53.00A (127.22%), 11.523V* *Stopped, high ripple (155.18mV)
52.00A (124.82%), 12.067V
5V OCP (27.3°C / 43.4°C)
24.9A (124.50%), 4.976V, high ripple (60.07mV)
23.281A (116.41%), 4.96V, high ripple (53.63mV)
3.3V OCP (27.3°C / 43.4°C)
25.6A (128.00%), 3.268V
23.7A (118.50%), 3.257V
5VSB OCP (27.3°C / 43.4°C)
3.8A (126.67%), 5.035V
3.7A (123.33%), 5.032V
OPP (27.44°C / 42.17°C)
124.51%
124.51%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
13.3
AC Loss to PWR_OK Hold Up Time (ms)
11.1
PWR_OK Inactive to DC Loss Delay (ms)
2.2
Vampire Power
Tables 230V
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.04 V
230.94 V
227.70 V
231.12 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.28 %
2.00 %
PASS
Real Power:
0.113 W
0.077 W
N/A
0.169 W
N/A
N/A
Apparent Power:
21.594 W
21.208 W
N/A
21.958 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
53.362%
0.018
5.114V
0.432W
229.94V
2
0.09A
0.46W
60.727%
0.032
5.113V
0.758W
229.97V
3
0.55A
2.807W
77.079%
0.14
5.103V
3.642W
229.94V
4
1A
5.094W
78.552%
0.218
5.094V
6.485W
229.94V
5
1.5A
7.625W
78.573%
0.252
5.083V
9.704W
229.94V
6
3A
15.153W
77.008%
0.346
5.051V
19.679W
229.94V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
2.318A
1.957A
1.977A
0.984A
49.996
82.792%
776
15.9
40.3°C
0.809
12.252V
5.109V
3.339V
5.083V
60.388
42.22°C
229.93V
20%
5.642A
2.945A
2.975A
1.183A
99.923
87.837%
777
15.9
40.88°C
0.906
12.233V
5.094V
3.327V
5.07V
113.761
43.59°C
229.92V
30%
9.326A
3.443A
3.481A
1.384A
149.953
89.197%
782
16
41.13°C
0.947
12.214V
5.083V
3.318V
5.057V
168.114
44.77°C
229.91V
40%
13.022A
3.945A
3.99A
1.586A
199.988
89.353%
880
19.1
41.75°C
0.965
12.194V
5.071V
3.308V
5.045V
223.816
46.18°C
229.9V
50%
16.382A
4.947A
5.005A
1.789A
249.936
89.177%
1095
26.1
42.24°C
0.973
12.174V
5.054V
3.297V
5.031V
280.275
46.22°C
229.89V
60%
19.760A
5.954A
6.027A
1.993A
299.968
88.71%
1234
28.8
42.7°C
0.979
12.154V
5.039V
3.286V
5.017V
338.147
45.64°C
229.89V
70%
23.152A
6.971A
7.059A
2.199A
350.02
88.086%
1401
33.2
43.11°C
0.982
12.133V
5.022V
3.273V
5.002V
397.363
46.68°C
229.88V
80%
26.553A
7.992A
8.098A
2.305A
399.509
87.31%
1520
35.2
43.8°C
0.985
12.112V
5.005V
3.26V
4.989V
457.577
47.98°C
229.87V
90%
30.368A
8.512A
8.616A
2.411A
449.687
86.579%
1629
37.2
44.46°C
0.986
12.091V
4.993V
3.249V
4.978V
519.394
49.84°C
229.86V
100%
33.932A
9.034A
9.17A
3.026A
499.267
85.68%
1709
39.3
45.45°C
0.987
12.070V
4.981V
3.239V
4.957V
582.716
51.16°C
229.85V
110%
37.447A
10.075A
10.324A
3.033A
549.472
84.67%
1788
39.7
46.49°C
0.989
12.049V
4.963V
3.225V
4.946V
648.96
53.52°C
229.84V
CL1
0.113A
13.294A
13.35A
0A
111.282
82.557%
851
20.5
40.21°C
0.934
12.222V
4.98V
3.273V
5.067V
134.795
44.9°C
229.92V
CL2
0.113A
20.076A
0A
0A
101.355
81.897%
781
16
40.07°C
0.925
12.235V
4.98V
3.299V
5.082V
123.756
44.33°C
229.92V
CL3
0.113A
0A
20.146A
0A
67.38
76.573%
773
15.8
40.19°C
0.881
12.230V
5.034V
3.276V
5.074V
87.993
43.86°C
229.93V
CL4
41.401A
0A
0A
0A
499.868
86.699%
1690
39
45.38°C
0.987
12.074V
5.057V
3.283V
5.043V
576.556
50.91°C
229.85V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.211A
0.488A
0.492A
0.196A
20.005
74.597%
769
15.9
36.73°C
0.587
12.265V
5.128V
3.353V
5.107V
26.818
37.81°C
229.95V
40W
2.668A
0.683A
0.69A
0.294A
40.004
81.804%
771
15.6
37.33°C
0.752
12.256V
5.123V
3.348V
5.101V
48.905
39.24°C
229.94V
60W
4.125A
0.879A
0.888A
0.392A
59.999
85.606%
771
15.6
38.5°C
0.841
12.249V
5.119V
3.345V
5.096V
70.088
39.96°C
229.93V
80W
5.580A
1.075A
1.086A
0.491A
79.934
87.553%
771
15.6
39.43°C
0.887
12.242V
5.115V
3.341V
5.091V
91.299
41.64°C
229.92V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.48mV
16.38mV
16.34mV
10.38mV
Pass
20% Load
12.38mV
16.79mV
16.39mV
10.63mV
Pass
30% Load
14.02mV
17.36mV
17.17mV
11.10mV
Pass
40% Load
15.83mV
17.21mV
17.63mV
11.46mV
Pass
50% Load
18.31mV
18.24mV
18.10mV
11.92mV
Pass
60% Load
17.12mV
19.06mV
19.44mV
11.92mV
Pass
70% Load
18.87mV
20.30mV
20.27mV
13.42mV
Pass
80% Load
19.64mV
22.31mV
22.08mV
15.54mV
Pass
90% Load
22.17mV
23.03mV
22.24mV
14.81mV
Pass
100% Load
27.59mV
25.62mV
25.85mV
19.20mV
Pass
110% Load
33.32mV
27.86mV
27.79mV
20.51mV
Pass
Crossload1
14.98mV
29.80mV
29.74mV
13.75mV
Pass
Crossload2
16.55mV
44.66mV
19.65mV
10.68mV
Pass
Crossload3
15.00mV
17.36mV
39.09mV
14.55mV
Pass
Crossload4
31.40mV
20.76mV
19.69mV
14.27mV
Pass
The results above are not used in the certification process
Zalman GV2SE 500W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case