This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
转换效率图表
230V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
230V
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 230V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.234W
6.547%
0.086
5.202V
3.574W
230.28V
2
0.09A
0.466W
12.108%
0.091
5.181V
3.849W
230.28V
3
0.55A
2.813W
42.881%
0.142
5.116V
6.56W
230.28V
4
1A
5.081W
54.308%
0.181
5.082V
9.356W
230.28V
5
1.5A
7.584W
61.023%
0.212
5.057V
12.429W
230.28V
6
3.499A
17.213W
70.038%
0.276
4.92V
24.577W
230.29V
Supplementary Tests (For Reference)
10-110%负载测试 230V
测试
Main 组
待机 组
DC/AC (瓦)
效率
温度(输入/输出)
PF/AC 电压
10%
7.784A
0.988A
99.543
85.699%
40.85°C
0.84
12.146V
5.058V
116.154
39.17°C
230.33V
20%
15.942A
1.191A
199.192
90.331%
41.27°C
0.903
12.119V
5.035V
220.512
43.75°C
230.33V
30%
24.125A
1.391A
298.761
91.755%
41.86°C
0.93
12.093V
5.033V
325.608
44.92°C
230.34V
40%
32.326A
1.597A
398.264
92.082%
42.16°C
0.949
12.073V
5.009V
432.512
45.19°C
230.33V
50%
40.614A
1.805A
497.699
91.942%
42.76°C
0.958
12.033V
4.987V
541.317
47.82°C
230.33V
60%
49.026A
2A
597.075
91.597%
43.16°C
0.966
11.976V
4.964V
651.849
48.57°C
230.34V
70%
57.569A
2.226A
696.607
91.067%
43.77°C
0.973
11.909V
4.94V
764.936
49.38°C
230.34V
80%
66.313A
2.334A
796.396
90.429%
44.39°C
0.978
11.836V
4.926V
880.692
51.62°C
230.34V
90%
75.188A
2.442A
896.166
89.639%
44.98°C
0.982
11.760V
4.912V
999.755
53.44°C
230.34V
100%
83.777A
3.631A
996.199
88.787%
45.93°C
0.985
11.682V
4.819V
1122.007
53.54°C
230.34V
The results above are not used in the certification process
20-80瓦负载测试 230V
测试
Main 组
待机 组
DC/AC (瓦)
效率
温度(输入/输出)
PF/AC 电压
10W
1.561A
0.194A
19.995
60.403%
37.23°C
0.548
12.166V
5.152V
33.102
38.77°C
230.32V
20W
3.166A
0.292A
39.997
74.273%
38.44°C
0.692
12.159V
5.135V
53.851
40.41°C
230.32V
30W
4.771A
0.391A
59.994
80.512%
38.95°C
0.772
12.155V
5.117V
74.515
41.61°C
230.32V
40W
6.372A
0.489A
79.926
83.969%
39.38°C
0.813
12.151V
5.11V
95.185
42.42°C
230.33V
The results above are not used in the certification process
纹波测量 230V
Test
Main Rail
Standby Rail
Pass/Fail
10% Load
25.9 mV
16.1 mV
Pass
20% Load
36.8 mV
16.7 mV
Pass
30% Load
53.6 mV
36.4 mV
Pass
40% Load
82.6 mV
38.1 mV
Pass
50% Load
159.6 mV
40.0 mV
Fail
60% Load
200.0 mV
42.9 mV
Fail
70% Load
200.0 mV
48.8 mV
Fail
80% Load
200.0 mV
51.9 mV
Fail
90% Load
200.0 mV
53.1 mV
Fail
100% Load
498.6 mV
67.1 mV
Fail
The results above are not used in the certification process