This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
转换效率图表
115V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
噪音值图表
115V
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 115V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.041A
0.205
60.472%
0.014
4.945V
0.339
115.15V
2
0.087A
0.429
68.203%
0.027
4.942V
0.629
115.18V
3
0.542A
2.671
80.622%
0.134
4.929V
3.313
115.16V
4
1.002A
4.926
82.168%
0.224
4.918V
5.995
115.16V
5
1.502A
7.362
82.028%
0.302
4.903V
8.975
115.17V
6
3.001A
14.583
80.877%
0.436
4.859V
18.031
115.17V
Supplementary Tests (For Reference)
10-110%负载测试 115V
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
风扇噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
1
8.064A
1.976A
1.963A
0.991A
119.757
91.252%
870
25.1
38.22°C
0.944
12.174V
5.063V
3.359V
5.032V
131.237
41.20°C
115.18V
2
17.164A
2.961A
2.948A
1.190A
239.599
93.462%
870
25.1
38.51°C
0.972
12.162V
5.060V
3.354V
5.025V
256.359
41.96°C
115.18V
3
26.641A
3.464A
3.461A
1.395A
359.797
93.817%
1165
33.6
38.93°C
0.980
12.150V
5.058V
3.349V
5.016V
383.511
43.51°C
115.18V
4
36.115A
3.955A
3.943A
1.595A
479.533
93.614%
1130
32.3
39.49°C
0.985
12.138V
5.055V
3.345V
5.007V
512.245
45.23°C
115.17V
5
45.272A
4.953A
4.938A
1.800A
599.480
92.957%
1745
43.2
39.93°C
0.987
12.126V
5.052V
3.340V
4.998V
644.902
46.50°C
115.17V
6
54.453A
5.945A
5.932A
2.000A
719.317
92.414%
2020
46.6
40.44°C
0.989
12.112V
5.049V
3.335V
4.991V
778.367
47.26°C
115.17V
7
63.652A
6.942A
6.934A
2.205A
839.296
91.296%
2225
49.0
41.40°C
0.991
12.100V
5.046V
3.330V
4.983V
919.316
48.75°C
115.17V
8
72.861A
7.933A
7.940A
2.410A
959.208
90.709%
2390
50.5
42.50°C
0.992
12.089V
5.043V
3.324V
4.976V
1057.459
50.67°C
115.18V
9
82.543A
8.443A
8.462A
2.410A
1079.260
90.150%
2480
51.5
43.50°C
0.993
12.074V
5.040V
3.320V
4.975V
1197.186
52.49°C
115.18V
10
91.973A
8.938A
8.956A
3.025A
1199.089
89.506%
2500
51.9
44.89°C
0.993
12.062V
5.038V
3.316V
4.953V
1339.676
55.33°C
115.19V
11
102.024A
8.939A
8.965A
3.028A
1319.090
88.809%
2500
51.9
46.30°C
0.993
12.050V
5.036V
3.312V
4.951V
1485.318
58.08°C
115.20V
CL1
0.098A
14.024A
14.004A
0.004A
118.934
84.148%
2370
50.3
44.10°C
0.945
12.171V
5.058V
3.341V
5.089V
141.339
48.42°C
115.20V
CL2
99.934A
1.005A
1.001A
1.002A
1219.227
89.683%
2500
51.9
45.34°C
0.993
12.066V
5.042V
3.330V
5.013V
1359.491
55.65°C
115.20V
The results above are not used in the certification process
20-80瓦负载测试 115V
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
风扇噪音 (dB[A])
PF/AC 电压
1
1.200A
0.493A
0.474A
0.195A
19.688
66.413%
870
25.1
0.734
12.175V
5.065V
3.364V
5.059V
29.645
115.19V
2
2.421A
0.977A
0.980A
0.396A
39.721
70.264%
870
25.1
0.865
12.175V
5.065V
3.363V
5.052V
56.531
115.20V
3
3.644A
1.478A
1.483A
0.590A
59.837
85.090%
870
25.1
0.898
12.182V
5.064V
3.361V
5.045V
70.322
115.19V
4
4.860A
1.970A
1.961A
0.791A
79.742
88.313%
870
25.1
0.920
12.179V
5.064V
3.360V
5.040V
90.295
115.18V
The results above are not used in the certification process
纹波测量 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.8 mV
11.0 mV
9.2 mV
7.3 mV
Pass
20% Load
23.0 mV
12.4 mV
11.8 mV
9.7 mV
Pass
30% Load
28.9 mV
14.5 mV
13.5 mV
10.8 mV
Pass
40% Load
34.0 mV
15.3 mV
14.2 mV
12.0 mV
Pass
50% Load
43.2 mV
17.3 mV
16.2 mV
14.6 mV
Pass
60% Load
50.5 mV
18.4 mV
17.2 mV
14.9 mV
Pass
70% Load
59.2 mV
27.8 mV
28.9 mV
23.7 mV
Pass
80% Load
63.3 mV
23.5 mV
25.6 mV
22.0 mV
Pass
90% Load
69.8 mV
26.1 mV
25.8 mV
22.6 mV
Pass
100% Load
77.6 mV
29.4 mV
30.3 mV
25.4 mV
Pass
110% Load
81.8 mV
30.7 mV
31.4 mV
25.6 mV
Pass
Crossload 1
27.0 mV
13.7 mV
14.1 mV
9.6 mV
Pass
Crossload 2
74.5 mV
30.2 mV
32.9 mV
25.3 mV
Pass
The results above are not used in the certification process