This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232W
63.57%
0.127
5.16V
0.365W
114.85V
2
0.09A
0.464W
69.562%
0.202
5.158V
0.667W
114.85V
3
0.55A
2.828W
79.183%
0.381
5.142V
3.572W
114.84V
4
1A
5.126W
79.5%
0.413
5.125V
6.447W
114.83V
5
1.5A
7.662W
79.636%
0.437
5.107V
9.621W
114.83V
6
2A
10.18W
79.476%
0.453
5.089V
12.809W
114.83V
Supplementary Tests (For Reference)
115V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
3.616A
1.993A
1.989A
0.978A
65.004
83.06%
1010
23.8
40.01°C
0.967
12.002V
5.018V
3.318V
5.113V
78.26
42.63°C
114.81V
20%
8.270A
3.004A
3.004A
1.179A
129.938
86.999%
1008
23.8
40.93°C
0.972
11.975V
4.994V
3.296V
5.091V
149.357
44.47°C
114.8V
30%
13.298A
3.519A
3.524A
1.381A
194.94
87.621%
1012
23.8
41.01°C
0.97
11.947V
4.974V
3.277V
5.071V
222.482
45.57°C
114.77V
40%
18.361A
4.038A
4.052A
1.585A
260.027
86.903%
1736
40.9
41.82°C
0.978
11.918V
4.953V
3.258V
5.049V
299.215
45.19°C
114.76V
50%
23.092A
5.073A
5.099A
1.791A
325.027
86.108%
2134
48.8
42.08°C
0.982
11.888V
4.929V
3.236V
5.026V
377.467
45.62°C
114.74V
60%
27.795A
6.12A
6.163A
1.999A
389.392
85.272%
2158
49.2
42.51°C
0.985
11.858V
4.902V
3.213V
5.003V
456.646
47.48°C
114.7V
70%
32.612A
7.185A
7.252A
2.21A
454.712
84.176%
2157
49.1
43.48°C
0.987
11.824V
4.872V
3.186V
4.978V
540.204
50.28°C
114.67V
80%
37.456A
8.255A
8.35A
2.321A
519.519
82.955%
2159
49.2
43.59°C
0.988
11.791V
4.845V
3.161V
4.956V
626.267
51.71°C
114.65V
90%
42.749A
8.82A
8.927A
2.433A
584.945
81.551%
2158
49.2
43.76°C
0.989
11.754V
4.819V
3.136V
4.934V
717.273
54.04°C
114.62V
100%
48.212A
9.394A
9.55A
2A
649.435
79.947%
2159
49.2
44.24°C
0.99
11.717V
4.79V
3.11V
4.931V
812.334
57.13°C
114.6V
CL1
0.116A
12.653A
12.653A
0A
104.292
80.626%
1014
23.9
41.49°C
0.977
11.978V
4.9V
3.232V
5.113V
129.382
47.34°C
114.8V
CL2
0.116A
20.54A
0A
0A
101.336
78.969%
998
23.5
40.52°C
0.978
11.988V
4.866V
3.27V
5.123V
128.319
46.29°C
114.81V
CL3
0.115A
0A
16.222A
0A
54.183
74.62%
1004
23.7
40.42°C
0.967
11.997V
4.985V
3.254V
5.131V
72.612
44.53°C
114.82V
CL4
55.380A
0.001A
0.001A
0.003A
649.598
80.975%
2165
49.3
45.14°C
0.99
11.729V
4.882V
3.175V
5.03V
802.15
55°C
114.59V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.236A
0.496A
0.494A
0.194A
19.999
73.068%
1004
23.7
36.01°C
0.874
12.021V
5.043V
3.339V
5.152V
27.368
38.29°C
114.81V
40W
2.722A
0.695A
0.693A
0.292A
40
79.506%
1005
23.7
37.09°C
0.94
12.012V
5.037V
3.332V
5.144V
50.314
39.59°C
114.83V
60W
4.210A
0.894A
0.893A
0.389A
60
83.42%
1007
23.8
38.06°C
0.965
12.004V
5.03V
3.326V
5.137V
71.925
40.61°C
114.82V
80W
5.694A
1.095A
1.093A
0.487A
79.943
85.439%
1009
23.8
39.37°C
0.965
11.996V
5.023V
3.32V
5.129V
93.566
41.8°C
114.82V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
23.1 mV
19.3 mV
25.5 mV
21.9 mV
Pass
20% Load
24.1 mV
20.5 mV
28.4 mV
23.0 mV
Pass
30% Load
30.6 mV
23.5 mV
32.6 mV
24.3 mV
Pass
40% Load
39.5 mV
24.6 mV
34.8 mV
26.2 mV
Pass
50% Load
42.1 mV
25.5 mV
40.0 mV
28.3 mV
Pass
60% Load
46.7 mV
30.0 mV
44.9 mV
29.1 mV
Pass
70% Load
46.8 mV
28.0 mV
45.5 mV
26.9 mV
Pass
80% Load
51.4 mV
35.1 mV
55.6 mV
32.0 mV
Fail
90% Load
48.7 mV
36.4 mV
60.0 mV
29.7 mV
Fail
100% Load
79.1 mV
41.5 mV
73.6 mV
37.8 mV
Fail
110% Load
11.1 mV
8.8 mV
8.9 mV
7.4 mV
Pass
Crossload 1
45.6 mV
30.9 mV
52.8 mV
16.2 mV
Fail
Crossload 2
30.1 mV
33.3 mV
48.8 mV
15.8 mV
Pass
Crossload 3
23.4 mV
32.9 mV
38.2 mV
12.0 mV
Pass
Crossload 4
77.9 mV
33.4 mV
54.7 mV
26.6 mV
Fail
The results above are not used in the certification process