This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232W
65.894%
0.027
5.156V
0.352W
115.16V
2
0.09A
0.464W
72.676%
0.048
5.155V
0.639W
115.15V
3
0.55A
2.83W
80.721%
0.218
5.145V
3.506W
115.15V
4
1A
5.137W
81.147%
0.309
5.136V
6.331W
115.15V
5
1.5A
7.689W
81.725%
0.366
5.125V
9.409W
115.15V
6
2.5A
12.762W
80.085%
0.427
5.104V
15.936W
115.15V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.514A
1.961A
1.958A
0.976A
100.009
86.767%
940
29.7
34.01°C
0.969
12.037V
5.1V
3.37V
5.126V
115.259
38.07°C
115.14V
20%
14.044A
2.949A
2.947A
1.173A
199.961
90.218%
941
29.7
34.68°C
0.979
12.037V
5.088V
3.36V
5.114V
221.643
38.93°C
115.11V
30%
21.944A
3.447A
3.448A
1.372A
300.013
91.171%
947
29.9
35.38°C
0.988
12.029V
5.077V
3.35V
5.102V
329.066
40.11°C
115.08V
40%
29.824A
3.949A
3.951A
1.572A
399.729
91.212%
1028
32.4
35.46°C
0.992
12.021V
5.066V
3.341V
5.091V
438.243
40.46°C
115.06V
50%
37.373A
4.948A
4.955A
1.772A
499.462
90.737%
1235
37.7
36.29°C
0.994
12.013V
5.053V
3.33V
5.079V
550.447
41.79°C
115.04V
60%
44.998A
5.953A
5.967A
1.974A
600.019
90.012%
1390
40.9
36.89°C
0.995
12.005V
5.04V
3.318V
5.066V
666.607
42.95°C
115.01V
70%
52.570A
6.964A
6.986A
2.177A
699.766
89.224%
1538
43.4
37.34°C
0.996
11.996V
5.027V
3.307V
5.053V
784.286
44.44°C
114.98V
80%
60.220A
7.979A
8.011A
2.281A
799.801
88.427%
1656
45.0
38.06°C
0.996
11.988V
5.013V
3.295V
5.043V
904.469
46.09°C
114.95V
90%
68.209A
8.499A
8.523A
2.385A
899.604
87.579%
1819
47.3
39.72°C
0.997
11.980V
5.001V
3.285V
5.033V
1027.191
48.75°C
114.93V
100%
76.273A
9.021A
9.07A
2.489A
1000.335
86.49%
1856
47.8
40.01°C
0.997
11.973V
4.989V
3.274V
5.023V
1156.603
50.11°C
114.89V
110%
83.940A
10.05A
10.21A
2.493A
1100.159
85.298%
1861
47.9
40.42°C
0.998
11.965V
4.975V
3.261V
5.014V
1289.784
51.34°C
114.86V
CL1
0.117A
11.861A
11.888A
0A
101.307
82.119%
1198
36.7
37.71°C
0.969
12.037V
5.076V
3.339V
5.13V
123.369
43.22°C
115.14V
CL2
0.116A
19.693A
0A
0A
101.397
82.026%
960
30.3
35.1°C
0.968
12.040V
5.078V
3.346V
5.143V
123.62
42.17°C
115.15V
CL3
0.116A
0A
19.724A
0A
67.392
75.662%
944
29.8
35.64°C
0.958
12.034V
5.09V
3.346V
5.129V
89.068
44.68°C
115.15V
CL4
83.495A
0A
0A
0.001A
1000.38
86.918%
1854
47.8
41.11°C
0.997
11.981V
5.016V
3.302V
5.086V
1150.958
51.99°C
114.89V
The results above are not used in the certification process
Light Load Tests 115V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.234A
0.489A
0.488A
0.194A
20.007
67.341%
939
29.7
30.42°C
0.773
12.043V
5.11V
3.381V
5.149V
29.709
33.47°C
115.16V
40W
2.714A
0.685A
0.684A
0.292A
40.003
78.8%
937
29.6
32.51°C
0.892
12.043V
5.109V
3.379V
5.145V
50.766
35.79°C
115.16V
60W
4.197A
0.881A
0.879A
0.389A
60
82.3%
939
29.7
33.38°C
0.943
12.040V
5.106V
3.377V
5.142V
72.904
37.11°C
115.15V
80W
5.676A
1.078A
1.076A
0.487A
79.956
85.827%
940
29.7
33.6°C
0.963
12.039V
5.104V
3.374V
5.138V
93.163
37.54°C
115.14V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.53mV
8.28mV
11.62mV
8.62mV
Pass
20% Load
23.58mV
9.26mV
13.10mV
9.59mV
Pass
30% Load
20.72mV
15.70mV
13.05mV
10.91mV
Pass
40% Load
21.69mV
11.81mV
15.46mV
12.13mV
Pass
50% Load
25.13mV
10.74mV
15.51mV
14.89mV
Pass
60% Load
25.03mV
11.66mV
16.48mV
15.70mV
Pass
70% Load
27.99mV
12.17mV
17.71mV
17.79mV
Pass
80% Load
31.16mV
13.20mV
21.24mV
18.00mV
Pass
90% Load
33.30mV
14.42mV
22.16mV
21.56mV
Pass
100% Load
50.48mV
16.43mV
25.43mV
24.85mV
Pass
110% Load
56.11mV
17.70mV
26.08mV
26.83mV
Pass
Crossload1
28.98mV
13.52mV
15.97mV
9.40mV
Pass
Crossload2
19.31mV
16.00mV
11.21mV
7.90mV
Pass
Crossload3
8.53mV
10.64mV
16.58mV
7.24mV
Pass
Crossload4
50.12mV
13.34mV
18.21mV
19.84mV
Pass
The results above are not used in the certification process
Aresgame AGT1000
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted