This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.215
67.398%
0.052
5.141V
0.319
115.19V
2
0.088A
0.450
73.171%
0.098
5.139V
0.615
115.16V
3
0.542A
2.780
76.987%
0.339
5.129V
3.611
115.19V
4
1.002A
5.130
77.247%
0.413
5.119V
6.641
115.19V
5
1.502A
7.669
77.168%
0.451
5.107V
9.938
115.18V
6
3.002A
15.193
75.176%
0.494
5.061V
20.210
115.16V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.552A
2.006A
1.989A
0.975A
64.778
84.178%
0
<6.0
45.35°C
0.955
12.162V
4.992V
3.310V
5.108V
76.954
38.31°C
115.19V
2
8.134A
3.000A
2.991A
1.176A
129.751
88.854%
0
<6.0
45.70°C
0.978
12.160V
4.988V
3.306V
5.094V
146.027
38.70°C
115.18V
3
13.056A
3.512A
3.508A
1.375A
194.838
89.918%
0
<6.0
46.41°C
0.985
12.160V
4.985V
3.302V
5.081V
216.685
39.21°C
115.18V
4
17.975A
4.016A
3.999A
1.575A
259.749
90.002%
459
9.9
40.35°C
0.988
12.160V
4.980V
3.298V
5.070V
288.609
50.35°C
115.18V
5
22.553A
5.023A
5.006A
1.778A
324.687
89.740%
550
10.4
40.44°C
0.990
12.159V
4.975V
3.293V
5.056V
361.808
52.16°C
115.19V
6
27.127A
6.039A
6.016A
1.980A
389.633
89.189%
560
10.5
41.06°C
0.990
12.159V
4.971V
3.290V
5.042V
436.862
53.23°C
115.18V
7
31.702A
7.044A
7.028A
2.185A
454.528
88.183%
845
20.4
42.18°C
0.991
12.159V
4.967V
3.285V
5.029V
515.439
54.65°C
115.17V
8
36.282A
8.068A
8.044A
2.391A
519.537
87.447%
1333
31.4
43.33°C
0.992
12.158V
4.962V
3.282V
5.013V
594.117
56.65°C
115.16V
9
41.291A
8.576A
8.570A
2.395A
584.530
86.660%
2007
41.6
44.01°C
0.992
12.156V
4.958V
3.278V
5.004V
674.508
57.58°C
115.15V
10
46.046A
9.085A
9.069A
3.009A
649.379
85.581%
2310
45.1
45.19°C
0.993
12.155V
4.954V
3.274V
4.982V
758.788
58.90°C
115.16V
11
51.391A
9.089A
9.078A
3.014A
714.294
84.662%
2140
44.3
46.73°C
0.993
12.154V
4.951V
3.271V
4.975V
843.697
60.89°C
115.15V
CL1
0.100A
12.014A
12.003A
0.004A
100.569
83.561%
0
0
42.96°C
0.973
12.166V
4.977V
3.294V
5.108V
120.354
47.41°C
115.20V
CL2
54.115A
1.005A
1.000A
1.002A
670.992
85.971%
2320
45.2
45.76°C
0.993
12.153V
4.965V
3.287V
5.045V
780.484
58.99°C
115.15V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.200A
0.495A
0.479A
0.191A
19.639
68.165%
0
<6.0
0.820
12.160V
5.002V
3.318V
5.134V
28.811
115.19V
2
2.424A
1.000A
0.995A
0.391A
39.772
79.434%
0
<6.0
0.919
12.161V
4.993V
3.313V
5.126V
50.069
115.19V
3
3.653A
1.499A
1.511A
0.585A
59.907
84.273%
0
<6.0
0.952
12.161V
4.993V
3.312V
5.119V
71.087
115.18V
4
4.868A
2.003A
1.991A
0.780A
79.773
86.254%
0
<6.0
0.963
12.161V
4.991V
3.310V
5.111V
92.486
115.18V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.0 mV
6.8 mV
7.8 mV
6.0 mV
Pass
20% Load
12.5 mV
6.9 mV
8.2 mV
6.0 mV
Pass
30% Load
14.5 mV
7.0 mV
7.3 mV
6.0 mV
Pass
40% Load
17.2 mV
7.6 mV
7.9 mV
6.6 mV
Pass
50% Load
18.8 mV
8.5 mV
9.1 mV
6.9 mV
Pass
60% Load
21.2 mV
9.1 mV
9.3 mV
7.6 mV
Pass
70% Load
22.2 mV
9.6 mV
8.9 mV
7.4 mV
Pass
80% Load
24.5 mV
11.1 mV
10.5 mV
9.2 mV
Pass
90% Load
25.5 mV
10.8 mV
12.4 mV
9.6 mV
Pass
100% Load
27.9 mV
12.3 mV
12.6 mV
10.8 mV
Pass
110% Load
28.8 mV
15.5 mV
13.3 mV
11.4 mV
Pass
Crossload 1
12.6 mV
10.3 mV
9.1 mV
9.0 mV
Pass
Crossload 2
28.3 mV
12.7 mV
14.7 mV
10.0 mV
Pass
The results above are not used in the certification process