This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 230V input. For this graph, the results of the 10-100% load regulation table are used
5VSB Efficiency
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
Main Rail
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
10%
12.950A
160.002
90.044%
35.48°C
0.956
12.356V
177.696
39.75°C
229.81V
20%
25.955A
320.029
93.921%
35.9°C
0.985
12.331V
340.753
40.33°C
229.79V
30%
39.000A
479.932
93.965%
36.12°C
0.993
12.306V
510.776
40.88°C
229.77V
40%
52.104A
639.989
93.851%
36.81°C
0.996
12.283V
681.902
42.47°C
229.73V
50%
65.260A
800.001
93.517%
37.46°C
0.998
12.259V
855.455
42.34°C
229.71V
60%
78.466A
960.052
92.95%
37.66°C
0.999
12.236V
1032.854
44.64°C
229.68V
70%
91.715A
1120.123
92.239%
38.48°C
0.999
12.213V
1214.491
46.53°C
229.64V
80%
105.023A
1280.146
91.522%
38.79°C
0.999
12.189V
1398.748
46.73°C
229.63V
90%
118.403A
1440.131
90.781%
39.46°C
0.999
12.163V
1586.178
49.43°C
229.6V
100%
131.869A
1600.159
89.755%
40.87°C
0.999
12.134V
1782.659
49.93°C
229.58V
The results above are not used in the certification process
Light Load Tests 230V
Test
Main Rail
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
20W
1.618A
20.019
72.968%
30.79°C
0.508
12.377V
27.522
35.5°C
229.84V
40W
3.232A
40.005
82.478%
31.05°C
0.671
12.374V
48.572
34.13°C
229.85V
60W
4.850A
60.005
85.304%
32.79°C
0.815
12.373V
70.409
35.38°C
229.83V
80W
6.466A
79.994
86.274%
33.5°C
0.88
12.372V
92.644
36.57°C
229.82V
100W
8.086A
99.993
87.555%
34.61°C
0.911
12.367V
114.214
38.07°C
229.83V
The results above are not used in the certification process
Ripple Measurements 230V
Test
Main Rail
Pass/Fail
10% Load
29.3 mV
Pass
20% Load
31.5 mV
Pass
30% Load
39.3 mV
Pass
40% Load
43.7 mV
Pass
50% Load
47.7 mV
Pass
60% Load
53.0 mV
Pass
70% Load
54.9 mV
Pass
80% Load
66.7 mV
Pass
90% Load
64.4 mV
Pass
100% Load
87.5 mV
Pass
The results above are not used in the certification process
Great Wall CRPS1600D2W
Top side
Power specifications label
ybenetics bietet die freiwilligen ETA- und Lambda-Zertifizierungsprogramme an, mit denen effiziente und leise Netzteile (PSU) beworben werden