This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
62.331%
0.024
5.100V
0.369
230.33V
2
0.090A
0.459
68.713%
0.043
5.098V
0.668
230.33V
3
0.550A
2.794
76.110%
0.194
5.079V
3.671
230.35V
4
1.000A
5.061
76.025%
0.278
5.060V
6.657
230.33V
5
1.500A
7.564
76.166%
0.332
5.041V
9.931
230.33V
6
2.500A
12.506
74.467%
0.388
5.002V
16.794
230.31V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
0.261A
2.058A
1.951A
0.992A
24.960
69.157%
664
13.3
30.77°C
0.820
12.853V
4.862V
3.381V
5.044V
36.092
34.29°C
230.31V
2
1.551A
3.017A
2.938A
1.195A
50.021
77.548%
677
14.0
30.82°C
0.897
12.328V
4.973V
3.368V
5.023V
64.503
34.88°C
230.30V
3
3.176A
3.522A
3.442A
1.399A
75.011
81.117%
683
13.6
31.00°C
0.923
12.265V
4.970V
3.356V
5.005V
92.473
35.77°C
230.30V
4
4.804A
4.036A
3.945A
1.605A
100.001
82.725%
695
14.0
31.45°C
0.941
12.237V
4.958V
3.346V
4.987V
120.883
37.19°C
230.25V
5
6.082A
5.075A
4.953A
1.813A
124.989
83.106%
708
14.6
32.37°C
0.952
12.245V
4.928V
3.332V
4.965V
150.397
38.58°C
230.27V
6
7.367A
6.126A
5.968A
2.000A
149.940
83.105%
705
14.8
32.54°C
0.957
12.251V
4.898V
3.317V
4.943V
180.423
39.66°C
230.28V
7
8.635A
7.199A
6.995A
2.236A
174.995
82.776%
707
14.6
33.41°C
0.962
12.262V
4.864V
3.302V
4.919V
211.407
41.16°C
230.28V
8
9.917A
8.002A
8.028A
2.451A
198.722
82.416%
893
19.6
33.70°C
0.966
12.263V
4.838V
3.288V
4.896V
241.121
42.34°C
230.28V
9
11.621A
8.835A
8.549A
2.458A
224.953
82.053%
1056
24.3
34.93°C
0.968
12.258V
4.811V
3.275V
4.882V
274.156
44.25°C
230.30V
10
13.297A
9.399A
9.102A
2.570A
250.017
81.728%
1280
31.2
35.07°C
0.970
12.245V
4.788V
3.262V
4.865V
305.915
45.15°C
230.30V
11
15.394A
9.410A
9.130A
2.575A
275.062
81.686%
1341
32.1
35.52°C
0.972
12.203V
4.783V
3.253V
4.855V
336.730
46.26°C
230.31V
CL1
5.767A
10.999A
10.997A
0.001A
160.378
80.419%
715
15.2
32.56°C
0.961
12.489V
4.745V
3.288V
4.990V
199.427
38.64°C
230.28V
CL2
20.002A
1.002A
1.000A
1.000A
245.249
84.689%
1026
23.8
35.35°C
0.970
11.592V
5.090V
3.313V
4.973V
289.588
44.88°C
230.29V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.237A
0.488A
0.485A
0.197A
19.983
69.620%
685
13.8
0.775
11.998V
5.112V
3.392V
5.086V
28.703
230.31V
2
2.467A
0.983A
0.973A
0.395A
39.975
78.401%
687
13.8
0.871
12.031V
5.086V
3.383V
5.069V
50.988
230.29V
3
3.695A
1.481A
1.467A
0.594A
60.006
81.907%
687
13.8
0.907
12.059V
5.062V
3.374V
5.053V
73.261
230.21V
4
4.912A
1.985A
1.963A
0.794A
79.956
83.438%
688
13.8
0.925
12.083V
5.038V
3.365V
5.036V
95.827
230.27V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.00mV
19.50mV
7.60mV
12.90mV
Pass
20% Load
7.40mV
28.00mV
10.50mV
15.80mV
Pass
30% Load
8.60mV
28.90mV
11.10mV
13.90mV
Pass
40% Load
8.10mV
28.00mV
11.40mV
13.00mV
Pass
50% Load
8.00mV
28.50mV
12.10mV
22.10mV
Pass
60% Load
8.40mV
29.40mV
12.30mV
13.90mV
Pass
70% Load
10.00mV
30.40mV
13.60mV
15.30mV
Pass
80% Load
9.30mV
30.00mV
23.00mV
16.30mV
Pass
90% Load
9.90mV
31.40mV
23.00mV
17.30mV
Pass
100% Load
14.50mV
36.00mV
25.70mV
18.90mV
Pass
110% Load
15.40mV
36.30mV
26.20mV
19.00mV
Pass
Crossload1
22.90mV
20.90mV
7.60mV
7.30mV
Pass
Crossload2
17.50mV
21.60mV
12.40mV
15.70mV
Pass
The results above are not used in the certification process