39.914
80.025%
0
<6.0
0.947
12.171V
4.991V
3.331V
5.022V
49.877
115.13V
3
3.614A
1.504A
1.472A
0.598A
59.379
83.851%
0
<6.0
0.971
12.168V
4.989V
3.329V
5.017V
70.815
115.11V
4
4.866A
2.007A
1.979A
0.798A
79.790
85.931%
0
<6.0
0.979
12.165V
4.987V
3.328V
5.012V
92.854
115.11V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
16.1 mV
12.5 mV
22.6 mV
6.5 mV
Pass
20% Load
8.7 mV
15.2 mV
21.4 mV
8.3 mV
Pass
30% Load
8.2 mV
19.3 mV
26.5 mV
9.9 mV
Pass
40% Load
11.2 mV
30.1 mV
22.9 mV
12.9 mV
Pass
50% Load
11.7 mV
34.5 mV
24.8 mV
17.4 mV
Pass
60% Load
11.6 mV
39.8 mV
26.3 mV
15.5 mV
Pass
70% Load
11.5 mV
17.3 mV
29.0 mV
18.4 mV
Pass
80% Load
13.0 mV
13.9 mV
22.7 mV
20.4 mV
Pass
90% Load
13.9 mV
15.9 mV
23.0 mV
21.3 mV
Pass
100% Load
19.1 mV
17.6 mV
29.9 mV
29.7 mV
Pass
110% Load
25.1 mV
28.3 mV
47.1 mV
43.3 mV
Pass
Crossload 1
12.7 mV
13.7 mV
24.3 mV
9.3 mV
Pass
Crossload 2
20.5 mV
15.5 mV
28.8 mV
21.4 mV
Pass
The results above are not used in the certification process