ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: ✓
ErP Lot 3/6 2014, CEC: Partially
符合(EU) No 617/2013规范
✓
Performance Summary 115V
效率等级
PLATINUM
噪音等级
A++
平均效率 (>1450 load combinations)
90.337%
Average Noise Output (>1450 Load Combinations)
13.45dBA
PF平均值 (>1450 Load Combinations)
0.979
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
待机功率耗损
0.0987W
12V Ripple (Full Load)
22.38mV
5V Ripple (Full Load)
0.00mV
3.3V Ripple (Full Load)
0.00mV
5VSB Ripple (Full Load)
27.13mV
12V Load Regulation
0.49%
5V Load Regulation
0.00%
3.3V Load Regulation
0.00%
5VSB Load Regulation
2.39%
Inrush Current
31.657A
保持时间 & PG信号
待机电源
Tables 115V
Graphs 115V
资讯
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
转换效率图表
115V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
噪音值图表
115V
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 115V
Supplementary Tests (For Reference)
10-110%负载测试 115V
The results above are not used in the certification process
20-80瓦负载测试 115V
The results above are not used in the certification process
纹波测量 115V