| Average Efficiency (>1450 load combinations) | 90.822% |
| Average Noise Output (>1450 Load Combinations) | 21.34dBA |
| Average PF (>1450 Load Combinations) | 0.941 |
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 72.582% |
| Standby Power Consumption | 0.0589W |
| 12V Ripple (Full Load) | 45.94mV |
| 5V Ripple (Full Load) | 34.84mV |
| 3.3V Ripple (Full Load) | 30.95mV |
| 5VSB Ripple (Full Load) | 24.76mV |
| 12V Load Regulation | 0.66% |
| 5V Load Regulation | 0.62% |
| 3.3V Load Regulation | 0.72% |
| 5VSB Load Regulation | 4.17% |
| Inrush Current | 53.450A |
| 12V Transient Response (200%) | 11.33V |
| 5V Transient Response (200%) | 4.920V |
| 3.3V Transient Response (200%) | 3.212V |
| 5VSB Transient Response (200%) | 4.958V |
| Hold-Up Time & PWR_OK Signal | 19.00ms |
| AC Loss to PWR_OK Hold Up Time | 16.70ms |
| PWR_OK Inactive to DC Loss Delay | 2.30ms |
| PSU Timings: T1 (20% / 100%) | 105.0ms | 107.0ms |
| PSU Timings: T3 (20% / 100%) | 126.0ms | 125.0ms |
| 12V OCP (29.2°C / 42.0°C) | 81.300A (130.08%), 11.974V — shut down | 79.500A (127.20%), 11.969V — shut down |
| 5V OCP (29.2°C / 42.0°C) | 28.300A (141.50%), 4.973V — shut down | 28.000A (140.00%), 4.972V — shut down |
| 3.3V OCP (29.2°C / 42.0°C) | 27.500A (137.50%), 3.292V — shut down | 25.900A (129.50%), 3.292V — shut down |
| 5VSB OCP (29.2°C / 42.0°C) | 4.800A (160.00%), 4.923V — shut down | 4.800A (160.00%), 4.921V — shut down |
| OPP (29.15°C / 42.39°C) | 128.08% | 122.94% |