This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
转换效率图表
230V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
230V
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 230V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.230
42.125%
0.033
5.100V
0.546
230.27V
2
0.090A
0.459
53.621%
0.052
5.099V
0.856
230.27V
3
0.550A
2.801
71.236%
0.193
5.091V
3.932
230.25V
4
1.000A
5.084
72.962%
0.267
5.083V
6.968
230.25V
5
1.500A
7.614
73.851%
0.312
5.075V
10.310
230.25V
6
2.500A
12.646
72.724%
0.360
5.058V
17.389
230.25V
Supplementary Tests (For Reference)
10-110%负载测试 230V
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
1
2.365A
1.957A
1.952A
0.986A
50.003
79.244%
806
21.2
29.16°C
0.914
12.009V
5.111V
3.381V
5.071V
63.100
32.34°C
230.23V
2
5.762A
2.945A
2.937A
1.186A
100.025
85.118%
810
21.3
29.81°C
0.961
11.996V
5.096V
3.370V
5.058V
117.514
33.67°C
230.23V
3
9.527A
3.437A
3.438A
1.387A
149.978
86.980%
813
21.4
30.62°C
0.976
11.959V
5.091V
3.359V
5.046V
172.428
34.86°C
230.23V
4
13.319A
3.932A
3.941A
1.590A
200.020
87.587%
818
21.6
30.99°C
0.983
11.925V
5.084V
3.349V
5.033V
228.366
35.78°C
230.23V
5
16.742A
4.936A
4.943A
1.793A
250.048
87.513%
818
21.6
31.13°C
0.987
11.919V
5.066V
3.337V
5.019V
285.727
36.69°C
230.23V
6
20.173A
5.940A
5.954A
1.998A
300.000
87.149%
821
21.7
31.85°C
0.991
11.907V
5.050V
3.326V
5.005V
344.237
38.24°C
230.23V
7
23.629A
6.955A
6.971A
2.205A
350.080
86.613%
826
21.9
32.34°C
0.992
11.891V
5.033V
3.314V
4.989V
404.191
39.71°C
230.23V
8
27.084A
7.979A
7.998A
2.413A
400.117
85.683%
1050
28.7
32.75°C
0.993
11.878V
5.015V
3.300V
4.975V
466.973
40.73°C
230.23V
9
31.033A
8.485A
8.512A
2.418A
449.807
84.970%
1295
34.1
33.52°C
0.994
11.836V
5.009V
3.289V
4.964V
529.369
42.04°C
230.22V
10
34.995A
8.999A
9.062A
2.525A
500.131
84.150%
1572
39.4
34.82°C
0.994
11.799V
5.002V
3.278V
4.953V
594.335
44.18°C
230.23V
11
39.352A
8.995A
9.085A
2.529A
549.632
83.414%
1828
43.0
35.72°C
0.994
11.751V
5.003V
3.269V
4.945V
658.923
45.52°C
230.23V
CL1
4.001A
13.002A
12.999A
0.000A
156.616
81.925%
816
21.5
31.48°C
0.979
12.447V
4.887V
3.329V
5.043V
191.171
36.77°C
230.23V
CL2
37.981A
3.000A
2.999A
1.000A
466.601
85.214%
1426
37.0
35.21°C
0.994
11.487V
5.137V
3.303V
4.997V
547.565
44.75°C
230.23V
The results above are not used in the certification process
20-80瓦负载测试 230V
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
PF/AC 电压
1
1.243A
0.485A
0.486A
0.196A
19.994
67.947%
796
20.9
0.784
11.949V
5.144V
3.391V
5.093V
29.426
230.24V
2
2.483A
0.974A
0.975A
0.393A
39.983
78.122%
797
20.9
0.887
11.954V
5.135V
3.386V
5.086V
51.180
230.24V
3
3.726A
1.465A
1.464A
0.591A
60.014
82.200%
798
20.9
0.928
11.958V
5.125V
3.381V
5.078V
73.010
230.24V
4
4.963A
1.954A
1.953A
0.789A
79.964
84.289%
800
21.0
0.949
11.963V
5.117V
3.376V
5.069V
94.869
230.24V
The results above are not used in the certification process
纹波测量 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.50mV
8.00mV
14.50mV
9.00mV
Pass
20% Load
15.50mV
8.00mV
15.10mV
9.60mV
Pass
30% Load
16.70mV
9.00mV
15.30mV
9.70mV
Pass
40% Load
18.10mV
10.50mV
16.70mV
14.60mV
Pass
50% Load
20.70mV
11.20mV
17.50mV
11.40mV
Pass
60% Load
21.10mV
10.50mV
17.60mV
11.40mV
Pass
70% Load
22.20mV
10.80mV
18.80mV
13.10mV
Pass
80% Load
23.50mV
11.50mV
22.00mV
14.70mV
Pass
90% Load
22.80mV
13.00mV
22.60mV
16.30mV
Pass
100% Load
30.60mV
15.20mV
24.90mV
16.60mV
Pass
110% Load
33.90mV
16.50mV
24.40mV
19.50mV
Pass
Crossload1
16.20mV
17.50mV
25.00mV
7.80mV
Pass
Crossload2
30.00mV
20.00mV
20.20mV
16.90mV
Pass
The results above are not used in the certification process