This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.214
70.164%
0.043
5.105V
0.305
115.14V
2
0.088A
0.447
76.150%
0.081
5.104V
0.587
115.14V
3
0.542A
2.763
79.671%
0.290
5.094V
3.468
115.13V
4
1.002A
5.097
79.865%
0.352
5.085V
6.382
115.14V
5
1.502A
7.619
78.312%
0.385
5.074V
9.729
115.14V
6
3.001A
15.136
75.714%
0.432
5.043V
19.991
115.13V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.361A
1.984A
1.947A
0.986A
74.789
77.842%
1505
41.1
38.02°C
0.966
12.199V
5.039V
3.385V
5.072V
96.078
41.52°C
115.17V
2
9.761A
2.981A
2.929A
1.186A
149.750
84.404%
1616
43.2
38.31°C
0.980
12.179V
5.024V
3.379V
5.057V
177.421
42.28°C
115.20V
3
15.523A
3.497A
3.438A
1.385A
224.896
86.285%
1664
43.8
38.80°C
0.979
12.162V
5.013V
3.371V
5.043V
260.642
43.24°C
115.18V
4
21.293A
3.998A
3.922A
1.591A
299.748
86.850%
1744
45.4
39.13°C
0.977
12.143V
5.002V
3.363V
5.028V
345.132
44.26°C
115.19V
5
26.748A
5.012A
4.914A
1.790A
374.699
86.836%
1758
45.8
39.78°C
0.983
12.122V
4.986V
3.356V
5.016V
431.500
45.97°C
115.21V
6
32.213A
6.039A
5.906A
2.000A
449.631
86.486%
1765
45.8
40.72°C
0.987
12.102V
4.970V
3.349V
4.998V
519.891
48.37°C
115.44V
7
37.706A
7.063A
6.908A
2.205A
524.552
85.904%
1765
45.8
41.66°C
0.992
12.080V
4.955V
3.341V
4.983V
610.628
50.60°C
115.35V
8
43.224A
8.101A
7.914A
2.415A
599.552
85.099%
1765
45.8
43.07°C
0.995
12.057V
4.940V
3.334V
4.967V
704.535
53.83°C
115.18V
9
49.186A
8.630A
8.445A
2.420A
674.611
84.288%
1765
45.8
44.28°C
0.996
12.036V
4.928V
3.326V
4.955V
800.360
57.16°C
115.16V
10
54.908A
9.162A
8.952A
3.040A
749.414
83.444%
1765
45.8
45.09°C
0.996
12.015V
4.914V
3.316V
4.930V
898.101
59.85°C
115.16V
11
61.251A
9.178A
8.978A
3.048A
824.287
82.159%
1765
45.8
46.62°C
0.997
11.993V
4.905V
3.308V
4.917V
1003.283
63.02°C
115.18V
CL1
0.096A
18.031A
18.000A
0.004A
150.055
78.870%
1765
45.8
43.77°C
0.980
12.153V
4.922V
3.340V
5.048V
190.255
53.94°C
115.17V
CL2
61.936A
1.004A
1.001A
1.002A
758.140
83.566%
1768
45.8
45.64°C
0.996
12.026V
4.966V
3.306V
4.993V
907.240
59.08°C
115.18V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.193A
0.492A
0.469A
0.196A
19.652
55.556%
13.65
39.0
0.942
12.217V
5.057V
3.390V
5.096V
35.373
115.17V
2
2.415A
0.985A
0.970A
0.391A
39.735
68.779%
1392
39.1
0.954
12.209V
5.050V
3.388V
5.090V
57.772
115.17V
3
3.640A
1.478A
1.474A
0.590A
59.866
75.360%
1465
40.4
0.965
12.203V
5.045V
3.387V
5.082V
79.440
115.17V
4
4.852A
1.985A
1.948A
0.786A
79.769
78.957%
1475
40.6
0.968
12.198V
5.039V
3.385V
5.073V
101.028
115.18V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
11.0 mV
56.0 mV
37.2 mV
10.6 mV
Fail
20% Load
10.6 mV
49.4 mV
30.4 mV
9.9 mV
Pass
30% Load
11.0 mV
52.2 mV
34.6 mV
11.2 mV
Fail
40% Load
14.0 mV
50.1 mV
27.4 mV
14.9 mV
Fail
50% Load
12.2 mV
13.2 mV
25.1 mV
16.2 mV
Pass
60% Load
14.4 mV
32.7 mV
29.6 mV
19.2 mV
Pass
70% Load
16.7 mV
25.9 mV
32.7 mV
19.5 mV
Pass
80% Load
19.1 mV
27.7 mV
42.4 mV
20.8 mV
Pass
90% Load
23.2 mV
27.9 mV
47.6 mV
24.1 mV
Pass
100% Load
28.4 mV
31.4 mV
46.3 mV
29.3 mV
Pass
110% Load
31.9 mV
30.7 mV
56.2 mV
28.8 mV
Fail
Crossload 1
16.0 mV
21.9 mV
56.7 mV
16.8 mV
Fail
Crossload 2
26.9 mV
44.1 mV
38.2 mV
20.9 mV
Pass
The results above are not used in the certification process
EVGA 750 BQ
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted