ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: ✓
ErP Lot 3/6 2014, CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
Efficiency Rating
SILVER
Noise Rating
Standard+
Average Efficiency (>1450 load combinations)
86.019%
Average Noise Output (>1450 Load Combinations)
37.07dBA
Average PF (>1450 Load Combinations)
0.989
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0915W
12V Ripple (Full Load)
21.15mV
5V Ripple (Full Load)
12.25mV
3.3V Ripple (Full Load)
13.22mV
5VSB Ripple (Full Load)
16.61mV
12V Load Regulation
0.26%
5V Load Regulation
0.06%
3.3V Load Regulation
0.47%
5VSB Load Regulation
2.72%
Inrush Current
98.637A
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
15
AC Loss to PWR_OK Hold Up Time (ms)
12.4
PWR_OK Inactive to DC Loss Delay (ms)
2.6
Vampire Power
Tables 115V
Graphs 115V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228
68.468%
0.029
5.052V
0.333
115.39V
2
0.090A
0.455
73.034%
0.053
5.051V
0.623
115.39V
3
0.550A
2.774
77.747%
0.236
5.042V
3.568
115.38V
4
1.000A
5.034
78.107%
0.320
5.034V
6.445
115.37V
5
1.500A
7.537
77.517%
0.367
5.024V
9.723
115.38V
6
2.500A
12.511
76.157%
0.413
5.004V
16.428
115.36V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.336A
1.982A
1.959A
0.996A
49.688
79.360%
1353
32.6
38.04°C
0.957
12.017V
5.051V
3.371V
5.022V
62.611
41.17°C
115.31V
2
5.733A
2.970A
2.941A
1.198A
99.796
84.876%
1509
38.1
38.90°C
0.984
12.015V
5.052V
3.369V
5.009V
117.579
42.08°C
115.24V
3
9.466A
3.466A
3.415A
1.401A
149.721
86.727%
1579
37.7
39.05°C
0.991
12.013V
5.051V
3.367V
4.997V
172.635
42.49°C
115.17V
4
13.199A
3.961A
3.924A
1.605A
199.744
87.560%
1737
39.3
39.48°C
0.995
12.011V
5.051V
3.365V
4.985V
228.122
43.09°C
115.20V
5
16.601A
4.953A
4.906A
1.811A
249.861
87.273%
1770
39.9
39.82°C
0.992
12.008V
5.050V
3.363V
4.972V
286.299
44.24°C
115.12V
6
20.002A
5.942A
5.891A
2.017A
299.952
86.804%
1770
39.9
40.26°C
0.991
12.006V
5.050V
3.361V
4.959V
345.549
45.97°C
115.05V
7
23.410A
6.933A
6.876A
2.225A
350.084
86.268%
1776
39.9
41.18°C
0.992
12.002V
5.050V
3.360V
4.945V
405.811
48.31°C
114.97V
8
26.821A
7.923A
7.862A
2.435A
400.190
85.610%
1776
39.9
42.52°C
0.993
11.997V
5.050V
3.358V
4.931V
467.455
50.75°C
114.99V
9
30.637A
8.418A
8.343A
2.439A
449.916
84.860%
1776
39.9
44.16°C
0.993
11.992V
5.051V
3.356V
4.920V
530.186
53.50°C
114.92V
10
34.455A
8.912A
8.856A
2.547A
500.238
83.925%
1776
39.9
45.64°C
0.994
11.987V
5.051V
3.355V
4.908V
596.056
56.59°C
114.83V
11
38.607A
8.911A
8.858A
2.552A
549.861
82.875%
1776
39.9
46.42°C
0.994
11.983V
5.052V
3.354V
4.900V
663.482
60.89°C
114.74V
CL1
0.742A
13.002A
13.002A
0.000A
118.436
83.118%
1770
39.9
44.69°C
0.987
12.004V
5.055V
3.369V
4.998V
142.491
51.92°C
115.21V
CL2
41.682A
1.002A
1.000A
1.000A
513.017
84.242%
1776
39.9
46.27°C
0.994
11.987V
5.050V
3.356V
4.959V
608.979
57.18°C
114.82V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.201A
0.495A
0.476A
0.198A
19.535
66.527%
1015
25.3
0.860
12.019V
5.047V
3.369V
5.045V
29.364
115.35V
2
2.464A
0.991A
0.980A
0.397A
39.918
77.399%
1133
28.3
0.939
12.018V
5.049V
3.370V
5.037V
51.574
115.33V
3
3.666A
1.485A
1.454A
0.597A
59.461
81.581%
1275
32.0
0.966
12.018V
5.051V
3.370V
5.030V
72.886
115.30V
4
4.931A
1.980A
1.958A
0.797A
79.850
84.219%
1393
34.9
0.976
12.016V
5.051V
3.369V
5.022V
94.812
115.27V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
4.8 mV
7.3 mV
6.9 mV
7.1 mV
Pass
20% Load
6.4 mV
7.4 mV
7.7 mV
7.7 mV
Pass
30% Load
8.5 mV
8.2 mV
8.2 mV
8.9 mV
Pass
40% Load
9.8 mV
8.8 mV
8.9 mV
9.8 mV
Pass
50% Load
11.3 mV
10.2 mV
9.4 mV
10.9 mV
Pass
60% Load
12.4 mV
10.7 mV
10.2 mV
11.9 mV
Pass
70% Load
14.8 mV
11.4 mV
11.0 mV
13.2 mV
Pass
80% Load
18.4 mV
11.5 mV
12.5 mV
14.1 mV
Pass
90% Load
21.2 mV
10.8 mV
11.7 mV
14.4 mV
Pass
100% Load
21.2 mV
12.3 mV
13.2 mV
16.6 mV
Pass
110% Load
22.5 mV
13.4 mV
14.1 mV
17.1 mV
Pass
Crossload 1
8.5 mV
9.6 mV
11.0 mV
17.6 mV
Pass
Crossload 2
22.3 mV
12.1 mV
11.1 mV
13.0 mV
Pass
The results above are not used in the certification process
EVGA 500 BQ
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted