This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
230V
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 230V input. For this graph, the results of the 10-100% load regulation table are used
This graph depicts the efficiency levels of the 12VSB rail with 230V input
230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.54W
33.152%
0.071
11.996V
4.743W
229.84V
2
0.09A
1.08W
40.02%
0.082
11.993V
5.508W
229.84V
3
0.55A
6.582W
41.841%
0.165
11.966V
11.539W
229.84V
4
1A
11.942W
41.438%
0.228
11.941V
17.44W
229.84V
5
1.5A
17.873W
56.512%
0.313
11.914V
24.439W
229.84V
6
2A
23.777W
67.134%
0.38
11.886V
31.465W
229.83V
Supplementary Tests (For Reference)
230V
Test
Main Rail
Standby Rail
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
10%
4.904A
0.418A
269.967
91.735%
35.2°C
0.952
54.023V
11.969V
294.271
37.71°C
229.79V
20%
9.877A
0.502A
539.505
95.046%
35.85°C
0.984
54.012V
11.959V
567.669
37.97°C
229.76V
30%
14.867A
0.586A
809.781
95.412%
36.16°C
0.994
53.998V
11.948V
848.499
39.69°C
229.7V
40%
19.865A
0.67A
1080.501
95.639%
36.65°C
0.996
53.990V
11.938V
1129.772
40.93°C
229.67V
50%
24.857A
0.755A
1350.8
95.555%
37.07°C
0.997
53.982V
11.927V
1413.642
41.81°C
229.63V
60%
29.845A
0.839A
1620.803
95.295%
35.97°C
0.998
53.973V
11.916V
1700.862
42.39°C
229.58V
70%
34.838A
0.924A
1891.004
94.96%
35.1°C
0.998
53.964V
11.905V
1991.352
42.59°C
229.52V
80%
39.832A
0.967A
2160.343
94.758%
32.06°C
0.998
53.948V
11.895V
2279.84
38.9°C
229.49V
90%
44.844A
1.01A
2430.865
94.298%
33.98°C
0.998
53.939V
11.887V
2577.4
41.91°C
229.43V
100%
49.610A
2.03A
2699.74
94.799%
35.75°C
0.988
53.930V
11.824V
2874.2
42.26°C
229.54V
The results above are not used in the certification process
230V
Test
Main Rail
Standby Rail
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
20W
0.352A
0.083A
20.009
48.871%
30.98°C
0.342
54.027V
11.994V
28.598
33.38°C
229.84V
40W
0.712A
0.125A
40.013
78.392%
31.07°C
0.54
54.033V
11.991V
51.065
33.56°C
229.85V
60W
1.074A
0.167A
60.012
81.664%
32.19°C
0.687
54.031V
11.988V
73.474
34.74°C
229.82V
80W
1.433A
0.209A
79.916
83.48%
33.03°C
0.763
54.030V
11.985V
95.712
35.41°C
229.82V
The results above are not used in the certification process
230V
Test
Main Rail
Standby Rail
Pass/Fail (Limit: 540mV)
10% Load
79.1 mV
43.4 mV
Pass
20% Load
110.0 mV
47.8 mV
Pass
30% Load
77.4 mV
48.1 mV
Pass
40% Load
113.3 mV
57.9 mV
Pass
50% Load
120.2 mV
58.7 mV
Pass
60% Load
134.3 mV
72.8 mV
Pass
70% Load
147.3 mV
81.8 mV
Pass
80% Load
157.3 mV
77.1 mV
Pass
90% Load
164.1 mV
86.0 mV
Pass
100% Load
143.7 mV
112.4 mV
Pass
The results above are not used in the certification process