This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
转换效率图表
230V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
230V
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 230V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.229
42.251%
0.035
5.087V
0.542
230.28V
2
0.090A
0.458
54.137%
0.054
5.087V
0.846
230.28V
3
0.550A
2.793
71.487%
0.202
5.078V
3.907
230.26V
4
1.000A
5.070
73.118%
0.277
5.069V
6.934
230.27V
5
1.500A
7.593
73.984%
0.323
5.061V
10.263
230.26V
6
2.500A
12.606
72.779%
0.373
5.043V
17.321
230.27V
Supplementary Tests (For Reference)
10-110%负载测试 230V
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
1
1.496A
1.990A
1.948A
0.990A
40.003
78.596%
823
21.8
35.89°C
0.874
12.303V
5.024V
3.387V
5.053V
50.897
39.17°C
230.31V
2
3.998A
2.996A
2.932A
1.191A
80.022
84.354%
828
22.1
35.99°C
0.932
12.288V
5.007V
3.374V
5.038V
94.865
40.11°C
230.31V
3
6.852A
3.500A
3.433A
1.393A
119.977
86.064%
832
22.4
36.52°C
0.954
12.249V
5.000V
3.364V
5.024V
139.405
41.45°C
230.31V
4
9.723A
4.007A
3.935A
1.597A
160.017
86.438%
831
22.3
36.71°C
0.965
12.220V
4.992V
3.353V
5.012V
185.123
42.07°C
230.33V
5
12.252A
5.029A
4.941A
1.802A
200.049
86.159%
830
22.2
37.29°C
0.972
12.204V
4.974V
3.341V
4.996V
232.187
43.10°C
230.30V
6
14.768A
6.058A
5.947A
2.000A
239.938
85.636%
830
22.2
37.30°C
0.970
12.200V
4.954V
3.329V
4.980V
280.183
44.22°C
230.28V
7
17.318A
7.095A
6.966A
2.217A
280.056
84.565%
1249
33.1
38.20°C
0.971
12.180V
4.935V
3.317V
4.963V
331.171
45.39°C
230.27V
8
19.857A
8.002A
7.988A
2.426A
319.371
83.635%
1625
40.2
38.94°C
0.974
12.169V
4.916V
3.304V
4.947V
381.862
46.78°C
230.28V
9
22.858A
8.666A
8.503A
2.432A
359.981
82.765%
1932
44.5
39.36°C
0.979
12.139V
4.905V
3.293V
4.935V
434.942
48.10°C
230.28V
10
25.855A
9.190A
9.050A
2.540A
400.055
81.834%
2108
46.5
39.74°C
0.981
12.100V
4.897V
3.282V
4.923V
488.860
49.18°C
230.26V
11
29.353A
9.187A
9.078A
2.545A
440.122
80.851%
2104
46.5
40.29°C
0.983
12.023V
4.899V
3.272V
4.912V
544.364
50.04°C
230.30V
CL1
8.001A
12.000A
12.001A
0.000A
198.296
82.303%
1259
33.5
37.69°C
0.963
12.596V
4.810V
3.316V
4.999V
240.935
43.30°C
230.32V
CL2
30.007A
1.001A
0.999A
1.000A
361.136
83.208%
2048
45.5
39.79°C
0.977
11.588V
5.108V
3.321V
4.984V
434.017
49.13°C
230.30V
The results above are not used in the certification process
20-80瓦负载测试 230V
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
PF/AC 电压
1
1.215A
0.493A
0.486A
0.197A
19.990
72.895%
824
21.9
0.770
12.213V
5.068V
3.398V
5.077V
27.423
230.31V
2
2.429A
0.988A
0.972A
0.395A
39.980
81.054%
827
22.0
0.870
12.222V
5.055V
3.391V
5.068V
49.325
230.30V
3
3.646A
1.486A
1.461A
0.593A
60.010
84.043%
825
21.9
0.911
12.224V
5.044V
3.385V
5.059V
71.404
230.30V
4
4.856A
1.987A
1.951A
0.793A
79.959
85.490%
824
21.9
0.931
12.224V
5.034V
3.379V
5.048V
93.530
230.30V
The results above are not used in the certification process
纹波测量 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.60mV
5.80mV
7.70mV
9.30mV
Pass
20% Load
8.50mV
5.90mV
8.40mV
12.40mV
Pass
30% Load
10.30mV
6.30mV
8.40mV
10.80mV
Pass
40% Load
12.20mV
6.70mV
9.10mV
9.90mV
Pass
50% Load
12.20mV
7.90mV
10.00mV
17.60mV
Pass
60% Load
13.70mV
8.20mV
10.90mV
11.00mV
Pass
70% Load
11.40mV
8.10mV
12.40mV
12.00mV
Pass
80% Load
11.90mV
8.90mV
19.20mV
11.50mV
Pass
90% Load
14.10mV
10.00mV
20.00mV
12.50mV
Pass
100% Load
23.50mV
12.60mV
22.40mV
14.50mV
Pass
110% Load
27.50mV
13.20mV
22.10mV
14.80mV
Pass
Crossload1
13.20mV
14.90mV
24.80mV
7.90mV
Pass
Crossload2
20.70mV
10.40mV
10.10mV
13.20mV
Pass
The results above are not used in the certification process