This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.227W
48.356%
0.02
5.032V
0.47W
229.91V
2
0.09A
0.453W
59.783%
0.033
5.031V
0.76W
229.91V
3
0.55A
2.764W
76.261%
0.143
5.025V
3.623W
229.89V
4
1A
5.02W
78.548%
0.219
5.019V
6.391W
229.89V
5
1.5A
7.52W
79.41%
0.272
5.013V
9.47W
229.89V
6
3A
14.982W
79.058%
0.357
4.993V
18.951W
229.89V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
5.540A
1.954A
1.972A
0.997A
90.016
83.164%
1627
44.2
35.67°C
0.894
12.350V
5.118V
3.348V
5.014V
108.237
39.92°C
229.88V
20%
12.082A
2.934A
2.961A
1.199A
179.972
87.594%
1542
43.3
35.82°C
0.944
12.338V
5.113V
3.344V
5.004V
205.458
40.48°C
229.88V
30%
18.982A
3.427A
3.463A
1.401A
270.034
88.638%
1699
45.5
36.18°C
0.963
12.326V
5.106V
3.336V
4.995V
304.645
41.19°C
229.85V
40%
25.897A
3.922A
3.966A
1.604A
360.109
88.897%
1698
45.5
36.51°C
0.974
12.314V
5.1V
3.329V
4.987V
405.094
41.83°C
229.85V
50%
32.465A
4.91A
4.969A
1.808A
449.893
88.668%
1694
45.5
37.24°C
0.98
12.301V
5.092V
3.321V
4.978V
507.393
42.94°C
229.84V
60%
39.079A
5.902A
5.979A
2A
539.984
88.22%
1693
45.4
37.98°C
0.984
12.289V
5.084V
3.312V
4.969V
612.087
44.18°C
229.82V
70%
45.704A
6.9A
6.996A
2.218A
630.189
87.677%
1692
45.4
38.54°C
0.987
12.276V
5.074V
3.303V
4.961V
718.773
45.56°C
229.81V
80%
52.347A
7.904A
8.022A
2.322A
719.854
87.018%
1696
45.5
39.12°C
0.989
12.263V
5.063V
3.291V
4.955V
827.252
47.27°C
229.8V
90%
59.393A
8.408A
8.527A
2.426A
810.078
86.325%
1702
45.5
39.36°C
0.991
12.249V
5.057V
3.284V
4.947V
938.405
48.53°C
229.79V
100%
66.192A
8.917A
9.07A
3.042A
899.646
85.456%
1696
45.5
40.16°C
0.993
12.236V
5.049V
3.275V
4.932V
1052.758
50.17°C
229.78V
110%
72.949A
9.928A
10.203A
3.046A
989.889
84.284%
1695
45.5
41.28°C
0.994
12.222V
5.039V
3.264V
4.926V
1174.481
52.15°C
229.76V
CL1
0.114A
14.234A
14.342A
0A
121.342
80.944%
1692
45.4
37.42°C
0.925
12.338V
5.074V
3.326V
5.02V
149.905
42.91°C
229.87V
CL3
0.113A
0A
19.803A
0A
67.394
74.666%
1610
44.4
39.85°C
0.872
12.342V
5.119V
3.332V
5.014V
90.264
47.91°C
229.88V
CL4
73.523A
0A
0A
0.002A
900.088
85.951%
1697
45.5
40.71°C
0.992
12.243V
5.086V
3.285V
4.98V
1047.222
50.64°C
229.77V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.202A
0.487A
0.491A
0.199A
20.003
66.897%
1195
36.9
33.23°C
0.655
12.363V
5.137V
3.358V
5.029V
29.9
36.3°C
229.9V
40W
2.646A
0.682A
0.688A
0.298A
40.004
76.013%
1209
37.1
33.69°C
0.785
12.359V
5.136V
3.358V
5.027V
52.627
37.01°C
229.9V
60W
4.090A
0.876A
0.885A
0.398A
60.005
81.22%
1226
37.7
34.1°C
0.844
12.355V
5.134V
3.357V
5.024V
73.88
37.59°C
229.9V
80W
5.532A
1.072A
1.082A
0.498A
79.962
83.031%
1435
41.5
34.9°C
0.88
12.352V
5.132V
3.355V
5.021V
96.306
38.74°C
229.89V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
14.69mV
8.48mV
7.67mV
8.29mV
Pass
20% Load
14.84mV
9.19mV
8.28mV
8.24mV
Pass
30% Load
15.92mV
9.65mV
8.74mV
9.31mV
Pass
40% Load
18.37mV
10.52mV
10.38mV
10.28mV
Pass
50% Load
21.96mV
11.85mV
10.33mV
11.36mV
Pass
60% Load
23.80mV
13.08mV
10.84mV
12.74mV
Pass
70% Load
28.40mV
14.15mV
12.22mV
14.38mV
Pass
80% Load
37.77mV
16.19mV
14.27mV
16.58mV
Pass
90% Load
44.37mV
19.20mV
30.63mV
18.68mV
Pass
100% Load
55.69mV
21.55mV
17.76mV
25.96mV
Pass
110% Load
62.33mV
23.77mV
19.14mV
29.25mV
Pass
Crossload1
20.61mV
24.23mV
17.29mV
10.41mV
Pass
Crossload2
0.00mV
0.00mV
0.00mV
0.00mV
Pass
Crossload3
17.86mV
24.11mV
17.08mV
9.26mV
Pass
Crossload4
55.78mV
14.51mV
12.86mV
22.47mV
Pass
The results above are not used in the certification process
Micronics Coolmax Focus II 900W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted