This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232W
59.679%
0.037
5.156V
0.389W
114.84V
2
0.09A
0.464W
70.023%
0.062
5.155V
0.663W
114.84V
3
0.55A
2.83W
83.387%
0.24
5.145V
3.394W
114.84V
4
1A
5.136W
84.232%
0.308
5.135V
6.097W
114.84V
5
1.5A
7.688W
84.016%
0.353
5.125V
9.15W
114.84V
6
3A
15.28W
82.7%
0.414
5.093V
18.475W
114.84V
Supplementary Tests (For Reference)
115V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.382A
1.934A
1.966A
0.976A
99.995
87.99%
0
<6.0
38.65°C
0.928
12.284V
5.169V
3.357V
5.124V
113.645
34.42°C
114.83V
20%
13.770A
2.91A
2.962A
1.175A
199.948
90.958%
0
<6.0
39.47°C
0.964
12.276V
5.154V
3.342V
5.106V
219.828
34.88°C
114.8V
30%
21.520A
3.404A
3.468A
1.376A
299.999
91.384%
0
<6.0
40.47°C
0.978
12.265V
5.142V
3.33V
5.089V
328.283
35.41°C
114.76V
40%
29.249A
3.898A
3.978A
1.578A
399.581
91.131%
802
18.2
35.85°C
0.985
12.253V
5.131V
3.318V
5.072V
438.472
41.38°C
114.73V
50%
36.671A
4.887A
4.996A
1.781A
499.284
90.778%
771
16.8
36.3°C
0.99
12.238V
5.116V
3.303V
5.054V
550.007
42.19°C
114.69V
60%
44.183A
5.882A
6.024A
1.986A
599.851
90.189%
1177
29.7
36.95°C
0.993
12.223V
5.101V
3.287V
5.035V
665.103
43.49°C
114.66V
70%
51.645A
6.884A
7.063A
2.193A
699.577
89.516%
1452
35.3
37.03°C
0.995
12.208V
5.085V
3.271V
5.017V
781.515
44.07°C
114.62V
80%
59.190A
7.892A
8.112A
2.3A
799.611
88.724%
1662
38.9
37.71°C
0.996
12.193V
5.07V
3.254V
5V
901.243
45.77°C
114.58V
90%
67.077A
8.405A
8.639A
2.409A
899.396
87.725%
1730
40.1
38.31°C
0.993
12.179V
5.057V
3.241V
4.983V
1025.238
47.34°C
114.55V
100%
74.786A
8.923A
9.203A
3.028A
999.405
87.033%
1730
40.1
39.53°C
0.996
12.165V
5.043V
3.227V
4.954V
1148.308
49.62°C
114.5V
110%
82.444A
9.952A
10.378A
3.039A
1100.035
85.956%
1730
40.1
40.05°C
0.997
12.150V
5.025V
3.208V
4.936V
1279.751
50.99°C
114.46V
CL1
0.114A
12.196A
12.463A
0A
104.308
80.771%
1073
26.6
34.14°C
0.932
12.281V
5.084V
3.282V
5.129V
129.144
39.66°C
114.81V
CL2
0.113A
19.699A
0A
0A
101.353
78.993%
0
<6.0
43.01°C
0.931
12.288V
5.074V
3.318V
5.136V
128.314
35.94°C
114.82V
CL3
0.113A
0A
20.246A
0A
67.385
71.72%
0
<6.0
43.68°C
0.913
12.277V
5.101V
3.26V
5.133V
93.96
34.65°C
114.83V
CL4
82.087A
0A
0A
0.008A
1000.002
87.686%
1739
40.2
39.23°C
0.995
12.181V
5.11V
3.294V
5.034V
1140.444
50.18°C
114.51V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.208A
0.482A
0.489A
0.194A
19.998
73.948%
0
<6.0
33.49°C
0.734
12.298V
5.188V
3.374V
5.151V
27.045
30.43°C
114.87V
40W
2.660A
0.675A
0.685A
0.292A
39.999
82.905%
0
<6.0
35.09°C
0.846
12.286V
5.184V
3.371V
5.146V
48.25
31.81°C
114.86V
60W
4.114A
0.868A
0.882A
0.389A
59.999
85.438%
0
<6.0
36.59°C
0.888
12.283V
5.181V
3.368V
5.142V
70.226
32.8°C
114.85V
80W
5.562A
1.062A
1.079A
0.487A
79.942
87.976%
0
<6.0
37.86°C
0.913
12.282V
5.177V
3.365V
5.137V
90.865
33.88°C
114.84V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
16.3 mV
14.3 mV
12.7 mV
9.6 mV
Pass
20% Load
14.7 mV
17.5 mV
14.1 mV
12.8 mV
Pass
30% Load
13.9 mV
19.7 mV
15.7 mV
16.7 mV
Pass
40% Load
15.0 mV
23.3 mV
16.0 mV
21.6 mV
Pass
50% Load
17.0 mV
27.5 mV
19.9 mV
25.4 mV
Pass
60% Load
18.8 mV
30.4 mV
21.7 mV
30.0 mV
Pass
70% Load
22.1 mV
34.7 mV
21.4 mV
34.5 mV
Pass
80% Load
23.2 mV
39.1 mV
23.1 mV
38.5 mV
Pass
90% Load
26.7 mV
40.4 mV
24.0 mV
44.4 mV
Pass
100% Load
33.2 mV
46.0 mV
27.8 mV
50.5 mV
Fail
110% Load
38.1 mV
50.6 mV
31.0 mV
54.3 mV
Fail
Crossload 1
24.0 mV
51.6 mV
35.6 mV
14.1 mV
Fail
Crossload 2
25.5 mV
35.0 mV
174.9 mV
14.4 mV
Fail
Crossload 3
18.5 mV
45.5 mV
17.8 mV
12.8 mV
Pass
Crossload 4
31.8 mV
18.4 mV
15.8 mV
50.8 mV
Fail
The results above are not used in the certification process