This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.043A
0.216
69.453%
0.031
5.104V
0.311
115.07V
2
0.088A
0.448
75.676%
0.059
5.102V
0.592
115.07V
3
0.543A
2.762
79.827%
0.267
5.092V
3.460
115.06V
4
1.003A
5.093
77.649%
0.374
5.080V
6.559
115.06V
5
1.502A
7.610
77.455%
0.430
5.066V
9.825
115.06V
6
2.502A
12.607
75.257%
0.483
5.039V
16.752
115.06V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.215
62.139%
0.011
5.103V
0.346
230.23V
2
0.088A
0.447
70.728%
0.019
5.103V
0.632
230.23V
3
0.543A
2.762
77.672%
0.102
5.091V
3.556
230.21V
4
1.002A
5.091
78.047%
0.172
5.080V
6.523
230.22V
5
1.502A
7.608
78.087%
0.232
5.066V
9.743
230.22V
6
2.502A
12.606
77.709%
0.314
5.039V
16.222
230.23V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.415A
1.975A
1.974A
0.986A
74.813
86.446%
480
9.6
38.28°C
0.967
12.054V
5.066V
3.341V
5.066V
86.543
45.50°C
115.12V
2
9.869A
2.960A
2.963A
1.186A
149.769
90.198%
480
9.6
38.66°C
0.986
12.047V
5.064V
3.339V
5.054V
166.044
47.34°C
115.12V
3
15.678A
3.455A
3.472A
1.385A
224.855
91.313%
480
9.6
39.15°C
0.989
12.042V
5.062V
3.338V
5.041V
246.246
49.57°C
115.12V
4
21.482A
3.952A
3.954A
1.590A
299.741
91.362%
480
9.6
39.43°C
0.991
12.036V
5.060V
3.336V
5.029V
328.079
52.54°C
115.12V
5
26.949A
4.948A
4.943A
1.794A
374.735
91.072%
480
9.6
40.42°C
0.990
12.031V
5.059V
3.335V
5.013V
411.469
56.58°C
115.12V
6
32.416A
5.934A
5.937A
1.999A
449.625
90.395%
505
8.9
41.43°C
0.990
12.026V
5.056V
3.334V
4.999V
497.401
60.97°C
115.12V
7
37.909A
6.930A
6.929A
2.204A
524.599
89.081%
1019
26.7
42.87°C
0.990
12.016V
5.053V
3.331V
4.985V
588.903
62.51°C
115.12V
8
43.401A
7.921A
7.928A
2.411A
599.505
88.343%
1276
32.0
43.23°C
0.991
12.007V
5.051V
3.329V
4.972V
678.607
63.22°C
115.11V
9
49.343A
8.424A
8.444A
2.415A
674.622
87.616%
1595
39.3
44.29°C
0.991
11.998V
5.048V
3.326V
4.967V
769.979
64.43°C
115.11V
10
55.228A
8.921A
8.931A
2.521A
749.436
86.869%
1902
43.5
45.81°C
0.992
11.991V
5.047V
3.324V
4.953V
862.721
66.48°C
115.10V
11
61.499A
8.925A
8.934A
2.541A
824.313
85.843%
2043
44.7
46.98°C
0.993
11.986V
5.044V
3.323V
4.912V
960.258
67.84°C
115.11V
CL1
0.099A
14.026A
14.004A
0.004A
118.859
84.019%
505
8.9
43.79°C
0.983
12.049V
5.053V
3.340V
5.069V
141.466
60.14°C
115.14V
CL2
62.450A
1.004A
1.002A
1.002A
762.822
87.196%
1956
44.3
46.15°C
0.992
12.000V
5.051V
3.329V
5.005V
874.834
66.04°C
115.10V
The results above are not used in the certification process
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.213A
0.493A
0.477A
0.196A
19.707
68.790%
480
9.6
0.826
12.049V
5.069V
3.343V
5.093V
28.648
115.11V
2
2.449A
0.980A
0.984A
0.391A
39.773
80.734%
480
9.6
0.924
12.058V
5.068V
3.341V
5.086V
49.264
115.11V
3
3.685A
1.474A
1.495A
0.591A
59.887
85.278%
480
9.6
0.957
12.055V
5.066V
3.341V
5.078V
70.226
115.11V
4
4.913A
1.974A
1.974A
0.786A
79.795
87.273%
480
9.6
0.969
12.053V
5.066V
3.340V
5.070V
91.432
115.11V
The results above are not used in the certification process
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
15.1 mV
6.4 mV
5.1 mV
12.2 mV
Pass
20% Load
20.9 mV
7.2 mV
6.5 mV
12.9 mV
Pass
30% Load
22.1 mV
7.8 mV
7.4 mV
13.8 mV
Pass
40% Load
22.8 mV
8.2 mV
8.6 mV
14.2 mV
Pass
50% Load
25.0 mV
14.2 mV
10.8 mV
14.9 mV
Pass
60% Load
27.8 mV
18.8 mV
11.6 mV
16.9 mV
Pass
70% Load
28.9 mV
12.3 mV
14.7 mV
28.6 mV
Pass
80% Load
30.3 mV
12.5 mV
14.2 mV
19.2 mV
Pass
90% Load
31.9 mV
16.1 mV
14.5 mV
19.2 mV
Pass
100% Load
33.2 mV
17.2 mV
16.9 mV
19.1 mV
Pass
110% Load
35.9 mV
28.5 mV
33.7 mV
27.4 mV
Pass
Crossload 1
32.2 mV
9.7 mV
9.5 mV
9.3 mV
Pass
Crossload 2
24.7 mV
12.5 mV
14.1 mV
19.1 mV
Pass
The results above are not used in the certification process
The results above are not used in the certification process
Bitfenix Formula Gold 750W (#2)
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case