This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.227W
52.488%
0.021
5.043V
0.432W
230.27V
2
0.09A
0.454W
63.444%
0.035
5.042V
0.716W
230.27V
3
0.55A
2.769W
79.219%
0.15
5.036V
3.495W
230.28V
4
1A
5.029W
79.736%
0.227
5.029V
6.307W
230.27V
5
1.5A
7.533W
80.269%
0.279
5.022V
9.385W
230.27V
6
2.999A
14.998W
79.865%
0.353
5.001V
18.779W
230.27V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
3.168A
1.953A
1.958A
0.995A
59.986
82.182%
853
26.8
35.81°C
0.695
12.116V
5.119V
3.371V
5.024V
72.992
40.21°C
230.29V
20%
7.350A
2.938A
2.944A
1.196A
119.904
86.815%
853
26.8
36.29°C
0.918
12.112V
5.105V
3.362V
5.014V
138.115
41.26°C
230.29V
30%
11.905A
3.429A
3.443A
1.398A
179.935
88.048%
852
26.8
36.52°C
0.976
12.086V
5.103V
3.354V
5.006V
204.359
41.77°C
230.29V
40%
16.493A
3.923A
3.944A
1.6A
239.968
88.265%
851
26.7
36.91°C
0.985
12.051V
5.098V
3.347V
4.998V
271.87
42.71°C
230.29V
50%
20.715A
4.92A
4.943A
1.804A
299.913
87.972%
851
26.7
37.54°C
0.987
12.040V
5.082V
3.338V
4.989V
340.918
43.67°C
230.28V
60%
24.938A
5.922A
5.948A
2A
359.894
87.452%
1089
34.1
37.78°C
0.989
12.035V
5.066V
3.329V
4.98V
411.535
44.45°C
230.29V
70%
29.112A
6.932A
6.958A
2.212A
419.289
86.685%
1469
42.2
38.09°C
0.99
12.029V
5.049V
3.32V
4.97V
483.693
45.29°C
230.28V
80%
33.392A
7.951A
7.97A
2.317A
479.309
85.88%
1720
46.0
38.35°C
0.991
12.021V
5.032V
3.311V
4.961V
558.117
46.46°C
230.28V
90%
38.082A
8.452A
8.476A
2.422A
539.096
85.142%
1754
46.4
38.61°C
0.992
11.991V
5.027V
3.302V
4.953V
633.17
47.65°C
230.28V
100%
42.627A
8.969A
9.017A
3.038A
599.133
84.253%
1826
47.4
40.41°C
0.992
11.951V
5.017V
3.293V
4.936V
711.112
49.87°C
230.3V
110%
47.123A
10.009A
10.141A
3.043A
659.814
82.857%
1830
47.4
41.03°C
0.992
11.916V
4.995V
3.282V
4.927V
796.329
51.82°C
230.31V
CL1
1.908A
12.961A
12.481A
0.499A
131.386
79.044%
904
28.7
37.3°C
0.953
12.582V
4.876V
3.34V
5.01V
166.218
43.71°C
230.32V
CL2
1.877A
20.198A
0.986A
0.498A
126.498
79.062%
969
30.6
38.53°C
0.948
12.787V
4.788V
3.346V
5.015V
159.998
45.66°C
230.33V
CL3
1.984A
0.98A
18.2A
0.498A
92.485
75.387%
853
26.8
39.22°C
0.875
12.096V
5.105V
3.351V
5.015V
122.68
48.07°C
230.33V
CL4
51.197A
0.956A
0.997A
0.502A
599.477
84.197%
1777
46.7
40.83°C
0.992
11.498V
5.232V
3.31V
4.984V
712.004
50.71°C
230.32V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.229A
0.485A
0.488A
0.198A
19.984
69.166%
838
26.2
33.53°C
0.414
12.068V
5.152V
3.378V
5.04V
28.427
36.63°C
230.31V
40W
2.710A
0.679A
0.684A
0.298A
39.985
80.127%
838
26.2
33.77°C
0.559
12.057V
5.152V
3.376V
5.037V
49.92
37.11°C
230.31V
60W
4.192A
0.873A
0.88A
0.397A
59.985
83.648%
839
26.3
34.09°C
0.686
12.051V
5.15V
3.373V
5.034V
71.711
37.64°C
230.31V
80W
5.670A
1.068A
1.076A
0.497A
79.921
85.709%
842
26.4
34.77°C
0.78
12.044V
5.148V
3.371V
5.03V
93.248
38.5°C
230.3V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
14.03mV
7.32mV
8.55mV
11.03mV
Pass
20% Load
14.08mV
8.18mV
8.80mV
8.20mV
Pass
30% Load
13.97mV
8.28mV
8.64mV
9.16mV
Pass
40% Load
33.69mV
13.82mV
8.70mV
9.36mV
Pass
50% Load
36.48mV
14.84mV
9.10mV
13.21mV
Pass
60% Load
36.99mV
16.87mV
10.11mV
14.77mV
Pass
70% Load
43.17mV
19.06mV
10.52mV
17.36mV
Pass
80% Load
54.66mV
24.45mV
15.72mV
20.95mV
Pass
90% Load
64.33mV
28.11mV
16.63mV
22.92mV
Pass
100% Load
98.83mV
41.70mV
18.71mV
25.37mV
Pass
110% Load
111.50mV
45.91mV
20.25mV
28.49mV
Pass
Crossload1
18.57mV
20.60mV
23.32mV
13.88mV
Pass
Crossload2
16.40mV
24.29mV
21.43mV
13.86mV
Pass
Crossload3
16.45mV
9.35mV
20.58mV
9.97mV
Pass
Crossload4
97.46mV
39.43mV
19.15mV
22.26mV
Pass
The results above are not used in the certification process
Micronics Coolmax Focus II ETA Bronze 600W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted