This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.214
68.153%
0.051
5.132V
0.314
115.19V
2
0.087A
0.447
73.520%
0.096
5.130V
0.608
115.19V
3
0.542A
2.774
77.313%
0.333
5.119V
3.588
115.18V
4
1.002A
5.118
77.346%
0.405
5.108V
6.617
115.19V
5
1.502A
7.652
77.153%
0.441
5.096V
9.918
115.19V
6
3.001A
15.158
75.980%
0.485
5.051V
19.950
115.19V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.734A
1.996A
1.980A
0.981A
54.779
83.958%
0
<6.0
47.11°C
0.946
12.141V
5.008V
3.328V
5.097V
65.246
38.61°C
115.20V
2
6.497A
2.992A
2.975A
1.179A
109.735
88.540%
0
<6.0
48.21°C
0.979
12.141V
5.005V
3.323V
5.084V
123.939
39.00°C
115.20V
3
10.607A
3.504A
3.489A
1.379A
164.892
89.718%
0
<6.0
49.90°C
0.986
12.142V
5.001V
3.321V
5.070V
183.790
39.35°C
115.20V
4
14.709A
4.008A
3.973A
1.580A
219.801
89.850%
645
11.9
39.49°C
0.989
12.142V
4.998V
3.318V
5.057V
244.633
59.63°C
115.19V
5
18.465A
5.009A
4.977A
1.783A
274.694
89.539%
550
10.4
40.75°C
0.990
12.143V
4.990V
3.313V
5.042V
306.786
61.01°C
115.19V
6
22.230A
6.016A
5.980A
1.986A
329.684
89.021%
560
10.5
41.00°C
0.990
12.142V
4.986V
3.309V
5.027V
370.342
63.75°C
115.19V
7
25.990A
7.024A
6.985A
2.194A
384.637
88.467%
880
20.6
41.63°C
0.990
12.142V
4.981V
3.305V
5.011V
434.780
61.30°C
115.21V
8
29.753A
8.046A
7.999A
2.400A
439.575
87.623%
1325
31.4
42.45°C
0.991
12.139V
4.975V
3.299V
4.994V
501.668
58.38°C
115.23V
9
33.952A
8.552A
8.523A
2.405A
494.626
86.792%
1850
40.2
43.72°C
0.992
12.136V
4.970V
3.296V
4.985V
569.899
56.43°C
115.18V
10
37.892A
9.067A
9.020A
3.020A
549.503
85.891%
2310
45.1
44.95°C
0.992
12.134V
4.967V
3.293V
4.961V
639.765
57.10°C
115.17V
11
42.424A
9.070A
9.024A
3.026A
604.425
85.029%
2320
45.2
46.28°C
0.992
12.133V
4.964V
3.290V
4.951V
710.849
60.03°C
115.16V
CL1
0.099A
12.014A
12.004A
0.004A
100.991
85.016%
621
11.6
44.12°C
0.976
12.149V
4.991V
3.316V
5.091V
118.791
54.60°C
115.20V
CL2
44.972A
1.005A
1.004A
1.002A
558.916
86.521%
2310
45.1
45.36°C
0.992
12.131V
4.979V
3.304V
5.030V
645.992
57.63°C
115.18V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.202A
0.490A
0.479A
0.196A
19.643
71.080%
0
<6.0
0.783
12.134V
5.014V
3.333V
5.124V
27.635
115.20V
2
2.428A
0.991A
0.990A
0.391A
39.724
81.250%
0
<6.0
0.911
12.136V
5.008V
3.328V
5.116V
48.891
115.20V
3
3.658A
1.489A
1.499A
0.585A
59.832
85.206%
0
<6.0
0.952
12.137V
5.008V
3.328V
5.108V
70.220
115.20V
4
4.874A
1.996A
1.983A
0.781A
79.738
87.243%
0
<6.0
0.968
12.139V
5.007V
3.326V
5.099V
91.398
115.20V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
10.1 mV
5.6 mV
8.2 mV
6.3 mV
Pass
20% Load
12.7 mV
5.7 mV
8.7 mV
6.0 mV
Pass
30% Load
15.1 mV
6.1 mV
8.2 mV
5.7 mV
Pass
40% Load
16.4 mV
6.9 mV
8.3 mV
6.2 mV
Pass
50% Load
18.1 mV
6.6 mV
8.8 mV
6.6 mV
Pass
60% Load
19.6 mV
7.5 mV
9.7 mV
6.9 mV
Pass
70% Load
21.2 mV
8.2 mV
10.1 mV
8.0 mV
Pass
80% Load
22.8 mV
8.7 mV
9.9 mV
8.0 mV
Pass
90% Load
24.6 mV
10.4 mV
10.7 mV
7.9 mV
Pass
100% Load
26.4 mV
12.8 mV
12.7 mV
10.3 mV
Pass
110% Load
28.1 mV
13.1 mV
13.4 mV
10.2 mV
Pass
Crossload 1
15.6 mV
9.4 mV
8.6 mV
7.9 mV
Pass
Crossload 2
25.5 mV
10.8 mV
11.4 mV
9.5 mV
Pass
The results above are not used in the certification process