This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.224
66.272%
0.029
4.973V
0.338
115.27V
2
0.090A
0.447
72.447%
0.052
4.971V
0.617
115.28V
3
0.550A
2.723
79.994%
0.237
4.951V
3.404
115.26V
4
1.000A
4.931
79.919%
0.341
4.932V
6.170
115.26V
5
1.500A
7.366
80.065%
0.405
4.911V
9.200
115.26V
6
2.999A
14.543
78.692%
0.490
4.849V
18.481
115.24V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.180A
1.986A
1.987A
0.998A
84.686
91.364%
0
<6.0
43.20°C
0.966
12.180V
5.032V
3.321V
5.011V
92.691
38.07°C
115.27V
2
11.357A
2.979A
2.980A
1.198A
169.185
93.639%
0
<6.0
43.51°C
0.990
12.178V
5.031V
3.320V
5.007V
180.678
38.18°C
115.16V
3
17.928A
3.478A
3.465A
1.399A
254.306
93.955%
395
10.5
38.54°C
0.996
12.177V
5.031V
3.319V
5.003V
270.669
44.55°C
115.03V
4
24.503A
3.976A
3.977A
1.601A
339.521
93.626%
395
10.5
38.83°C
0.992
12.175V
5.030V
3.318V
4.998V
362.636
44.93°C
115.02V
5
30.748A
4.971A
4.971A
1.802A
424.851
93.098%
435
10.7
38.98°C
0.992
12.175V
5.030V
3.317V
4.995V
456.347
45.33°C
114.91V
6
36.933A
5.966A
5.968A
2.004A
509.381
92.667%
290
9.0
40.18°C
0.993
12.173V
5.029V
3.316V
4.991V
549.688
46.75°C
114.80V
7
43.179A
6.961A
6.966A
2.206A
594.717
92.092%
415
10.0
41.44°C
0.995
12.173V
5.028V
3.316V
4.987V
645.784
48.48°C
114.77V
8
49.430A
7.957A
7.963A
2.408A
680.069
91.510%
490
13.3
42.30°C
0.995
12.172V
5.028V
3.315V
4.984V
743.166
49.76°C
114.64V
9
56.076A
8.455A
8.447A
2.408A
764.999
91.252%
590
17.4
43.92°C
0.996
12.171V
5.027V
3.314V
4.984V
838.337
52.03°C
114.53V
10
62.465A
8.954A
8.962A
3.020A
849.855
90.651%
900
29.6
45.17°C
0.997
12.169V
5.027V
3.314V
4.969V
937.498
53.52°C
114.49V
11
69.443A
8.954A
8.965A
3.020A
934.620
89.948%
1355
41.6
46.88°C
0.997
12.167V
5.027V
3.312V
4.968V
1039.063
55.55°C
114.35V
CL1
0.737A
12.002A
11.999A
0.000A
109.245
89.765%
460
11.9
43.78°C
0.980
12.181V
5.031V
3.324V
5.058V
121.701
47.82°C
115.22V
CL2
70.004A
1.001A
1.001A
1.000A
865.094
90.829%
900
29.6
45.20°C
0.997
12.167V
5.029V
3.313V
5.004V
952.443
50.78°C
114.47V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.165A
0.491A
0.479A
0.199A
19.242
75.711%
0
<6.0
0.784
12.168V
5.037V
3.323V
5.032V
25.415
115.35V
2
2.414A
0.991A
0.990A
0.398A
39.677
86.416%
0
<6.0
0.902
12.179V
5.034V
3.321V
5.025V
45.914
115.32V
3
3.598A
1.486A
1.473A
0.598A
59.197
89.620%
0
<6.0
0.947
12.180V
5.033V
3.321V
5.021V
66.053
115.30V
4
4.848A
1.985A
1.987A
0.797A
79.633
91.190%
0
<6.0
0.962
12.180V
5.032V
3.321V
5.016V
87.326
115.28V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
11.8 mV
3.2 mV
3.8 mV
2.5 mV
Pass
20% Load
14.1 mV
3.2 mV
4.1 mV
2.7 mV
Pass
30% Load
8.9 mV
3.4 mV
4.3 mV
3.1 mV
Pass
40% Load
9.9 mV
3.5 mV
4.7 mV
3.4 mV
Pass
50% Load
10.6 mV
4.2 mV
5.4 mV
4.3 mV
Pass
60% Load
12.1 mV
4.9 mV
5.8 mV
4.3 mV
Pass
70% Load
13.5 mV
5.1 mV
5.8 mV
4.5 mV
Pass
80% Load
14.9 mV
4.9 mV
6.6 mV
4.7 mV
Pass
90% Load
16.4 mV
5.0 mV
7.3 mV
5.4 mV
Pass
100% Load
16.9 mV
5.4 mV
7.5 mV
6.0 mV
Pass
110% Load
17.7 mV
5.8 mV
8.2 mV
6.6 mV
Pass
Crossload 1
13.0 mV
5.4 mV
7.2 mV
3.2 mV
Pass
Crossload 2
17.2 mV
3.4 mV
5.0 mV
5.3 mV
Pass
The results above are not used in the certification process