This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.213
70.297%
0.043
5.131V
0.303
115.17V
2
0.087A
0.446
75.850%
0.082
5.130V
0.588
115.19V
3
0.542A
2.776
80.162%
0.288
5.122V
3.463
115.17V
4
1.002A
5.119
79.205%
0.350
5.110V
6.463
115.18V
5
1.501A
7.657
77.422%
0.384
5.100V
9.890
115.18V
6
3.001A
15.204
74.669%
0.431
5.066V
20.362
115.18V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.529A
1.975A
1.965A
0.980A
64.769
76.505%
1677
40.8
38.45°C
0.980
12.242V
5.056V
3.353V
5.094V
84.660
40.82°C
115.19V
2
8.091A
2.973A
2.957A
1.181A
129.754
83.798%
1685
40.9
38.70°C
0.987
12.222V
5.038V
3.344V
5.080V
154.842
41.27°C
115.19V
3
13.012A
3.489A
3.474A
1.380A
194.886
85.941%
1692
41.0
39.02°C
0.980
12.202V
5.025V
3.336V
5.066V
226.767
41.74°C
115.18V
4
17.943A
3.992A
3.966A
1.580A
259.751
86.759%
1692
41.0
39.51°C
0.983
12.181V
5.013V
3.327V
5.051V
299.395
42.40°C
115.18V
5
22.553A
5.000A
4.971A
1.786A
324.699
86.886%
1692
41.0
40.11°C
0.986
12.160V
4.994V
3.318V
5.034V
373.705
43.44°C
115.18V
6
27.186A
6.034A
6.013A
1.991A
389.709
86.652%
1692
41.0
40.87°C
0.989
12.137V
4.975V
3.283V
5.019V
449.738
44.79°C
115.17V
7
31.826A
7.058A
7.052A
2.196A
454.581
86.180%
1692
41.0
42.14°C
0.990
12.113V
4.958V
3.275V
5.002V
527.476
46.38°C
115.17V
8
36.500A
8.098A
8.103A
2.405A
519.615
85.542%
1692
41.0
42.89°C
0.993
12.088V
4.942V
3.257V
4.986V
607.440
47.88°C
115.17V
9
41.619A
8.631A
8.658A
2.410A
584.659
84.761%
1692
41.0
44.37°C
0.995
12.063V
4.928V
3.244V
4.975V
689.776
50.13°C
115.18V
10
46.500A
9.163A
9.190A
3.029A
649.512
83.612%
1692
41.0
45.56°C
0.996
12.039V
4.913V
3.231V
4.948V
776.817
51.91°C
115.18V
11
51.982A
9.182A
9.218A
3.035A
714.385
82.714%
1692
41.0
46.28°C
0.996
12.017V
4.904V
3.222V
4.939V
863.678
53.33°C
115.18V
CL1
0.094A
16.028A
16.002A
0.004A
132.463
78.754%
1692
41.0
43.46°C
0.984
12.189V
4.929V
3.268V
5.072V
168.199
49.16°C
115.19V
CL2
54.112A
1.004A
1.003A
1.002A
665.402
84.138%
1692
41.0
45.94°C
0.996
12.051V
4.980V
3.267V
5.011V
790.843
51.62°C
115.18V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.186A
0.494A
0.475A
0.195A
19.645
55.945%
1638
40.0
0.947
12.262V
5.075V
3.361V
5.124V
35.115
115.20V
2
2.406A
0.981A
0.981A
0.390A
39.733
69.108%
1650
40.2
0.970
12.251V
5.067V
3.356V
5.115V
57.494
115.19V
3
3.627A
1.474A
1.489A
0.586A
59.853
76.093%
1658
40.5
0.983
12.244V
5.060V
3.354V
5.105V
78.658
115.19V
4
4.837A
1.975A
1.967A
0.780A
79.739
79.338%
1677
40.8
0.977
12.237V
5.054V
3.351V
5.098V
100.505
115.19V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.7 mV
10.1 mV
21.0 mV
11.2 mV
Pass
20% Load
7.1 mV
11.7 mV
23.3 mV
10.4 mV
Pass
30% Load
8.3 mV
10.1 mV
23.8 mV
11.6 mV
Pass
40% Load
9.2 mV
10.1 mV
25.4 mV
17.0 mV
Pass
50% Load
10.4 mV
11.5 mV
27.3 mV
12.8 mV
Pass
60% Load
12.4 mV
11.9 mV
28.8 mV
13.6 mV
Pass
70% Load
14.5 mV
11.7 mV
30.6 mV
14.1 mV
Pass
80% Load
15.8 mV
13.9 mV
33.6 mV
16.6 mV
Pass
90% Load
17.3 mV
15.8 mV
36.3 mV
19.2 mV
Pass
100% Load
20.1 mV
16.5 mV
40.9 mV
27.0 mV
Pass
110% Load
22.5 mV
16.2 mV
38.8 mV
26.7 mV
Pass
Crossload 1
16.1 mV
17.8 mV
48.6 mV
16.6 mV
Pass
Crossload 2
20.0 mV
12.6 mV
25.0 mV
15.8 mV
Pass
The results above are not used in the certification process