ErP Lot 6 2010: Partially
ErP Lot 6 2013: Partially
ErP Lot 3 2014 & CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary
Efficiency Rating
Noise Rating
Standard+
Average Efficiency (>1450 load combinations)
82.868%
Average Noise Output (>1450 Load Combinations)
39.13dBA
Average PF (>1450 Load Combinations)
0.983
Efficiency With 10W (≤500W) or 2% (>500W) Load
65.761%
Standby Power Consumption
0.3455W
12V Ripple (Full Load)
61.01mV
5V Ripple (Full Load)
24.34mV
3.3V Ripple (Full Load)
25.23mV
5VSB Ripple (Full Load)
21.86mV
12V Load Regulation
1.73%
5V Load Regulation
2.97%
3.3V Load Regulation
3.43%
5VSB Load Regulation
3.87%
Inrush Current
76.170A
Efficiency Rating
Noise Rating
Standard+
Average Efficiency (>1450 load combinations)
85.223%
Average Noise Output (>1450 Load Combinations)
38.66dBA
Average PF (>1450 Load Combinations)
0.947
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.5488W
12V Ripple (Full Load)
79.16mV
5V Ripple (Full Load)
33.05mV
3.3V Ripple (Full Load)
24.78mV
5VSB Ripple (Full Load)
22.17mV
12V Load Regulation
1.72%
5V Load Regulation
2.93%
3.3V Load Regulation
3.47%
5VSB Load Regulation
3.87%
Inrush Current
85.770A
Hold-Up Time & Power Ok Signal
11.30ms
AC Loss to PWR_OK Hold Up Time
9.40ms
PWR_OK Inactive to DC Loss Delay
1.90ms
PSU Timings: T1 (20% / 100%)
54.0ms
52.0ms
PSU Timings: T3 (20% / 100%)
299.0ms
297.0ms
OPP (26.50°C / 41.26°C)
116.84%
114.15%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
11.3
AC Loss to PWR_OK Hold Up Time (ms)
9.4
PWR_OK Inactive to DC Loss Delay (ms)
1.9
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
33.549%
0.072
5.108V
0.686W
115.18V
2
0.09A
0.46W
46.778%
0.101
5.106V
0.983W
115.18V
3
0.55A
2.799W
68.865%
0.291
5.09V
4.065W
115.17V
4
1A
5.074W
70.677%
0.366
5.074V
7.179W
115.17V
5
1.5A
7.585W
70.319%
0.407
5.056V
10.786W
115.18V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
26.403%
0.029
5.108V
0.871W
230.31V
2
0.09A
0.46W
38.429%
0.04
5.106V
1.197W
230.31V
3
0.55A
2.799W
63.96%
0.135
5.09V
4.376W
230.32V
4
1A
5.074W
68.547%
0.202
5.075V
7.402W
230.32V
5
1.5A
7.586W
69.625%
0.257
5.057V
10.895W
230.33V
6
2.499A
12.552W
69.904%
0.321
5.022V
17.955W
230.33V
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
3.488A
1.978A
1.981A
0.987A
64.992
81.328%
1000
29.8
35.26°C
0.94
12.439V
5.056V
3.332V
5.064V
79.913
38.47°C
115.14V
20%
7.974A
2.975A
2.981A
1.189A
129.916
84.867%
1040
30.7
35.76°C
0.962
12.419V
5.042V
3.321V
5.046V
153.082
39.58°C
115.14V
30%
12.830A
3.476A
3.488A
1.392A
194.907
85.73%
1175
33.9
36.23°C
0.973
12.381V
5.036V
3.311V
5.029V
227.349
40.57°C
115.14V
40%
17.721A
3.977A
4A
1.596A
259.983
85.682%
1465
39.7
36.49°C
0.981
12.346V
5.03V
3.3V
5.012V
303.428
41.59°C
115.14V
50%
22.247A
4.989A
5.017A
1.802A
324.966
85.179%
1520
40.9
37.17°C
0.987
12.337V
5.011V
3.289V
4.994V
381.509
42.68°C
115.14V
60%
26.727A
6.009A
6.041A
2A
389.232
84.371%
1651
42.8
37.53°C
0.99
12.328V
4.993V
3.278V
4.976V
461.336
44.01°C
115.14V
70%
31.301A
7.036A
7.074A
2.218A
454.618
83.451%
1779
44.3
38.89°C
0.991
12.316V
4.975V
3.266V
4.956V
544.775
45.89°C
115.13V
80%
35.892A
8.002A
8.112A
2.327A
519.118
82.307%
1962
46.8
39.99°C
0.992
12.302V
4.959V
3.253V
4.94V
630.713
47.63°C
115.13V
90%
40.955A
8.584A
8.633A
2.436A
584.851
81.165%
2032
47.6
40.51°C
0.993
12.266V
4.951V
3.243V
4.925V
720.572
48.89°C
115.13V
100%
45.991A
9.104A
9.187A
2.545A
649.559
79.864%
2085
48.1
40.89°C
0.993
12.228V
4.943V
3.232V
4.91V
813.338
50.15°C
115.14V
110%
50.700A
10.154A
10.342A
2.552A
715.002
77.918%
2141
48.7
41.35°C
0.991
12.213V
4.924V
3.219V
4.896V
917.64
51.28°C
115.17V
CL1
3.726A
13.073A
12.658A
0.495A
155.395
77.978%
1744
43.9
37.43°C
0.968
12.883V
4.835V
3.294V
5.045V
199.281
42.5°C
115.16V
CL2
3.659A
20.385A
1A
0.495A
150.506
78.583%
1530
40.9
38.27°C
0.967
13.117V
4.744V
3.3V
5.053V
191.526
44.72°C
115.16V
CL3
3.876A
0.992A
18.443A
0.494A
116.492
74.379%
1454
39.6
39.1°C
0.962
12.385V
5.044V
3.307V
5.054V
156.619
46.18°C
115.16V
CL4
54.535A
0.972A
1.014A
0.5A
649.942
80.007%
1761
44.2
40.71°C
0.993
11.720V
5.145V
3.254V
4.998V
812.361
49.33°C
115.14V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
3.489A
1.978A
1.981A
0.987A
64.993
82.562%
999
29.7
34.34°C
0.825
12.437V
5.056V
3.332V
5.063V
78.72
37.88°C
230.32V
20%
7.972A
2.976A
2.981A
1.189A
129.924
86.535%
1008
30.1
34.76°C
0.898
12.422V
5.041V
3.321V
5.046V
150.14
38.72°C
230.32V
30%
12.833A
3.476A
3.489A
1.392A
194.921
87.407%
1241
35.7
35.09°C
0.927
12.380V
5.035V
3.31V
5.029V
223.003
39.57°C
230.32V
40%
17.723A
3.977A
4A
1.596A
260.001
87.595%
1441
39.3
35.88°C
0.941
12.345V
5.029V
3.3V
5.011V
296.822
41.44°C
230.32V
50%
22.251A
4.99A
5.017A
1.802A
324.986
87.252%
1559
41
36.43°C
0.953
12.336V
5.011V
3.289V
4.994V
372.468
42.57°C
230.32V
60%
26.728A
6.01A
6.042A
2A
389.242
86.683%
1669
43
36.87°C
0.958
12.327V
4.993V
3.277V
4.976V
449.04
43.78°C
230.32V
70%
31.303A
7.036A
7.075A
2.218A
454.624
85.997%
1815
44.8
37.15°C
0.965
12.316V
4.975V
3.265V
4.956V
528.653
44.49°C
230.32V
80%
35.881A
8.002A
8.108A
2.326A
519.03
85.398%
1810
44.8
37.85°C
0.971
12.304V
4.957V
3.255V
4.943V
607.778
45.76°C
230.31V
90%
40.933A
8.587A
8.63A
2.435A
584.782
84.627%
2015
47.3
38.98°C
0.974
12.271V
4.949V
3.243V
4.927V
691.018
47.43°C
230.32V
100%
45.990A
9.102A
9.188A
2.545A
649.515
83.547%
2102
48.3
40.47°C
0.977
12.227V
4.944V
3.231V
4.91V
777.423
49.73°C
230.31V
110%
50.689A
10.152A
10.34A
2.552A
714.955
82.432%
2141
48.7
40.76°C
0.978
12.215V
4.925V
3.219V
4.897V
867.332
50.62°C
230.31V
CL1
3.724A
13.077A
12.659A
0.495A
155.39
79.365%
1812
44.8
36.93°C
0.916
12.889V
4.833V
3.293V
5.045V
195.79
42.57°C
230.32V
CL2
3.659A
20.385A
1A
0.495A
150.502
80.071%
1608
41.9
37.99°C
0.914
13.119V
4.744V
3.3V
5.054V
187.96
44.13°C
230.32V
CL3
3.876A
0.991A
18.443A
0.494A
116.488
75.65%
1517
40.7
38.95°C
0.901
12.385V
5.044V
3.307V
5.054V
153.982
46.71°C
230.32V
CL4
54.501A
0.972A
1.014A
0.5A
649.88
83.852%
1700
43.6
39.58°C
0.976
11.726V
5.144V
3.255V
4.999V
775.039
48.73°C
230.31V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.197A
0.491A
0.494A
0.196A
19.987
68.892%
1000
29.8
33.48°C
0.866
12.395V
5.09V
3.343V
5.1V
29.012
34.79°C
115.13V
40W
2.639A
0.688A
0.692A
0.294A
39.989
78.374%
1000
29.8
33.67°C
0.915
12.382V
5.088V
3.34V
5.094V
51.023
35.6°C
115.13V
60W
4.083A
0.885A
0.89A
0.393A
59.99
82.225%
1002
29.8
34.11°C
0.935
12.373V
5.085V
3.337V
5.087V
72.959
36.51°C
115.14V
80W
5.522A
1.083A
1.089A
0.492A
79.928
84.207%
998
29.7
34.52°C
0.96
12.367V
5.08V
3.334V
5.081V
94.92
37.48°C
115.14V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.197A
0.491A
0.494A
0.196A
19.99
69.582%
994
29.5
31.1°C
0.588
12.395V
5.089V
3.343V
5.1V
28.729
32.48°C
230.31V
40W
2.640A
0.688A
0.692A
0.294A
39.99
79.496%
995
29.4
31.53°C
0.733
12.382V
5.087V
3.34V
5.093V
50.304
33.47°C
230.31V
60W
4.083A
0.885A
0.89A
0.393A
59.991
83.441%
998
29.7
32.76°C
0.809
12.373V
5.084V
3.337V
5.087V
71.896
35.13°C
230.32V
80W
5.524A
1.082A
1.089A
0.492A
79.937
85.546%
999
29.7
33.34°C
0.849
12.365V
5.081V
3.333V
5.081V
93.444
36.42°C
230.32V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
18.13mV
10.37mV
12.89mV
8.15mV
Pass
20% Load
22.03mV
11.13mV
13.60mV
8.40mV
Pass
30% Load
23.64mV
11.44mV
12.79mV
9.41mV
Pass
40% Load
28.76mV
11.79mV
14.06mV
10.58mV
Pass
50% Load
30.83mV
13.72mV
14.21mV
12.24mV
Pass
60% Load
36.05mV
16.72mV
15.47mV
13.97mV
Pass
70% Load
42.18mV
19.56mV
16.18mV
15.13mV
Pass
80% Load
48.35mV
19.82mV
20.07mV
16.44mV
Pass
90% Load
52.75mV
22.87mV
21.74mV
18.67mV
Pass
100% Load
61.01mV
24.34mV
25.23mV
21.86mV
Pass
110% Load
77.97mV
29.37mV
25.93mV
23.73mV
Pass
Crossload1
23.85mV
21.19mV
22.19mV
9.87mV
Pass
Crossload2
26.73mV
23.37mV
11.07mV
8.40mV
Pass
Crossload3
18.78mV
11.99mV
30.03mV
12.14mV
Pass
Crossload4
60.45mV
17.84mV
21.84mV
21.25mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.16mV
10.42mV
12.59mV
8.10mV
Pass
20% Load
21.21mV
10.01mV
12.59mV
8.30mV
Pass
30% Load
20.86mV
9.61mV
12.99mV
8.35mV
Pass
40% Load
25.97mV
10.01mV
13.90mV
8.75mV
Pass
50% Load
27.80mV
11.43mV
14.36mV
9.67mV
Pass
60% Load
33.11mV
13.01mV
15.02mV
10.32mV
Pass
70% Load
40.20mV
16.31mV
15.82mV
11.89mV
Pass
80% Load
44.50mV
17.79mV
20.83mV
13.46mV
Pass
90% Load
50.98mV
21.04mV
21.99mV
17.30mV
Pass
100% Load
79.16mV
33.05mV
24.78mV
22.17mV
Pass
110% Load
87.76mV
36.86mV
27.56mV
25.55mV
Pass
Crossload1
25.86mV
21.28mV
23.58mV
11.39mV
Pass
Crossload2
23.90mV
20.89mV
10.67mV
8.80mV
Pass
Crossload3
16.46mV
10.93mV
29.78mV
12.30mV
Pass
Crossload4
81.52mV
26.24mV
21.82mV
21.95mV
Pass
The results above are not used in the certification process
Aresgame AGV650
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted