ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: ✓
ErP Lot 3/6 2014, CEC: Partially
✓
Performance Summary 115V
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A++
(>1450 load combinations)
90.337%
Average Noise Output (>1450 Load Combinations)
13.45dBA
(>1450 Load Combinations)
0.979
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
0.0987W
12V Ripple (Full Load)
22.38mV
5V Ripple (Full Load)
0.00mV
3.3V Ripple (Full Load)
0.00mV
5VSB Ripple (Full Load)
27.13mV
12V Load Regulation
0.49%
5V Load Regulation
0.00%
3.3V Load Regulation
0.00%
5VSB Load Regulation
2.39%
Inrush Current
31.657A
Stromverbrauch im Ruhezustand
Tables 115V
Graphs 115V
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Supplementary Tests (For Reference)
115V
The results above are not used in the certification process
115V
The results above are not used in the certification process
115V
The results above are not used in the certification process
Aerocool ACP-650FP7
Top side
Power specifications label
ybenetics bietet die freiwilligen ETA- und Lambda-Zertifizierungsprogramme an, mit denen effiziente und leise Netzteile (PSU) beworben werden