This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
67.941%
0.032
5.130V
0.340
115.26V
2
0.090A
0.461
72.943%
0.059
5.129V
0.632
115.27V
3
0.550A
2.815
77.677%
0.265
5.118V
3.624
115.26V
4
1.000A
5.108
77.547%
0.361
5.108V
6.587
115.25V
5
1.500A
7.646
77.759%
0.412
5.098V
9.833
115.25V
6
3.000A
15.157
76.331%
0.478
5.053V
19.857
115.24V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.177A
1.991A
1.984A
0.980A
84.619
87.552%
0
<6.0
44.91°C
0.945
12.178V
5.013V
3.321V
5.105V
96.650
38.02°C
115.17V
2
11.350A
2.990A
2.977A
1.177A
169.116
91.040%
0
<6.0
45.88°C
0.985
12.180V
5.013V
3.321V
5.096V
185.761
38.37°C
115.16V
3
17.917A
3.489A
3.462A
1.376A
254.233
91.863%
0
<6.0
46.79°C
0.994
12.181V
5.014V
3.320V
5.087V
276.752
38.84°C
115.04V
4
24.479A
3.987A
3.975A
1.576A
339.437
91.626%
550
10.8
39.22°C
0.992
12.184V
5.013V
3.320V
5.077V
370.458
47.59°C
114.92V
5
30.714A
4.988A
4.971A
1.776A
424.776
91.241%
445
9.5
39.73°C
0.992
12.186V
5.012V
3.318V
5.068V
465.552
48.55°C
114.91V
6
36.880A
5.987A
5.969A
1.977A
509.289
90.814%
465
9.8
40.48°C
0.993
12.188V
5.011V
3.316V
5.059V
560.807
49.51°C
114.79V
7
43.116A
6.984A
6.966A
2.179A
594.625
90.300%
900
21.8
41.73°C
0.993
12.189V
5.010V
3.315V
5.049V
658.498
51.29°C
114.66V
8
49.358A
7.988A
7.966A
2.382A
679.973
89.719%
1495
32.0
42.92°C
0.994
12.188V
5.008V
3.313V
5.039V
757.893
52.87°C
114.64V
9
55.989A
8.489A
8.453A
2.384A
764.896
89.316%
2025
41.2
44.70°C
0.994
12.188V
5.007V
3.312V
5.034V
856.396
55.04°C
114.50V
10
62.359A
8.989A
8.971A
2.991A
849.734
88.711%
2035
41.3
45.66°C
0.995
12.188V
5.006V
3.311V
5.015V
957.872
57.09°C
114.47V
11
69.302A
8.990A
8.971A
2.994A
934.493
88.015%
2055
41.4
47.13°C
0.995
12.190V
5.006V
3.310V
5.011V
1061.741
59.62°C
114.33V
CL1
0.731A
12.000A
11.999A
0.000A
108.949
86.494%
465
9.8
43.68°C
0.968
12.185V
5.013V
3.324V
5.118V
125.961
52.87°C
115.22V
CL2
69.995A
1.001A
0.997A
1.000A
866.620
89.045%
2035
41.3
45.50°C
0.995
12.190V
5.009V
3.311V
5.066V
973.236
56.68°C
114.45V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.160A
0.497A
0.479A
0.195A
19.208
70.545%
0
<6.0
0.596
12.175V
5.017V
3.324V
5.125V
27.228
115.25V
2
2.411A
0.995A
0.991A
0.391A
39.632
80.697%
0
<6.0
0.821
12.175V
5.011V
3.320V
5.120V
49.112
115.23V
3
3.594A
1.493A
1.473A
0.587A
59.138
84.900%
0
<6.0
0.895
12.176V
5.012V
3.321V
5.115V
69.656
115.20V
4
4.843A
1.993A
1.984A
0.783A
79.557
87.132%
0
<6.0
0.936
12.178V
5.013V
3.321V
5.109V
91.306
115.17V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.3 mV
5.8 mV
5.5 mV
4.2 mV
Pass
20% Load
9.4 mV
6.8 mV
6.2 mV
4.5 mV
Pass
30% Load
11.5 mV
7.3 mV
6.8 mV
5.0 mV
Pass
40% Load
13.8 mV
8.0 mV
7.5 mV
5.8 mV
Pass
50% Load
15.2 mV
8.3 mV
8.3 mV
5.4 mV
Pass
60% Load
13.6 mV
9.3 mV
8.6 mV
6.1 mV
Pass
70% Load
13.4 mV
9.9 mV
9.4 mV
6.5 mV
Pass
80% Load
14.0 mV
10.2 mV
10.2 mV
6.7 mV
Pass
90% Load
16.0 mV
11.1 mV
10.6 mV
6.9 mV
Pass
100% Load
17.3 mV
11.8 mV
12.0 mV
7.8 mV
Pass
110% Load
19.5 mV
12.1 mV
12.1 mV
9.8 mV
Pass
Crossload 1
7.5 mV
11.5 mV
11.0 mV
3.9 mV
Pass
Crossload 2
18.0 mV
7.4 mV
7.2 mV
7.3 mV
Pass
The results above are not used in the certification process
Seasonic Focus Plus Platinum 850W
Top side
Power specifications label
ybenetics bietet die freiwilligen ETA- und Lambda-Zertifizierungsprogramme an, mit denen effiziente und leise Netzteile (PSU) beworben werden