This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228
47.010%
0.033
5.069V
0.485
230.32V
2
0.090A
0.456
58.612%
0.052
5.068V
0.778
230.32V
3
0.550A
2.779
74.166%
0.202
5.052V
3.747
230.32V
4
1.000A
5.037
75.224%
0.280
5.036V
6.696
230.32V
5
1.500A
7.530
75.648%
0.328
5.019V
9.954
230.32V
6
2.500A
12.457
75.187%
0.376
4.982V
16.568
230.32V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.174A
1.963A
1.945A
0.998A
60.004
79.778%
716
20.0
34.52°C
0.700
12.097V
5.097V
3.393V
5.013V
75.214
37.62°C
230.51V
2
7.376A
2.954A
2.926A
1.202A
120.031
85.496%
718
19.9
35.23°C
0.910
12.084V
5.079V
3.382V
4.992V
140.394
38.82°C
230.49V
3
11.956A
3.451A
3.426A
1.409A
180.034
87.058%
721
19.5
36.30°C
0.979
12.042V
5.073V
3.371V
4.970V
206.798
40.57°C
230.48V
4
16.572A
3.948A
3.929A
1.618A
240.037
87.459%
724
19.4
36.55°C
0.989
11.998V
5.066V
3.360V
4.947V
274.457
41.50°C
230.44V
5
20.830A
4.952A
4.932A
1.829A
300.074
87.157%
854
20.6
37.07°C
0.990
11.981V
5.049V
3.347V
4.921V
344.293
42.76°C
230.39V
6
25.081A
5.967A
5.936A
2.000A
359.827
86.459%
1191
30.9
37.56°C
0.990
11.970V
5.030V
3.335V
4.898V
416.184
43.86°C
230.39V
7
29.317A
6.989A
6.952A
2.259A
419.679
85.673%
1493
35.9
38.20°C
0.990
11.958V
5.009V
3.322V
4.871V
489.860
45.11°C
230.34V
8
33.629A
8.003A
7.974A
2.477A
480.091
84.828%
1836
41.5
38.40°C
0.991
11.947V
4.989V
3.310V
4.846V
565.957
46.11°C
230.37V
9
38.383A
8.538A
8.484A
2.485A
539.490
84.027%
2120
45.6
39.11°C
0.991
11.906V
4.979V
3.299V
4.830V
642.040
47.39°C
230.40V
10
43.233A
9.058A
9.034A
2.600A
600.222
83.087%
2392
50.5
39.22°C
0.991
11.866V
4.969V
3.288V
4.810V
722.405
48.66°C
230.37V
11
48.632A
9.055A
9.064A
2.609A
660.257
82.101%
2386
50.5
40.45°C
0.991
11.783V
4.972V
3.277V
4.792V
804.203
50.38°C
230.37V
CL1
6.001A
14.002A
14.000A
0.000A
190.303
80.919%
1250
32.1
37.25°C
0.985
12.599V
4.853V
3.339V
4.969V
235.177
43.13°C
230.42V
CL2
46.001A
2.001A
2.000A
1.000A
549.566
84.194%
2240
47.3
39.22°C
0.991
11.473V
5.130V
3.315V
4.902V
652.736
48.03°C
230.39V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.233A
0.487A
0.484A
0.198A
19.993
67.722%
721
19.5
0.432
12.041V
5.131V
3.404V
5.054V
29.522
230.44V
2
2.462A
0.977A
0.972A
0.397A
39.983
76.381%
718
19.9
0.582
12.053V
5.120V
3.400V
5.043V
52.347
230.48V
3
3.694A
1.469A
1.457A
0.597A
60.012
80.681%
718
19.9
0.695
12.062V
5.109V
3.395V
5.031V
74.382
230.52V
4
4.919A
1.961A
1.945A
0.798A
79.961
83.106%
718
19.9
0.791
12.068V
5.100V
3.391V
5.015V
96.216
230.48V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.80mV
5.10mV
4.30mV
7.50mV
Pass
20% Load
5.80mV
5.10mV
4.60mV
8.50mV
Pass
30% Load
6.60mV
5.00mV
4.80mV
9.60mV
Pass
40% Load
6.40mV
5.20mV
5.20mV
11.20mV
Pass
50% Load
7.60mV
5.70mV
5.30mV
11.40mV
Pass
60% Load
10.20mV
5.40mV
5.60mV
11.70mV
Pass
70% Load
14.30mV
5.60mV
5.90mV
14.80mV
Pass
80% Load
14.10mV
6.30mV
13.80mV
13.40mV
Pass
90% Load
16.00mV
6.90mV
14.10mV
14.00mV
Pass
100% Load
25.00mV
10.10mV
16.60mV
17.30mV
Pass
110% Load
22.70mV
9.60mV
17.90mV
16.90mV
Pass
Crossload1
7.10mV
8.80mV
15.80mV
7.40mV
Pass
Crossload2
22.30mV
7.70mV
9.70mV
14.30mV
Pass
The results above are not used in the certification process
SilverStone Strider Essential 600W 230V
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted