BK BDH12025S (120mm, 12V, 0.18A, Hydraulic Bearing Fan)
5VSB Circuit
-
Standby PWM Controller
PR6249H
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Efficiency Rating
BRONZE
Noise Rating
Standard
Average Efficiency (>1450 load combinations)
83.042%
Average Noise Output (>1450 Load Combinations)
42.14dBA
Average PF (>1450 Load Combinations)
0.986
Efficiency With 10W (≤500W) or 2% (>500W) Load
53.369%
Standby Power Consumption
0.0615W
12V Ripple (Full Load)
49.18mV
5V Ripple (Full Load)
14.81mV
3.3V Ripple (Full Load)
25.50mV
5VSB Ripple (Full Load)
23.98mV
12V Load Regulation
1.47%
5V Load Regulation
2.29%
3.3V Load Regulation
2.08%
5VSB Load Regulation
3.29%
Inrush Current
41.900A
Efficiency Rating
Noise Rating
Standard
Average Efficiency (>1450 load combinations)
84.693%
Average Noise Output (>1450 Load Combinations)
42.38dBA
Average PF (>1450 Load Combinations)
0.825
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1940W
12V Ripple (Full Load)
35.87mV
5V Ripple (Full Load)
11.20mV
3.3V Ripple (Full Load)
21.62mV
5VSB Ripple (Full Load)
21.59mV
12V Load Regulation
1.51%
5V Load Regulation
2.48%
3.3V Load Regulation
2.05%
5VSB Load Regulation
3.27%
Inrush Current
75.720A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
17.40ms
AC Loss to PWR_OK Hold Up Time
12.50ms
PWR_OK Inactive to DC Loss Delay
4.90ms
PSU Timings: T1 (20% / 100%)
42.0ms
40.0ms
PSU Timings: T3 (20% / 100%)
273.0ms
276.0ms
OPP (25.00°C / 37.00°C)
120.89%
125.09%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
17.4
AC Loss to PWR_OK Hold Up Time (ms)
12.5
PWR_OK Inactive to DC Loss Delay (ms)
4.9
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
67.151%
0.068
5.140V
0.344
115.12V
2
0.090A
0.462
73.567%
0.116
5.139V
0.628
115.12V
3
0.550A
2.816
80.251%
0.318
5.122V
3.509
115.11V
4
1.000A
5.104
80.721%
0.365
5.106V
6.323
115.12V
5
1.500A
7.630
80.613%
0.391
5.087V
9.465
115.12V
6
2.999A
15.093
78.389%
0.433
5.033V
19.254
115.12V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
47.336%
0.030
5.141V
0.488
230.29V
2
0.090A
0.462
59.231%
0.047
5.139V
0.780
230.25V
3
0.550A
2.816
75.801%
0.180
5.122V
3.715
230.25V
4
1.000A
5.105
77.150%
0.248
5.106V
6.617
230.25V
5
1.500A
7.631
77.891%
0.287
5.088V
9.797
230.25V
6
2.999A
15.091
78.220%
0.341
5.032V
19.293
230.26V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.922A
1.956A
1.991A
0.981A
44.954
74.723%
1562
37.1
35.35°C
0.799
12.151V
5.110V
3.317V
5.098V
60.161
38.20°C
115.18V
2
4.870A
2.944A
2.992A
1.180A
90.014
81.746%
1654
39.8
35.83°C
0.942
12.138V
5.096V
3.309V
5.084V
110.114
39.00°C
115.17V
3
8.174A
3.434A
3.495A
1.380A
134.996
84.262%
1766
40.7
36.29°C
0.979
12.106V
5.096V
3.303V
5.071V
160.209
40.38°C
115.17V
4
11.493A
3.926A
4.002A
1.582A
179.988
85.296%
1862
42.3
36.97°C
0.997
12.076V
5.095V
3.297V
5.057V
211.016
41.48°C
115.16V
5
14.460A
4.921A
5.016A
1.785A
224.973
84.997%
2018
45.3
37.63°C
0.996
12.066V
5.080V
3.289V
5.043V
264.685
42.95°C
115.17V
6
17.433A
5.923A
6.035A
1.989A
269.956
84.656%
2126
45.1
37.71°C
0.995
12.055V
5.065V
3.281V
5.028V
318.884
43.82°C
115.16V
7
20.421A
6.931A
7.059A
2.193A
315.016
84.142%
2292
48.2
38.54°C
0.994
12.042V
5.051V
3.273V
5.013V
374.384
45.61°C
115.15V
8
23.399A
7.949A
8.085A
2.400A
359.994
83.476%
2359
48.4
39.32°C
0.994
12.034V
5.034V
3.265V
4.999V
431.256
47.35°C
115.15V
9
26.848A
8.446A
8.589A
2.402A
404.733
82.803%
2401
48.3
39.38°C
0.994
12.003V
5.032V
3.258V
4.993V
488.788
48.04°C
115.15V
10
30.060A
8.947A
9.134A
3.022A
449.566
81.965%
2443
49.0
40.54°C
0.994
11.972V
5.029V
3.251V
4.963V
548.486
49.53°C
115.14V
11
33.945A
8.926A
9.150A
3.025A
494.375
81.153%
2444
49.0
41.20°C
0.994
11.922V
5.041V
3.245V
4.957V
609.189
51.04°C
115.14V
CL1
4.000A
11.997A
11.998A
0.001A
147.476
79.132%
2087
44.8
37.89°C
0.987
12.411V
4.871V
3.283V
5.107V
186.366
42.82°C
115.16V
CL2
36.001A
1.000A
1.000A
1.000A
432.152
82.869%
2389
48.2
40.03°C
0.995
11.626V
5.276V
3.272V
5.056V
521.489
49.10°C
115.14V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.922A
1.955A
1.989A
0.980A
44.951
74.693%
1699
39.3
35.11°C
0.365
12.154V
5.112V
3.318V
5.099V
60.181
37.23°C
230.32V
2
4.869A
2.943A
2.991A
1.180A
90.011
82.586%
1681
40.3
35.31°C
0.533
12.140V
5.097V
3.310V
5.085V
108.990
37.88°C
230.27V
3
8.172A
3.434A
3.497A
1.380A
134.990
85.065%
1795
40.9
36.69°C
0.638
12.107V
5.097V
3.303V
5.071V
158.691
39.81°C
230.28V
4
11.493A
3.926A
4.003A
1.582A
179.991
86.067%
1853
42.5
37.06°C
0.737
12.076V
5.095V
3.297V
5.057V
209.129
40.80°C
230.30V
5
14.458A
4.925A
5.019A
1.785A
224.983
86.472%
1989
43.6
37.43°C
0.826
12.067V
5.078V
3.289V
5.043V
260.179
42.34°C
230.32V
6
17.436A
5.925A
6.037A
1.989A
269.974
86.467%
2160
45.8
37.78°C
0.893
12.053V
5.065V
3.281V
5.028V
312.229
42.96°C
230.32V
7
20.412A
6.940A
7.058A
2.194A
315.038
86.216%
2134
45.3
38.06°C
0.924
12.048V
5.045V
3.273V
5.014V
365.405
44.66°C
230.34V
8
23.407A
7.949A
8.086A
2.400A
360.015
85.787%
2336
48.5
38.73°C
0.947
12.031V
5.033V
3.265V
4.999V
419.660
46.42°C
230.34V
9
26.856A
8.448A
8.593A
2.403A
404.813
85.354%
2401
48.5
39.51°C
0.966
12.002V
5.030V
3.258V
4.993V
474.278
47.90°C
230.33V
10
30.068A
8.950A
9.132A
3.022A
449.630
84.849%
2428
48.8
40.14°C
0.977
11.971V
5.028V
3.251V
4.963V
529.920
49.36°C
230.33V
11
33.953A
8.929A
9.149A
3.026A
494.435
84.339%
2436
48.9
40.61°C
0.984
11.921V
5.039V
3.245V
4.957V
586.250
50.41°C
230.33V
CL1
4.000A
11.999A
11.997A
0.001A
147.471
79.934%
2028
45.4
37.95°C
0.683
12.411V
4.870V
3.283V
5.106V
184.491
42.33°C
230.34V
CL2
36.004A
1.000A
1.000A
1.000A
432.292
85.653%
2368
48.5
40.48°C
0.973
11.629V
5.273V
3.273V
5.056V
504.703
49.82°C
230.34V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.227A
0.484A
0.496A
0.195A
19.986
63.397%
1589
37.3
0.587
12.093V
5.160V
3.324V
5.132V
31.525
115.17V
2
2.453A
0.972A
0.992A
0.391A
39.976
74.583%
1575
37.0
0.766
12.098V
5.147V
3.320V
5.121V
53.599
115.18V
3
3.681A
1.461A
1.493A
0.587A
60.005
79.326%
1512
38.0
0.860
12.103V
5.134V
3.317V
5.111V
75.644
115.18V
4
4.904A
1.950A
1.992A
0.784A
79.954
81.705%
1626
38.3
0.911
12.105V
5.124V
3.313V
5.101V
97.857
115.18V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.226A
0.484A
0.496A
0.195A
19.981
64.442%
1322
34.5
0.273
12.098V
5.160V
3.325V
5.134V
31.006
230.33V
2
2.452A
0.970A
0.994A
0.390A
39.970
75.901%
1487
35.8
0.330
12.103V
5.148V
3.321V
5.124V
52.661
230.33V
3
3.680A
1.461A
1.491A
0.587A
60.001
80.230%
1566
37.0
0.439
12.106V
5.136V
3.317V
5.113V
74.786
230.33V
4
4.902A
1.951A
1.991A
0.784A
79.952
82.611%
1569
37.0
0.496
12.108V
5.125V
3.314V
5.103V
96.781
230.33V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.30mV
8.10mV
13.50mV
11.90mV
Pass
20% Load
16.40mV
17.30mV
17.00mV
40.60mV
Pass
30% Load
14.70mV
8.90mV
15.30mV
14.40mV
Pass
40% Load
14.40mV
7.80mV
14.80mV
13.90mV
Pass
50% Load
24.90mV
20.70mV
19.70mV
47.90mV
Pass
60% Load
20.10mV
7.60mV
16.50mV
16.40mV
Pass
70% Load
24.40mV
7.90mV
17.80mV
16.60mV
Pass
80% Load
29.90mV
9.30mV
23.00mV
18.70mV
Pass
90% Load
35.20mV
21.70mV
24.30mV
46.30mV
Pass
100% Load
49.20mV
14.80mV
25.50mV
24.00mV
Pass
110% Load
67.30mV
18.00mV
23.60mV
23.60mV
Pass
Crossload1
24.20mV
15.90mV
29.30mV
24.80mV
Pass
Crossload2
58.10mV
11.20mV
11.50mV
16.90mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.90mV
7.80mV
13.90mV
12.50mV
Pass
20% Load
13.70mV
8.70mV
14.70mV
13.10mV
Pass
30% Load
14.40mV
7.40mV
15.30mV
13.50mV
Pass
40% Load
14.90mV
7.00mV
14.80mV
13.90mV
Pass
50% Load
16.50mV
8.30mV
15.80mV
15.20mV
Pass
60% Load
19.10mV
6.70mV
16.00mV
15.70mV
Pass
70% Load
21.50mV
8.10mV
17.10mV
17.00mV
Pass
80% Load
23.50mV
7.00mV
20.10mV
18.00mV
Pass
90% Load
29.20mV
9.10mV
21.10mV
18.40mV
Pass
100% Load
35.90mV
11.20mV
21.60mV
21.60mV
Pass
110% Load
47.80mV
11.60mV
21.00mV
23.00mV
Pass
Crossload1
23.20mV
17.50mV
28.80mV
25.50mV
Pass
Crossload2
51.50mV
8.90mV
11.20mV
16.80mV
Pass
The results above are not used in the certification process
Gigabyte P450B
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted