This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.212
68.167%
0.050
5.128V
0.311
115.21V
2
0.087A
0.445
73.920%
0.095
5.126V
0.602
115.21V
3
0.542A
2.771
77.968%
0.329
5.116V
3.554
115.38V
4
1.002A
5.113
78.085%
0.400
5.105V
6.548
115.34V
5
1.501A
7.647
78.246%
0.436
5.094V
9.773
115.34V
6
3.001A
15.153
76.176%
0.485
5.049V
19.892
115.33V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.380A
1.996A
1.994A
0.981A
74.721
85.411%
0
|6
42.05°C
0.955
12.131V
5.012V
3.303V
5.095V
87.484
38.38°C
115.20V
2
9.797A
2.992A
2.999A
1.180A
149.732
89.414%
0
|6
42.62°C
0.983
12.132V
5.008V
3.299V
5.083V
167.459
38.80°C
115.20V
3
15.560A
3.498A
3.517A
1.379A
224.860
90.296%
700
14.6
38.85°C
0.989
12.132V
5.004V
3.295V
5.071V
249.026
52.18°C
115.19V
4
21.307A
4.004A
4.008A
1.580A
299.705
90.300%
550
10.4
39.00°C
0.991
12.132V
5.000V
3.292V
5.059V
331.900
53.36°C
115.19V
5
26.716A
5.002A
5.014A
1.780A
374.628
89.703%
560
10.5
40.37°C
0.990
12.134V
4.996V
3.288V
5.045V
417.633
55.25°C
115.27V
6
32.118A
6.016A
6.026A
1.985A
449.554
89.092%
735
15.4
40.60°C
0.991
12.135V
4.990V
3.284V
5.034V
504.597
55.86°C
115.17V
7
37.534A
7.018A
7.042A
2.190A
524.474
88.327%
1325
31.4
42.34°C
0.991
12.133V
4.986V
3.279V
5.019V
593.787
57.82°C
115.17V
8
42.959A
8.034A
8.062A
2.395A
599.416
87.492%
1960
41.4
43.07°C
0.992
12.128V
4.981V
3.275V
5.006V
685.112
59.02°C
115.16V
9
48.809A
8.539A
8.586A
2.400A
674.436
86.791%
2310
45.1
44.06°C
0.992
12.126V
4.977V
3.271V
4.998V
777.079
60.62°C
115.16V
10
54.388A
9.058A
9.085A
3.011A
749.284
85.960%
2320
45.2
45.87°C
0.993
12.127V
4.973V
3.268V
4.977V
871.661
62.87°C
115.15V
11
60.564A
9.067A
9.093A
3.015A
824.135
84.992%
2320
45.2
47.30°C
0.993
12.126V
4.970V
3.265V
4.970V
969.658
65.69°C
115.15V
CL1
0.099A
12.013A
12.004A
0.004A
100.757
84.378%
560
10.5
43.09°C
0.973
12.145V
4.998V
3.290V
5.101V
119.412
55.37°C
115.21V
CL2
61.936A
1.005A
1.002A
1.001A
764.309
86.243%
2320
45.2
46.36°C
0.993
12.125V
4.982V
3.279V
5.037V
886.231
62.78°C
115.16V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.205A
0.493A
0.482A
0.195A
19.665
68.239%
0
<6.0
0.750
12.115V
5.017V
3.308V
5.121V
28.818
115.20V
2
2.433A
0.991A
0.997A
0.391A
39.753
79.148%
0
<6.0
0.884
12.120V
5.015V
3.305V
5.114V
50.226
115.20V
3
3.665A
1.487A
1.509A
0.585A
59.862
83.966%
0
<6.0
0.938
12.124V
5.013V
3.304V
5.106V
71.293
115.20V
4
4.880A
1.996A
1.995A
0.780A
79.756
86.353%
0
<6.0
0.959
12.128V
5.012V
3.303V
5.099V
92.360
115.21V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.9 mV
6.0 mV
8.2 mV
5.7 mV
Pass
20% Load
12.7 mV
6.1 mV
8.5 mV
5.9 mV
Pass
30% Load
15.2 mV
6.3 mV
8.5 mV
6.1 mV
Pass
40% Load
17.1 mV
7.8 mV
10.4 mV
6.5 mV
Pass
50% Load
18.3 mV
7.8 mV
9.1 mV
6.5 mV
Pass
60% Load
20.2 mV
10.4 mV
10.6 mV
7.2 mV
Pass
70% Load
21.9 mV
11.4 mV
11.6 mV
8.4 mV
Pass
80% Load
23.0 mV
11.6 mV
11.8 mV
9.4 mV
Pass
90% Load
26.2 mV
13.1 mV
13.1 mV
9.8 mV
Pass
100% Load
27.9 mV
13.2 mV
14.6 mV
11.6 mV
Pass
110% Load
28.6 mV
15.4 mV
15.9 mV
12.2 mV
Pass
Crossload 1
12.3 mV
11.3 mV
9.4 mV
8.2 mV
Pass
Crossload 2
27.2 mV
10.6 mV
12.8 mV
9.2 mV
Pass
The results above are not used in the certification process