This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.213
66.355%
0.060
5.036V
0.321
115.04V
2
0.088A
0.442
73.544%
0.107
5.035V
0.601
115.04V
3
0.543A
2.726
79.060%
0.310
5.023V
3.448
115.04V
4
1.003A
5.026
78.864%
0.362
5.013V
6.373
115.04V
5
1.502A
7.513
79.118%
0.390
5.002V
9.496
115.04V
6
3.001A
14.907
74.793%
0.435
4.967V
19.931
115.04V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.736A
1.984A
1.947A
1.001A
42.790
74.202%
863
19.3
34.44°C
0.908
12.207V
5.042V
3.388V
4.994V
57.667
38.97°C
115.09V
2
4.509A
2.970A
2.930A
1.203A
85.769
80.989%
965
22.9
34.80°C
0.942
12.181V
5.036V
3.378V
4.980V
105.902
39.59°C
115.11V
3
7.644A
3.475A
3.438A
1.405A
128.932
83.018%
1107
27.2
35.09°C
0.962
12.147V
5.042V
3.368V
4.968V
155.306
40.47°C
115.11V
4
10.780A
3.963A
3.925A
1.612A
171.757
83.635%
1278
31.9
35.90°C
0.972
12.113V
5.048V
3.360V
4.954V
205.366
41.77°C
115.12V
5
13.594A
4.962A
4.925A
1.821A
214.799
83.485%
1504
36.1
37.56°C
0.977
12.086V
5.042V
3.349V
4.937V
257.290
43.94°C
115.12V
6
16.417A
5.955A
5.930A
2.030A
257.756
83.009%
1650
38.8
38.49°C
0.982
12.059V
5.037V
3.339V
4.920V
310.516
45.39°C
115.13V
7
19.261A
6.958A
6.938A
2.241A
300.815
82.312%
1800
42.0
39.66°C
0.984
12.031V
5.032V
3.328V
4.901V
365.459
47.27°C
115.14V
8
22.104A
7.959A
7.959A
2.453A
343.765
81.469%
1935
44.0
40.43°C
0.986
12.006V
5.026V
3.316V
4.888V
421.956
48.53°C
115.15V
9
25.441A
8.438A
8.497A
2.459A
386.883
80.531%
2046
45.2
41.10°C
0.987
11.960V
5.040V
3.306V
4.876V
480.414
50.39°C
115.16V
10
28.527A
8.919A
9.014A
3.090A
429.713
79.481%
2058
45.3
42.64°C
0.988
11.919V
5.047V
3.295V
4.849V
540.652
52.88°C
115.17V
11
32.252A
8.892A
9.033A
3.096A
472.626
78.482%
2058
45.3
44.08°C
0.988
11.873V
5.063V
3.287V
4.841V
602.207
55.92°C
115.19V
CL1
0.100A
14.026A
14.005A
0.004A
113.060
74.687%
2036
45.1
42.53°C
0.961
12.532V
4.636V
3.339V
4.957V
151.379
50.37°C
115.14V
CL2
33.966A
1.005A
1.002A
1.002A
410.814
79.772%
2036
45.1
44.36°C
0.988
11.694V
5.310V
3.327V
4.936V
514.988
54.14°C
115.17V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.203A
0.491A
0.469A
0.196A
19.727
64.507%
823
18.8
0.869
12.179V
5.088V
3.397V
5.026V
30.581
115.08V
2
2.423A
0.980A
0.970A
0.397A
39.761
75.082%
823
18.8
0.904
12.178V
5.075V
3.392V
5.015V
52.957
115.08V
3
3.652A
1.471A
1.474A
0.596A
59.880
79.208%
863
19.3
0.924
12.172V
5.067V
3.387V
5.004V
75.598
115.09V
4
4.869A
1.974A
1.951A
0.801A
79.815
81.250%
898
21.2
0.937
12.163V
5.062V
3.383V
4.996V
98.234
115.10V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
11.9 mV
6.8 mV
10.4 mV
14.8 mV
Pass
20% Load
14.4 mV
7.1 mV
10.4 mV
9.6 mV
Pass
30% Load
17.2 mV
8.2 mV
10.3 mV
11.6 mV
Pass
40% Load
21.0 mV
9.8 mV
10.7 mV
11.9 mV
Pass
50% Load
25.3 mV
12.1 mV
10.8 mV
13.9 mV
Pass
60% Load
29.2 mV
13.6 mV
11.4 mV
10.9 mV
Pass
70% Load
33.5 mV
15.3 mV
11.6 mV
19.7 mV
Pass
80% Load
37.5 mV
16.9 mV
11.8 mV
20.2 mV
Pass
90% Load
42.4 mV
20.4 mV
13.8 mV
20.6 mV
Pass
100% Load
46.1 mV
21.2 mV
14.4 mV
20.4 mV
Pass
110% Load
51.0 mV
22.8 mV
15.7 mV
20.9 mV
Pass
Crossload 1
27.8 mV
56.4 mV
18.5 mV
7.4 mV
Fail
Crossload 2
51.5 mV
17.4 mV
12.2 mV
11.9 mV
Pass
The results above are not used in the certification process