This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.211
70.100%
0.030
5.080V
0.301
115.18V
2
0.087A
0.441
75.773%
0.057
5.079V
0.582
115.18V
3
0.542A
2.747
79.831%
0.264
5.067V
3.441
115.16V
4
1.002A
5.066
78.251%
0.371
5.056V
6.474
115.17V
5
1.501A
7.574
78.018%
0.428
5.045V
9.708
115.17V
6
2.501A
12.556
75.657%
0.484
5.020V
16.596
115.17V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.736A
1.966A
1.962A
0.991A
54.735
85.126%
537
10.3
38.25°C
0.952
12.121V
5.080V
3.355V
5.047V
64.299
43.75°C
115.21V
2
6.513A
2.949A
2.949A
1.191A
109.747
89.397%
537
10.3
38.65°C
0.982
12.113V
5.078V
3.352V
5.033V
122.763
44.70°C
115.21V
3
10.638A
3.448A
3.458A
1.390A
164.831
90.609%
537
10.3
38.97°C
0.988
12.105V
5.075V
3.349V
5.020V
181.914
46.13°C
115.20V
4
14.762A
3.945A
3.941A
1.595A
219.749
90.995%
537
10.3
39.51°C
0.991
12.096V
5.073V
3.347V
5.006V
241.495
47.61°C
115.20V
5
18.548A
4.938A
4.932A
1.801A
274.742
90.710%
537
10.3
40.18°C
0.991
12.089V
5.069V
3.344V
4.992V
302.880
49.38°C
115.20V
6
22.347A
5.924A
5.926A
2.005A
329.707
90.312%
537
10.3
41.04°C
0.992
12.079V
5.065V
3.340V
4.977V
365.077
51.97°C
115.19V
7
26.138A
6.919A
6.919A
2.214A
384.672
89.161%
597
13.3
42.28°C
0.992
12.073V
5.062V
3.338V
4.963V
431.470
53.56°C
115.20V
8
29.947A
7.904A
7.916A
2.424A
439.583
88.438%
854
21.2
43.64°C
0.992
12.062V
5.058V
3.334V
4.947V
497.051
56.02°C
115.19V
9
34.180A
8.415A
8.432A
2.426A
494.658
87.824%
1182
31.1
44.23°C
0.992
12.055V
5.055V
3.332V
4.940V
563.235
57.96°C
115.19V
10
38.378A
8.911A
8.921A
2.533A
549.514
87.135%
1278
32.8
45.30°C
0.993
12.046V
5.053V
3.329V
4.930V
630.650
59.21°C
115.19V
11
42.969A
8.918A
8.925A
2.537A
604.466
86.473%
1493
37.0
46.22°C
0.993
12.038V
5.050V
3.326V
4.921V
699.021
60.15°C
115.19V
CL1
0.098A
12.014A
12.006A
0.004A
102.120
84.083%
545
10.9
42.92°C
0.982
12.099V
5.063V
3.339V
5.042V
121.452
55.63°C
115.21V
CL2
45.783A
1.004A
1.002A
1.001A
565.745
87.943%
1317
33.9
45.21°C
0.993
12.064V
5.063V
3.341V
4.984V
643.308
58.48°C
115.19V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.202A
0.491A
0.474A
0.196A
19.662
74.621%
537
10.3
0.800
12.129V
5.085V
3.359V
5.072V
26.349
115.21V
2
2.431A
0.981A
0.982A
0.391A
39.736
83.238%
537
10.3
0.920
12.125V
5.081V
3.356V
5.065V
47.738
115.20V
3
3.664A
1.468A
1.486A
0.590A
59.839
86.624%
537
10.3
0.956
12.121V
5.080V
3.355V
5.057V
69.079
115.20V
4
4.884A
1.964A
1.966A
0.790A
79.742
88.263%
537
10.3
0.971
12.118V
5.079V
3.354V
5.049V
90.346
115.20V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.2 mV
6.6 mV
7.8 mV
12.5 mV
Pass
20% Load
19.2 mV
7.6 mV
7.9 mV
11.3 mV
Pass
30% Load
22.6 mV
8.3 mV
8.7 mV
14.9 mV
Pass
40% Load
23.0 mV
9.5 mV
10.0 mV
13.9 mV
Pass
50% Load
24.4 mV
10.0 mV
9.2 mV
14.9 mV
Pass
60% Load
26.0 mV
10.3 mV
9.3 mV
15.6 mV
Pass
70% Load
27.5 mV
11.5 mV
10.0 mV
24.9 mV
Pass
80% Load
30.7 mV
13.3 mV
10.7 mV
23.7 mV
Pass
90% Load
31.0 mV
13.2 mV
17.7 mV
24.8 mV
Pass
100% Load
32.7 mV
16.9 mV
22.0 mV
21.5 mV
Pass
110% Load
32.7 mV
18.5 mV
23.9 mV
22.0 mV
Pass
Crossload 1
27.7 mV
13.5 mV
8.8 mV
10.7 mV
Pass
Crossload 2
26.0 mV
17.8 mV
21.8 mV
24.0 mV
Pass
The results above are not used in the certification process