This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
转换效率图表
230V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
230V
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 230V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.235W
14.46%
0.04
5.219V
1.625W
230.35V
2
0.09A
0.468W
24.182%
0.047
5.198V
1.935W
230.36V
3
0.55A
2.818W
55.969%
0.118
5.124V
5.035W
230.34V
4
1A
5.083W
63.53%
0.178
5.083V
8.001W
230.35V
5
1.5A
7.566W
67.285%
0.233
5.044V
11.245W
230.35V
6
3.5A
17.094W
69.717%
0.369
4.885V
24.519W
230.35V
Supplementary Tests (For Reference)
10-110%负载测试 230V
测试
Main 组
待机 组
DC/AC (瓦)
效率
温度(输入/输出)
PF/AC 电压
10%
3.670A
0.984A
49.19
75.46%
37.22°C
0.73
12.039V
5.081V
65.187
43.19°C
230.24V
20%
7.684A
1.186A
98.37
83.819%
37.58°C
0.824
12.022V
5.057V
117.359
44.14°C
230.24V
30%
11.702A
1.391A
147.533
86.73%
38.66°C
0.886
12.008V
5.033V
170.106
45.64°C
230.25V
40%
15.734A
1.596A
196.787
87.86%
39.24°C
0.922
12.000V
5.013V
223.978
46.69°C
230.26V
50%
19.758A
1.804A
245.94
88.469%
39.96°C
0.947
11.992V
4.988V
277.996
47.86°C
230.25V
60%
23.801A
2A
295.117
88.492%
40.57°C
0.958
11.982V
4.966V
333.496
49.28°C
230.25V
70%
27.783A
2.224A
343.6
88.232%
41.19°C
0.969
11.971V
4.945V
389.429
50.42°C
230.27V
80%
31.891A
2.33A
392.951
87.867%
42.06°C
0.974
11.961V
4.933V
447.214
52.19°C
230.27V
90%
36.004A
2.438A
442.268
87.32%
42.85°C
0.976
11.951V
4.92V
506.489
53.53°C
230.27V
100%
39.726A
3.625A
491.78
86.473%
43.43°C
0.978
11.939V
4.826V
568.71
54.61°C
230.27V
110%
43.856A
3.631A
540.607
85.632%
44.5°C
0.98
11.928V
4.819V
631.315
56.27°C
230.27V
The results above are not used in the certification process
20-80瓦负载测试 230V
测试
Main 组
待机 组
DC/AC (瓦)
效率
温度(输入/输出)
PF/AC 电压
20W
1.576A
0.193A
19.987
59.556%
33.28°C
0.54
12.047V
5.17V
33.56
36.38°C
230.23V
40W
3.196A
0.291A
39.992
73.417%
34.13°C
0.685
12.042V
5.152V
54.473
38.08°C
230.23V
60W
4.818A
0.389A
59.99
79.187%
35.45°C
0.76
12.036V
5.138V
75.757
39.94°C
230.23V
80W
6.436A
0.488A
79.913
82.42%
36.38°C
0.8
12.029V
5.125V
96.959
41.29°C
230.23V
The results above are not used in the certification process
纹波测量 230V
Test
12V
12VSB
Pass/Fail
10% Load
12.71mV
8.35mV
Pass
20% Load
14.58mV
9.01mV
Pass
30% Load
16.81mV
8.60mV
Pass
40% Load
19.75mV
11.74mV
Pass
50% Load
23.09mV
10.02mV
Pass
60% Load
27.44mV
10.98mV
Pass
70% Load
33.01mV
16.95mV
Pass
80% Load
37.62mV
19.99mV
Pass
90% Load
43.74mV
22.42mV
Pass
100% Load
52.14mV
27.91mV
Pass
110% Load
59.56mV
31.08mV
Pass
The results above are not used in the certification process