This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.227W
52.858%
0.021
5.044V
0.432W
230.36V
2
0.09A
0.454W
63.813%
0.035
5.043V
0.712W
230.36V
3
0.55A
2.771W
79.149%
0.153
5.036V
3.502W
230.36V
4
1A
5.031W
79.75%
0.231
5.03V
6.309W
230.36V
5
1.5A
7.535W
80.013%
0.281
5.023V
9.416W
230.36V
6
3A
15.003W
79.427%
0.355
5.001V
18.887W
230.35V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
4.017A
1.963A
1.966A
0.996A
69.997
83.258%
1068
26.3
35.7°C
0.728
12.048V
5.094V
3.357V
5.022V
84.072
39.98°C
230.37V
20%
9.056A
2.952A
2.956A
1.197A
139.936
87.351%
1208
29.4
36.19°C
0.949
12.041V
5.082V
3.349V
5.012V
160.196
40.83°C
230.36V
30%
14.477A
3.446A
3.456A
1.4A
209.979
88.299%
1371
33
36.23°C
0.982
12.014V
5.079V
3.342V
5.002V
237.806
41.23°C
230.34V
40%
19.925A
3.941A
3.959A
1.603A
280.022
88.386%
1592
37.4
37.01°C
0.986
11.986V
5.076V
3.334V
4.992V
316.819
42.52°C
230.33V
50%
25.006A
4.939A
4.96A
1.807A
349.979
87.993%
1909
42.3
37.22°C
0.988
11.976V
5.063V
3.327V
4.982V
397.733
43.27°C
230.32V
60%
30.091A
5.943A
5.967A
2A
419.807
87.454%
2028
44
37.89°C
0.99
11.965V
5.049V
3.318V
4.972V
480.029
44.75°C
230.31V
70%
35.215A
6.954A
6.98A
2.218A
490.024
86.751%
2064
44.5
38.19°C
0.991
11.953V
5.034V
3.31V
4.961V
564.859
45.55°C
230.3V
80%
40.361A
7.971A
7.996A
2.323A
559.669
85.901%
2073
44.6
38.31°C
0.992
11.937V
5.02V
3.301V
4.952V
651.54
46.5°C
230.29V
90%
46.012A
8.474A
8.499A
2.428A
629.893
84.989%
2074
44.6
39.71°C
0.992
11.897V
5.016V
3.294V
4.943V
741.157
49.01°C
230.28V
100%
51.446A
8.983A
9.038A
3.046A
699.522
83.9%
2073
44.6
40.12°C
0.993
11.854V
5.01V
3.286V
4.925V
833.753
50.26°C
230.27V
110%
56.735A
10.013A
10.161A
3.051A
769.747
82.712%
2075
44.7
40.97°C
0.993
11.835V
4.993V
3.277V
4.917V
930.643
51.78°C
230.26V
CL1
1.922A
12.997A
12.515A
0.499A
131.413
79.073%
1827
40.6
37.52°C
0.952
12.493V
4.863V
3.332V
5.007V
166.191
42.96°C
230.35V
CL2
1.888A
20.285A
0.989A
0.498A
126.506
79.061%
1648
37.9
38.59°C
0.948
12.714V
4.767V
3.336V
5.019V
160.012
44.88°C
230.36V
CL3
1.994A
0.984A
18.256A
0.499A
92.503
76.045%
1285
31.4
39.55°C
0.869
12.034V
5.082V
3.341V
5.008V
121.638
46.65°C
230.36V
CL4
60.327A
0.958A
0.999A
0.503A
699.695
83.67%
2023
43.9
40.97°C
0.993
11.419V
5.219V
3.302V
4.976V
836.251
50.04°C
230.28V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.236A
0.488A
0.49A
0.198A
19.998
32.267%
1074
26.5
33.33°C
0.287
12.013V
5.123V
3.365V
5.041V
29.054
36.39°C
230.36V
40W
2.724A
0.683A
0.687A
0.298A
39.991
65.445%
985
24.2
33.61°C
0.555
12.000V
5.124V
3.363V
5.037V
51.84
37.01°C
230.32V
60W
4.212A
0.878A
0.883A
0.397A
59.99
83.334%
1044
25.5
34.29°C
0.67
11.994V
5.122V
3.36V
5.033V
71.988
37.86°C
230.33V
80W
5.696A
1.074A
1.081A
0.497A
79.936
85.528%
1030
25.2
34.63°C
0.767
11.990V
5.12V
3.358V
5.029V
93.458
38.35°C
230.33V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
15.22mV
7.06mV
9.21mV
6.93mV
Pass
20% Load
14.76mV
6.90mV
9.83mV
7.39mV
Pass
30% Load
14.45mV
6.24mV
9.93mV
7.80mV
Pass
40% Load
16.86mV
7.26mV
11.00mV
9.38mV
Pass
50% Load
17.52mV
6.96mV
11.82mV
10.20mV
Pass
60% Load
22.47mV
8.92mV
13.46mV
11.01mV
Pass
70% Load
27.48mV
10.97mV
14.43mV
15.85mV
Pass
80% Load
35.24mV
11.78mV
19.81mV
13.76mV
Pass
90% Load
45.71mV
15.83mV
21.65mV
15.75mV
Pass
100% Load
68.53mV
23.21mV
27.21mV
24.92mV
Pass
110% Load
73.83mV
24.22mV
27.89mV
27.97mV
Pass
Crossload1
20.89mV
28.94mV
29.81mV
11.18mV
Pass
Crossload2
17.47mV
28.38mV
19.14mV
10.55mV
Pass
Crossload3
19.66mV
9.31mV
24.87mV
8.36mV
Pass
Crossload4
68.03mV
22.80mV
19.65mV
20.79mV
Pass
The results above are not used in the certification process
Micronics Coolmax Focus II ETA Bronze 700W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted