This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.229
46.830%
0.033
5.077V
0.489
230.32V
2
0.090A
0.457
58.291%
0.052
5.076V
0.784
230.32V
3
0.550A
2.786
74.293%
0.200
5.064V
3.750
230.32V
4
1.000A
5.052
75.302%
0.278
5.051V
6.709
230.32V
5
1.500A
7.562
75.886%
0.324
5.040V
9.965
230.31V
6
2.500A
12.537
75.702%
0.372
5.015V
16.561
230.30V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.026A
1.955A
1.942A
0.994A
69.999
82.636%
726
18.1
35.18°C
0.751
12.021V
5.116V
3.398V
5.031V
84.708
38.07°C
230.38V
2
9.094A
2.941A
2.921A
1.197A
140.028
87.077%
728
18.1
35.30°C
0.958
12.000V
5.102V
3.388V
5.012V
160.809
38.57°C
230.36V
3
14.548A
3.435A
3.419A
1.402A
210.032
88.108%
730
18.2
35.86°C
0.985
11.959V
5.095V
3.378V
4.994V
238.381
39.75°C
230.35V
4
20.055A
3.931A
3.919A
1.609A
280.041
88.169%
736
18.0
36.91°C
0.988
11.909V
5.088V
3.369V
4.973V
317.620
41.10°C
230.36V
5
25.238A
4.929A
4.913A
1.819A
350.065
87.555%
899
23.8
37.23°C
0.988
11.869V
5.075V
3.358V
4.949V
399.822
42.33°C
230.35V
6
30.389A
5.933A
5.912A
2.000A
419.837
86.752%
1108
28.2
37.77°C
0.989
11.852V
5.058V
3.349V
4.929V
483.950
43.90°C
230.33V
7
35.573A
6.945A
6.920A
2.242A
490.079
85.824%
1383
33.8
38.08°C
0.989
11.834V
5.040V
3.339V
4.906V
571.030
44.89°C
230.32V
8
40.784A
7.967A
7.931A
2.457A
560.199
84.807%
1645
35.9
38.48°C
0.990
11.813V
5.023V
3.328V
4.886V
660.559
45.78°C
230.31V
9
46.515A
8.474A
8.437A
2.464A
629.900
83.727%
2026
44.7
38.92°C
0.991
11.768V
5.017V
3.318V
4.872V
752.327
47.51°C
230.30V
10
52.314A
8.983A
8.976A
2.576A
700.217
82.551%
2361
50.4
39.72°C
0.991
11.718V
5.010V
3.308V
4.854V
848.228
48.87°C
230.29V
11
58.706A
8.973A
9.003A
2.585A
769.834
81.015%
2349
50.2
40.33°C
0.992
11.628V
5.016V
3.298V
4.836V
950.235
50.29°C
230.31V
CL1
5.999A
16.000A
16.000A
0.000A
206.347
81.173%
1015
25.2
37.65°C
0.987
12.580V
4.829V
3.351V
4.981V
254.205
42.51°C
230.36V
CL2
54.007A
3.000A
3.001A
1.000A
647.201
83.580%
2116
45.5
40.01°C
0.991
11.422V
5.144V
3.326V
4.920V
774.348
48.74°C
230.31V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.237A
0.487A
0.485A
0.197A
19.986
67.338%
727
18.1
0.400
11.987V
5.148V
3.408V
5.067V
29.680
230.33V
2
2.474A
0.974A
0.968A
0.396A
39.978
78.026%
727
18.1
0.577
11.995V
5.138V
3.404V
5.056V
51.237
230.35V
3
3.712A
1.463A
1.456A
0.595A
60.008
81.825%
726
18.1
0.704
12.002V
5.128V
3.401V
5.046V
73.337
230.38V
4
4.943A
1.954A
1.944A
0.794A
79.958
84.095%
723
19.4
0.793
12.008V
5.118V
3.397V
5.036V
95.080
230.38V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.40mV
4.70mV
4.30mV
7.60mV
Pass
20% Load
6.10mV
5.50mV
5.30mV
8.20mV
Pass
30% Load
6.40mV
6.70mV
6.00mV
8.90mV
Pass
40% Load
7.10mV
7.00mV
6.40mV
9.60mV
Pass
50% Load
9.30mV
8.20mV
6.90mV
11.00mV
Pass
60% Load
12.30mV
8.90mV
8.00mV
12.10mV
Pass
70% Load
14.80mV
9.50mV
9.40mV
17.40mV
Pass
80% Load
14.90mV
10.10mV
15.90mV
13.00mV
Pass
90% Load
18.50mV
12.10mV
17.90mV
14.30mV
Pass
100% Load
25.50mV
15.60mV
20.30mV
16.60mV
Pass
110% Load
29.90mV
16.70mV
20.80mV
17.50mV
Pass
Crossload1
8.30mV
7.70mV
19.00mV
10.60mV
Pass
Crossload2
19.10mV
14.50mV
11.80mV
11.20mV
Pass
The results above are not used in the certification process
SilverStone Strider Essential 700W 230V
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted