This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.209
67.203%
0.058
5.032V
0.311
115.14V
2
0.087A
0.437
74.446%
0.104
5.032V
0.587
115.14V
3
0.542A
2.722
80.509%
0.310
5.022V
3.381
115.10V
4
1.002A
5.026
80.352%
0.362
5.016V
6.255
115.22V
5
1.501A
7.515
80.417%
0.391
5.005V
9.345
115.13V
6
3.002A
14.943
76.737%
0.437
4.978V
19.473
115.13V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.107A
1.965A
1.950A
1.001A
59.809
77.028%
787
15.6
38.13°C
0.916
12.303V
5.088V
3.378V
4.993V
77.646
41.89°C
115.18V
2
7.243A
2.950A
2.938A
1.202A
119.794
82.898%
822
16.2
38.37°C
0.952
12.280V
5.077V
3.365V
4.980V
144.507
43.18°C
115.18V
3
11.740A
3.447A
3.456A
1.405A
179.863
84.693%
873
17.4
38.87°C
0.963
12.248V
5.076V
3.355V
4.967V
212.371
43.88°C
115.18V
4
16.253A
3.943A
3.945A
1.615A
239.769
85.220%
1040
22.8
39.29°C
0.969
12.218V
5.074V
3.343V
4.950V
281.354
44.62°C
115.19V
5
20.440A
4.942A
4.949A
1.820A
299.743
85.066%
1240
27.6
39.70°C
0.975
12.195V
5.062V
3.330V
4.934V
352.364
45.84°C
115.19V
6
24.643A
5.938A
5.969A
2.035A
359.708
84.629%
1450
32.1
41.06°C
0.980
12.171V
5.051V
3.316V
4.910V
425.043
47.68°C
115.19V
7
28.865A
6.950A
6.993A
2.245A
419.697
84.001%
1630
35.9
41.89°C
0.983
12.146V
5.039V
3.302V
4.896V
499.636
49.37°C
115.20V
8
33.107A
7.956A
8.027A
2.455A
479.604
83.231%
1795
38.5
42.64°C
0.985
12.119V
5.028V
3.288V
4.882V
576.235
51.36°C
115.21V
9
37.822A
8.464A
8.573A
2.460A
539.682
82.402%
1938
40.5
44.40°C
0.986
12.085V
5.026V
3.276V
4.869V
654.939
53.49°C
115.22V
10
42.322A
8.957A
9.101A
3.095A
599.492
81.473%
2015
41.4
45.64°C
0.986
12.046V
5.024V
3.263V
4.842V
735.813
56.15°C
115.23V
11
47.459A
8.949A
9.132A
3.102A
659.451
80.540%
2015
41.4
46.36°C
0.986
12.005V
5.031V
3.252V
4.831V
818.604
57.18°C
115.25V
CL1
0.098A
16.027A
16.004A
0.004A
129.078
74.742%
1960
40.8
45.75°C
0.959
12.653V
4.664V
3.316V
4.952V
172.697
54.44°C
115.20V
CL2
48.961A
1.004A
1.002A
1.001A
595.062
81.696%
1980
41.1
46.38°C
0.986
11.879V
5.219V
3.294V
4.909V
728.390
55.47°C
115.24V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.187A
0.483A
0.468A
0.196A
19.640
61.707%
768
15.2
0.860
12.295V
5.124V
3.390V
5.023V
31.828
115.18V
2
2.400A
0.966A
0.973A
0.396A
39.727
73.075%
787
15.6
0.893
12.296V
5.112V
3.385V
5.012V
54.365
115.18V
3
3.614A
1.467A
1.476A
0.596A
59.875
77.714%
787
15.6
0.915
12.292V
5.100V
3.380V
5.004V
77.045
115.18V
4
4.817A
1.966A
1.954A
0.801A
79.806
80.379%
787
15.6
0.932
12.289V
5.093V
3.375V
4.997V
99.287
115.18V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.9 mV
15.5 mV
14.0 mV
18.7 mV
Pass
20% Load
13.8 mV
19.3 mV
17.6 mV
17.2 mV
Pass
30% Load
14.7 mV
20.7 mV
15.0 mV
17.5 mV
Pass
40% Load
15.8 mV
20.2 mV
15.3 mV
20.1 mV
Pass
50% Load
18.1 mV
21.4 mV
16.0 mV
20.2 mV
Pass
60% Load
20.9 mV
21.7 mV
17.7 mV
20.9 mV
Pass
70% Load
23.0 mV
23.3 mV
21.7 mV
23.4 mV
Pass
80% Load
25.2 mV
25.8 mV
24.3 mV
26.3 mV
Pass
90% Load
28.7 mV
25.8 mV
27.4 mV
25.2 mV
Pass
100% Load
32.4 mV
28.8 mV
26.0 mV
25.0 mV
Pass
110% Load
36.3 mV
26.5 mV
25.5 mV
26.3 mV
Pass
Crossload 1
34.3 mV
62.0 mV
16.3 mV
21.5 mV
Fail
Crossload 2
37.9 mV
20.0 mV
24.5 mV
23.4 mV
Pass
The results above are not used in the certification process