This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
230V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
230V
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.235W
10.377%
0.056
5.23V
2.265W
230.35V
2
0.09A
0.468W
18.165%
0.063
5.203V
2.577W
230.35V
3
0.55A
2.818W
50.762%
0.128
5.125V
5.551W
230.33V
4
1A
5.087W
59.881%
0.182
5.087V
8.495W
230.33V
5
1.5A
7.58W
64.359%
0.231
5.053V
11.778W
230.34V
6
3.5A
17.23W
69.475%
0.344
4.924V
24.8W
230.34V
Supplementary Tests (For Reference)
230V
Test
Main Rail
Standby Rail
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
10%
2.756A
0.982A
38.408
68.681%
34.56°C
0.683
12.123V
5.093V
55.922
38.73°C
230.24V
20%
5.845A
1.183A
76.819
78.986%
34.57°C
0.818
12.117V
5.07V
97.256
39.01°C
230.24V
30%
8.939A
1.387A
115.188
82.852%
35.2°C
0.892
12.102V
5.048V
139.029
39.89°C
230.24V
40%
12.045A
1.592A
153.641
84.614%
35.57°C
0.928
12.091V
5.026V
181.579
40.51°C
230.25V
50%
15.154A
1.798A
192.023
85.57%
35.96°C
0.947
12.077V
5.006V
224.403
41.52°C
230.25V
60%
18.281A
2A
230.447
86.006%
36.42°C
0.96
12.060V
4.985V
267.943
42.72°C
230.25V
70%
21.412A
2.217A
268.858
86.216%
36.9°C
0.965
12.043V
4.964V
311.842
44.24°C
230.25V
80%
24.596A
2.324A
307.298
86.202%
37.43°C
0.968
12.026V
4.95V
356.486
45.85°C
230.25V
90%
27.808A
2.432A
345.841
85.975%
38.57°C
0.973
12.005V
4.935V
402.256
47.58°C
230.25V
100%
30.977A
2.539A
383.913
85.572%
39.01°C
0.975
11.990V
4.924V
448.641
49.44°C
230.25V
110%
34.224A
2.541A
422.287
85.035%
40.45°C
0.975
11.974V
4.919V
496.605
51.71°C
230.24V
The results above are not used in the certification process
230V
Test
Main Rail
Standby Rail
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
20W
1.566A
0.193A
20.001
56.274%
31.36°C
0.569
12.128V
5.175V
35.542
34.4°C
230.22V
40W
3.176A
0.291A
40.007
71.01%
32.65°C
0.686
12.126V
5.156V
56.339
35.83°C
230.22V
60W
4.785A
0.389A
60.005
77.005%
33.55°C
0.763
12.123V
5.141V
77.924
36.98°C
230.22V
80W
6.392A
0.488A
79.95
80.372%
33.62°C
0.826
12.116V
5.127V
99.476
37.31°C
230.23V
The results above are not used in the certification process
230V
Test
12V
12VSB
Pass/Fail
10% Load
8.61mV
7.84mV
Pass
20% Load
9.32mV
7.54mV
Pass
30% Load
10.68mV
7.79mV
Pass
40% Load
12.30mV
7.49mV
Pass
50% Load
14.38mV
8.04mV
Pass
60% Load
18.84mV
9.46mV
Pass
70% Load
22.03mV
9.87mV
Pass
80% Load
24.35mV
10.42mV
Pass
90% Load
28.45mV
11.84mV
Pass
100% Load
34.85mV
13.70mV
Pass
110% Load
39.13mV
14.07mV
Pass
The results above are not used in the certification process