ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: Partially
ErP Lot 3/6 2014, CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
Efficiency Rating
BRONZE
Noise Rating
Standard++
Average Efficiency (>1450 load combinations)
84.685%
Average Noise Output (>1450 Load Combinations)
31.66dBA
Average PF (>1450 Load Combinations)
0.990
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1307W
12V Ripple (Full Load)
17.16mV
5V Ripple (Full Load)
16.73mV
3.3V Ripple (Full Load)
18.03mV
5VSB Ripple (Full Load)
27.33mV
12V Load Regulation
0.79%
5V Load Regulation
0.97%
3.3V Load Regulation
1.20%
5VSB Load Regulation
4.77%
Inrush Current
43.751A
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
22.66
AC Loss to PWR_OK Hold Up Time (ms)
20.14
PWR_OK Inactive to DC Loss Delay (ms)
2.52
Vampire Power
Tables 115V
Graphs 115V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.213
55.039%
0.030
5.124V
0.387
115.16V
2
0.087A
0.446
66.468%
0.052
5.122V
0.671
115.16V
3
0.542A
2.765
76.806%
0.228
5.100V
3.600
115.16V
4
1.002A
5.087
77.723%
0.327
5.077V
6.545
115.16V
5
1.502A
7.586
77.901%
0.386
5.052V
9.738
115.16V
6
3.001A
14.911
76.049%
0.465
4.969V
19.607
115.16V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.385A
1.984A
1.984A
0.985A
74.767
78.388%
0
<6.0
45.17°C
0.956
12.127V
5.050V
3.320V
5.060V
95.381
38.14°C
115.19V
2
9.808A
2.971A
2.981A
1.188A
149.737
82.908%
1180
26.7
40.01°C
0.982
12.120V
5.044V
3.317V
5.042V
180.607
43.56°C
115.19V
3
15.583A
3.479A
3.496A
1.391A
224.879
85.474%
1218
27.3
40.19°C
0.989
12.114V
5.039V
3.314V
5.025V
263.096
43.85°C
115.20V
4
21.355A
3.977A
3.983A
1.595A
299.740
86.755%
1240
27.8
40.40°C
0.992
12.107V
5.035V
3.311V
5.005V
345.503
44.09°C
115.19V
5
26.802A
4.974A
4.986A
1.803A
374.721
86.934%
1315
30.4
40.85°C
0.994
12.097V
5.030V
3.307V
4.985V
431.041
44.67°C
115.19V
6
32.255A
5.975A
5.991A
2.010A
449.621
86.672%
1425
32.3
41.39°C
0.995
12.086V
5.024V
3.303V
4.965V
518.762
45.34°C
115.19V
7
37.723A
6.982A
6.996A
2.222A
524.620
86.079%
1518
35.4
42.14°C
0.996
12.075V
5.019V
3.300V
4.944V
609.464
46.49°C
115.22V
8
43.204A
7.984A
8.010A
2.435A
599.523
85.391%
1645
37.4
42.86°C
0.996
12.062V
5.012V
3.295V
4.923V
702.091
47.54°C
115.19V
9
49.128A
8.487A
8.535A
2.440A
674.581
84.523%
1796
41.4
44.65°C
0.996
12.050V
5.009V
3.292V
4.910V
798.101
49.49°C
115.19V
10
54.814A
9.002A
9.050A
3.078A
749.458
83.619%
1910
42.1
45.68°C
0.996
12.036V
5.004V
3.281V
4.866V
896.273
50.81°C
115.19V
11
61.100A
9.012A
9.065A
3.085A
824.374
82.633%
2014
43.1
47.08°C
0.997
12.024V
4.998V
3.275V
4.855V
997.629
52.48°C
115.18V
CL1
0.098A
14.027A
14.003A
0.004A
117.483
75.801%
1425
32.3
44.06°C
0.977
12.119V
5.027V
3.268V
5.087V
154.989
47.72°C
115.20V
CL2
62.446A
1.003A
1.002A
1.002A
764.673
83.995%
1945
42.1
46.78°C
0.997
12.032V
5.013V
3.287V
4.991V
910.382
51.70°C
115.19V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.195A
0.492A
0.480A
0.195A
19.656
67.380%
0
<6.0
0.838
12.191V
5.068V
3.324V
5.124V
29.172
115.22V
2
2.418A
0.981A
0.990A
0.391A
39.717
77.905%
0
<6.0
0.909
12.183V
5.066V
3.323V
5.113V
50.981
115.21V
3
3.645A
1.478A
1.500A
0.585A
59.843
82.078%
0
<6.0
0.953
12.178V
5.064V
3.323V
5.101V
72.910
115.21V
4
4.862A
1.976A
1.985A
0.785A
79.773
84.254%
0
<6.0
0.965
12.172V
5.062V
3.322V
5.091V
94.681
115.21V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.0 mV
6.5 mV
11.4 mV
14.0 mV
Pass
20% Load
9.2 mV
6.6 mV
11.2 mV
14.3 mV
Pass
30% Load
9.3 mV
7.5 mV
11.0 mV
13.8 mV
Pass
40% Load
10.6 mV
8.4 mV
11.7 mV
14.6 mV
Pass
50% Load
11.4 mV
10.2 mV
12.2 mV
15.2 mV
Pass
60% Load
13.0 mV
10.1 mV
13.7 mV
15.6 mV
Pass
70% Load
13.0 mV
11.4 mV
14.4 mV
17.8 mV
Pass
80% Load
13.8 mV
11.5 mV
14.9 mV
17.8 mV
Pass
90% Load
14.9 mV
13.2 mV
16.6 mV
21.8 mV
Pass
100% Load
17.2 mV
16.7 mV
18.0 mV
27.3 mV
Pass
110% Load
17.3 mV
17.0 mV
18.6 mV
29.8 mV
Pass
Crossload 1
8.9 mV
8.5 mV
9.7 mV
11.9 mV
Pass
Crossload 2
17.0 mV
14.7 mV
16.4 mV
25.0 mV
Pass
The results above are not used in the certification process
EVGA 750 B3
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted