SATA (510mm+150mm) / 4-pin Molex (+150mm) / FDD (+150mm)
1
2 / 1 / 1
18-22AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 230V
Efficiency Rating
BRONZE
Noise Rating
A-
Average Efficiency (>1450 load combinations)
85.499%
Average Noise Output (>1450 Load Combinations)
26.85dBA
Average PF (>1450 Load Combinations)
0.983
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.2443W
12V Ripple (Full Load)
30.59mV
5V Ripple (Full Load)
15.23mV
3.3V Ripple (Full Load)
24.91mV
5VSB Ripple (Full Load)
16.58mV
12V Load Regulation
1.75%
5V Load Regulation
2.67%
3.3V Load Regulation
3.10%
5VSB Load Regulation
2.69%
Inrush Current
70.810A
Hold-Up Time & Power Ok Signal
14.40ms
AC Loss to PWR_OK Hold Up Time
11.40ms
PWR_OK Inactive to DC Loss Delay
3.00ms
PSU Timings: T1 (20% / 100%)
60.0ms
62.0ms
PSU Timings: T3 (20% / 100%)
228.0ms
244.0ms
OPP (27.50°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
14.4
AC Loss to PWR_OK Hold Up Time (ms)
11.4
PWR_OK Inactive to DC Loss Delay (ms)
3
Vampire Power
Tables 230V
Graphs 230V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
42.125%
0.033
5.100V
0.546
230.27V
2
0.090A
0.459
53.621%
0.052
5.099V
0.856
230.27V
3
0.550A
2.801
71.236%
0.193
5.091V
3.932
230.25V
4
1.000A
5.084
72.962%
0.267
5.083V
6.968
230.25V
5
1.500A
7.614
73.851%
0.312
5.075V
10.310
230.25V
6
2.500A
12.646
72.724%
0.360
5.058V
17.389
230.25V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.365A
1.957A
1.952A
0.986A
50.003
79.244%
806
21.2
29.16°C
0.914
12.009V
5.111V
3.381V
5.071V
63.100
32.34°C
230.23V
2
5.762A
2.945A
2.937A
1.186A
100.025
85.118%
810
21.3
29.81°C
0.961
11.996V
5.096V
3.370V
5.058V
117.514
33.67°C
230.23V
3
9.527A
3.437A
3.438A
1.387A
149.978
86.980%
813
21.4
30.62°C
0.976
11.959V
5.091V
3.359V
5.046V
172.428
34.86°C
230.23V
4
13.319A
3.932A
3.941A
1.590A
200.020
87.587%
818
21.6
30.99°C
0.983
11.925V
5.084V
3.349V
5.033V
228.366
35.78°C
230.23V
5
16.742A
4.936A
4.943A
1.793A
250.048
87.513%
818
21.6
31.13°C
0.987
11.919V
5.066V
3.337V
5.019V
285.727
36.69°C
230.23V
6
20.173A
5.940A
5.954A
1.998A
300.000
87.149%
821
21.7
31.85°C
0.991
11.907V
5.050V
3.326V
5.005V
344.237
38.24°C
230.23V
7
23.629A
6.955A
6.971A
2.205A
350.080
86.613%
826
21.9
32.34°C
0.992
11.891V
5.033V
3.314V
4.989V
404.191
39.71°C
230.23V
8
27.084A
7.979A
7.998A
2.413A
400.117
85.683%
1050
28.7
32.75°C
0.993
11.878V
5.015V
3.300V
4.975V
466.973
40.73°C
230.23V
9
31.033A
8.485A
8.512A
2.418A
449.807
84.970%
1295
34.1
33.52°C
0.994
11.836V
5.009V
3.289V
4.964V
529.369
42.04°C
230.22V
10
34.995A
8.999A
9.062A
2.525A
500.131
84.150%
1572
39.4
34.82°C
0.994
11.799V
5.002V
3.278V
4.953V
594.335
44.18°C
230.23V
11
39.352A
8.995A
9.085A
2.529A
549.632
83.414%
1828
43.0
35.72°C
0.994
11.751V
5.003V
3.269V
4.945V
658.923
45.52°C
230.23V
CL1
4.001A
13.002A
12.999A
0.000A
156.616
81.925%
816
21.5
31.48°C
0.979
12.447V
4.887V
3.329V
5.043V
191.171
36.77°C
230.23V
CL2
37.981A
3.000A
2.999A
1.000A
466.601
85.214%
1426
37.0
35.21°C
0.994
11.487V
5.137V
3.303V
4.997V
547.565
44.75°C
230.23V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.243A
0.485A
0.486A
0.196A
19.994
67.947%
796
20.9
0.784
11.949V
5.144V
3.391V
5.093V
29.426
230.24V
2
2.483A
0.974A
0.975A
0.393A
39.983
78.122%
797
20.9
0.887
11.954V
5.135V
3.386V
5.086V
51.180
230.24V
3
3.726A
1.465A
1.464A
0.591A
60.014
82.200%
798
20.9
0.928
11.958V
5.125V
3.381V
5.078V
73.010
230.24V
4
4.963A
1.954A
1.953A
0.789A
79.964
84.289%
800
21.0
0.949
11.963V
5.117V
3.376V
5.069V
94.869
230.24V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.50mV
8.00mV
14.50mV
9.00mV
Pass
20% Load
15.50mV
8.00mV
15.10mV
9.60mV
Pass
30% Load
16.70mV
9.00mV
15.30mV
9.70mV
Pass
40% Load
18.10mV
10.50mV
16.70mV
14.60mV
Pass
50% Load
20.70mV
11.20mV
17.50mV
11.40mV
Pass
60% Load
21.10mV
10.50mV
17.60mV
11.40mV
Pass
70% Load
22.20mV
10.80mV
18.80mV
13.10mV
Pass
80% Load
23.50mV
11.50mV
22.00mV
14.70mV
Pass
90% Load
22.80mV
13.00mV
22.60mV
16.30mV
Pass
100% Load
30.60mV
15.20mV
24.90mV
16.60mV
Pass
110% Load
33.90mV
16.50mV
24.40mV
19.50mV
Pass
Crossload1
16.20mV
17.50mV
25.00mV
7.80mV
Pass
Crossload2
30.00mV
20.00mV
20.20mV
16.90mV