This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
转换效率图表
230V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
230V
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 230V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.235W
14.988%
0.049
5.231V
1.568W
230.32V
2
0.09A
0.47W
24.985%
0.058
5.224V
1.881W
230.34V
3
0.55A
2.811W
57.301%
0.14
5.112V
4.905W
230.29V
4
1A
5.055W
64.794%
0.201
5.055V
7.801W
230.28V
5
1.5A
7.531W
68.111%
0.253
5.021V
11.056W
230.27V
6
3.499A
17.1W
70.898%
0.361
4.887V
24.119W
230.26V
Supplementary Tests (For Reference)
10-110%负载测试 230V
测试
Main 组
待机 组
DC/AC (瓦)
效率
温度(输入/输出)
PF/AC 电压
10%
6.220A
0.984A
79.935
81.43%
40.18°C
0.816
12.048V
5.081V
98.165
44.97°C
230.31V
20%
12.798A
1.187A
159.966
87.69%
40.67°C
0.865
12.030V
5.053V
182.421
45.8°C
230.3V
30%
19.380A
1.392A
239.928
89.374%
40.77°C
0.91
12.019V
5.027V
268.453
46.38°C
230.28V
40%
25.987A
1.6A
319.971
89.79%
41.3°C
0.943
12.005V
5V
356.357
47.31°C
230.28V
50%
32.541A
1.809A
399.145
89.607%
42.55°C
0.958
11.989V
4.973V
445.44
49.24°C
230.27V
60%
39.194A
2A
479.257
89.134%
43.13°C
0.969
11.975V
4.948V
537.682
50.27°C
230.27V
70%
45.866A
2.234A
559.586
88.465%
43.43°C
0.972
11.961V
4.92V
632.555
51.18°C
230.27V
80%
52.558A
2.345A
639.333
87.624%
43.71°C
0.975
11.945V
4.901V
729.633
51.97°C
230.27V
90%
59.334A
2.457A
719.867
86.567%
44.71°C
0.976
11.930V
4.882V
831.576
53.8°C
230.27V
100%
65.662A
3.665A
799.782
85.336%
45.3°C
0.977
11.914V
4.774V
937.219
55.1°C
230.27V
110%
72.476A
3.675A
879.778
83.944%
46.07°C
0.976
11.898V
4.76V
1048.063
56.77°C
230.27V
The results above are not used in the certification process
20-80瓦负载测试 230V
测试
Main 组
待机 组
DC/AC (瓦)
效率
温度(输入/输出)
PF/AC 电压
20W
1.575A
0.193A
19.991
56.488%
36.36°C
0.6
12.056V
5.181V
35.389
39.54°C
230.32V
40W
3.194A
0.291A
39.995
71.497%
37.18°C
0.718
12.053V
5.161V
55.94
40.62°C
230.32V
60W
4.812A
0.389A
59.992
78.33%
37.78°C
0.783
12.051V
5.145V
76.589
41.64°C
230.33V
80W
6.426A
0.487A
79.932
81.909%
38.35°C
0.814
12.049V
5.132V
97.587
42.61°C
230.33V
The results above are not used in the certification process
纹波测量 230V
Test
Main Rail
Standby Rail
Pass/Fail
10% Load
10.9 mV
8.8 mV
Pass
20% Load
12.2 mV
9.1 mV
Pass
30% Load
14.0 mV
8.2 mV
Pass
40% Load
17.2 mV
9.0 mV
Pass
50% Load
23.3 mV
9.1 mV
Pass
60% Load
28.0 mV
10.8 mV
Pass
70% Load
34.6 mV
10.4 mV
Pass
80% Load
39.6 mV
11.3 mV
Pass
90% Load
46.4 mV
12.1 mV
Pass
100% Load
54.9 mV
17.1 mV
Pass
110% Load
60.4 mV
16.2 mV
Pass
The results above are not used in the certification process