This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
转换效率图表
230V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
230V
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 230V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.235W
6.683%
0.086
5.22V
3.516W
230.27V
2
0.09A
0.468W
12.348%
0.092
5.201V
3.79W
230.27V
3
0.55A
2.822W
43.167%
0.143
5.133V
6.538W
230.28V
4
1A
5.097W
54.852%
0.182
5.098V
9.293W
230.28V
5
1.5A
7.608W
61.806%
0.213
5.073V
12.31W
230.28V
6
3.499A
17.254W
70.739%
0.276
4.931V
24.392W
230.28V
Supplementary Tests (For Reference)
10-110%负载测试 230V
测试
Main 组
待机 组
DC/AC (瓦)
效率
温度(输入/输出)
PF/AC 电压
10%
4.544A
0.986A
59.992
80.266%
38.58°C
0.817
12.101V
5.071V
74.742
42.13°C
230.27V
20%
9.430A
1.182A
119.976
87.568%
39.3°C
0.897
12.087V
5.073V
137.009
43.21°C
230.27V
30%
14.325A
1.385A
179.937
90.105%
40.24°C
0.933
12.072V
5.054V
199.697
44.42°C
230.27V
40%
19.236A
1.589A
239.975
91.276%
40.69°C
0.947
12.059V
5.034V
262.91
45.25°C
230.27V
50%
24.153A
1.794A
299.94
91.828%
41.29°C
0.958
12.045V
5.015V
326.631
46.31°C
230.29V
60%
29.053A
2A
359.433
92.089%
42.04°C
0.967
12.028V
4.996V
390.312
47.64°C
230.29V
70%
34.007A
2.208A
419.583
92.219%
43.05°C
0.972
12.015V
4.978V
454.986
49.27°C
230.3V
80%
38.999A
2.314A
479.332
92.194%
43.65°C
0.975
11.996V
4.968V
519.919
50.47°C
230.29V
90%
44.073A
2.419A
539.871
92.007%
44.65°C
0.978
11.977V
4.958V
586.774
52.33°C
230.29V
100%
48.712A
3.592A
599.78
91.587%
45.95°C
0.98
11.953V
4.871V
654.875
54.54°C
230.29V
110%
53.860A
3.597A
659.83
91.307%
46.76°C
0.983
11.926V
4.864V
722.652
56.2°C
230.29V
The results above are not used in the certification process
20-80瓦负载测试 230V
测试
Main 组
待机 组
DC/AC (瓦)
效率
温度(输入/输出)
PF/AC 电压
10W
1.568A
0.194A
19.988
61.054%
35.67°C
0.608
12.110V
5.167V
32.739
36.87°C
230.27V
20W
3.180A
0.291A
39.993
74.849%
36.26°C
0.747
12.104V
5.149V
53.432
37.69°C
230.27V
30W
4.793A
0.39A
59.992
80.936%
36.6°C
0.816
12.100V
5.131V
74.122
38.52°C
230.27V
40W
6.400A
0.488A
79.916
84.212%
37.23°C
0.854
12.095V
5.122V
94.898
39.52°C
230.27V
The results above are not used in the certification process
纹波测量 230V
Test
Main Rail
Standby Rail
Pass/Fail
10% Load
32.9 mV
18.5 mV
Pass
20% Load
30.4 mV
29.1 mV
Pass
30% Load
32.6 mV
31.0 mV
Pass
40% Load
39.6 mV
31.0 mV
Pass
50% Load
46.5 mV
33.0 mV
Pass
60% Load
51.9 mV
36.7 mV
Pass
70% Load
71.4 mV
39.0 mV
Pass
80% Load
82.2 mV
42.0 mV
Pass
90% Load
96.3 mV
45.2 mV
Pass
100% Load
145.0 mV
45.7 mV
Fail
110% Load
198.6 mV
47.1 mV
Fail
The results above are not used in the certification process