This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.213
67.834%
0.032
5.098V
0.314
115.11V
2
0.087A
0.445
74.916%
0.059
5.097V
0.594
115.11V
3
0.542A
2.757
79.338%
0.263
5.086V
3.475
115.12V
4
1.002A
5.086
78.066%
0.361
5.076V
6.515
115.12V
5
1.502A
7.607
77.949%
0.413
5.065V
9.759
115.12V
6
2.501A
12.615
75.679%
0.463
5.043V
16.669
115.11V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.391A
1.974A
1.968A
0.985A
74.810
87.021%
455
10.9
37.85°C
0.961
12.123V
5.063V
3.346V
5.075V
85.968
44.18°C
115.08V
2
9.816A
2.960A
2.957A
1.181A
149.789
90.542%
455
10.9
38.27°C
0.977
12.116V
5.062V
3.344V
5.069V
165.436
46.47°C
115.08V
3
15.594A
3.457A
3.469A
1.381A
224.893
91.490%
470
11.5
38.42°C
0.983
12.108V
5.060V
3.343V
5.063V
245.811
50.06°C
115.08V
4
21.369A
3.952A
3.951A
1.580A
299.784
91.494%
455
10.9
39.31°C
0.983
12.102V
5.058V
3.340V
5.057V
327.655
54.67°C
115.08V
5
26.808A
4.949A
4.939A
1.780A
374.749
91.243%
455
10.9
40.43°C
0.983
12.095V
5.057V
3.339V
5.050V
410.715
56.51°C
115.08V
6
32.254A
5.932A
5.930A
1.981A
449.626
90.107%
627
16.1
41.32°C
0.982
12.087V
5.055V
3.338V
5.044V
498.990
58.11°C
115.07V
7
37.713A
6.928A
6.924A
2.180A
524.616
89.214%
1165
33.0
42.33°C
0.983
12.079V
5.053V
3.335V
5.038V
588.042
59.31°C
115.07V
8
43.174A
7.915A
7.919A
2.384A
599.572
88.269%
1603
41.1
42.92°C
0.984
12.072V
5.052V
3.333V
5.031V
679.256
60.31°C
115.07V
9
49.068A
8.422A
8.434A
2.385A
674.636
87.446%
1800
44.4
44.11°C
0.986
12.065V
5.050V
3.332V
5.030V
771.493
61.58°C
115.06V
10
54.933A
8.919A
8.917A
2.485A
749.531
86.788%
1800
44.4
45.37°C
0.987
12.057V
5.048V
3.330V
5.025V
863.634
63.26°C
115.06V
11
61.177A
8.919A
8.922A
2.485A
824.383
85.942%
1800
44.4
47.36°C
0.989
12.050V
5.047V
3.329V
5.024V
959.237
65.79°C
115.07V
CL1
0.100A
14.026A
14.005A
0.004A
118.993
84.604%
570
13.6
44.29°C
0.975
12.103V
5.059V
3.342V
5.098V
140.647
58.95°C
115.10V
CL2
62.455A
1.003A
1.003A
1.002A
767.002
87.235%
1800
44.4
45.63°C
0.987
12.065V
5.052V
3.334V
5.061V
879.237
60.97°C
115.08V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.208A
0.491A
0.476A
0.196A
19.720
70.471%
455
10.9
0.863
12.119V
5.066V
3.349V
5.093V
27.983
115.08V
2
2.434A
0.979A
0.983A
0.391A
39.756
82.000%
455
10.9
0.927
12.127V
5.065V
3.347V
5.089V
48.483
115.08V
3
3.667A
1.476A
1.492A
0.590A
59.926
85.705%
455
10.9
0.953
12.124V
5.064V
3.347V
5.083V
69.921
115.08V
4
4.885A
1.974A
1.968A
0.786A
79.785
87.689%
470
11.5
0.966
12.122V
5.063V
3.345V
5.079V
90.986
115.08V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
10.8 mV
5.6 mV
3.5 mV
4.5 mV
Pass
20% Load
14.1 mV
5.7 mV
3.7 mV
6.0 mV
Pass
30% Load
13.5 mV
5.9 mV
3.7 mV
6.0 mV
Pass
40% Load
13.3 mV
6.7 mV
4.2 mV
7.8 mV
Pass
50% Load
14.3 mV
6.6 mV
4.5 mV
9.0 mV
Pass
60% Load
14.7 mV
6.6 mV
4.3 mV
11.6 mV
Pass
70% Load
15.5 mV
6.8 mV
4.6 mV
18.1 mV
Pass
80% Load
15.0 mV
12.2 mV
6.0 mV
21.8 mV
Pass
90% Load
15.4 mV
22.4 mV
17.3 mV
23.7 mV
Pass
100% Load
14.8 mV
9.6 mV
6.6 mV
22.1 mV
Pass
110% Load
15.1 mV
9.1 mV
6.3 mV
17.0 mV
Pass
Crossload 1
14.4 mV
7.1 mV
4.8 mV
3.1 mV
Pass
Crossload 2
13.8 mV
8.5 mV
6.5 mV
17.0 mV
Pass
The results above are not used in the certification process